RAMPART CONSTRUCTION | B= | C | 05/16/2017 | Correction made | JUSTINL | JUSTINL | | B= | C | 5508304 |
RAMPART CONSTRUCTION | BFI | C | 05/16/2017 | | JUSTINL | JUSTINL | | BFI | C | 5508303 |
RAMPART CONSTRUCTION | B= | P | 05/01/2017 | repair garage common wall at garage door opener controls -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | BOBF | BOBF | | B= | P | 5492565 |
RAMPART CONSTRUCTION | BTR | C | 12/06/2016 | | DAKOTAB | DAKOTAB | | BTR | C | 5361705 |
RAMPART CONSTRUCTION | BIN | C | 11/29/2016 | | BOBF | BOBF | | BIN | C | 5354480 |
RAMPART CONSTRUCTION | BIN | R | 11/28/2016 | need air barriers at shower and fireplace walls | BOBF | BOBF | | BIN | R | 5354416 |
RAMPART CONSTRUCTION | BFR | C | 11/17/2016 | Items corrected -- OK to insulate | DAKOTAB | DAKOTAB | | BFR | C | 5347540 |
RAMPART CONSTRUCTION | BFR | P | 11/16/2016 | Trip fee waved one time -- Still missing roof jacks -- Missing 3x3 nailing grad at all narrow braced walls -- Need to strap (5) 2x6 post next to steel post where electrical wires were notched in | DAKOTAB | DAKOTAB | | BFR | P | 5346382 |
RAMPART CONSTRUCTION | BFN | C | 11/15/2016 | letter for steel and eufer on file | BOBF | BOBF | | BFN | C | 5344201 |
RAMPART CONSTRUCTION | BFT | C | 11/15/2016 | open hole, design and letter for footing on file | BOBF | BOBF | | BFT | C | 5344199 |
RAMPART CONSTRUCTION | BFR | R | 11/14/2016 | garage narrow walls covered wit lath / fire block stud bays greater than 10' / plans call for 5" sch 40 monoposts, 3 1/2" monoposts installed / strap all top plates at vaulted ballon walls / missing pipe jacks / no insulation | BOBF | BOBF | | BFR | R | 5344120 |
RAMPART CONSTRUCTION | BLA | C | 11/04/2016 | At final, verify weep screed is 1/2" above any poured surface | DAKOTAB | DAKOTAB | | BLA | C | 5337026 |
RAMPART CONSTRUCTION | BFI | P | 08/09/2016 | 2" foam insulaton OK -- Foundation design received -- Still need all foundation engineering and open hole | DAKOTAB | DAKOTAB | | BFI | P | 5265258 |
RAMPART CONSTRUCTION | BFT | P | 07/06/2016 | AUTHORIZED INSPECTION BY ENGINEER | REBECCA | REBECCA | REBECCA | BFT | P | 5238403 |
RAMPART CONSTRUCTION | BFN | P | 07/06/2016 | AUTHORIZED INSPECTION BY ENGINEER | REBECCA | REBECCA | REBECCA | BFN | P | 5238402 |
A N' M ELECTRIC | EP | C | 04/28/2017 | 70 amp 4/w to sub panel ok | CRAIG | CRAIG | | EP | C | 5489971 |
A N' M ELECTRIC | E= | C | 04/28/2017 | | CRAIG | CRAIG | | E= | C | 5489960 |
A N' M ELECTRIC | E= | R | 04/27/2017 | bad gfci for exterior outlets, need 2 pole 20 for elevator and 15 for cab lights, provide means to check OH door outlets-----------20 amp a/c installed | MATTHEW | MATTHEW | | E= | R | 5489224 |
A N' M ELECTRIC | ES | C | 04/27/2017 | Residential Underground: 200 amp 3/w: new res------ meter is set; need seal | MATTHEW | MATTHEW | | ES | C | 5489202 |
A N' M ELECTRIC | ES | R | 11/22/2016 | Residential Underground: need to bond neutral | TOMC | TOMC | | ES | R | 5351661 |
A N' M ELECTRIC | EUG | C | 11/22/2016 | 250 urd | TOMC | TOMC | | EUG | C | 5351630 |
A N' M ELECTRIC | ER | C | 11/04/2016 | garage with living space above | TOMC | TOMC | | ER | C | 5337052 |
A & Z MECHANICAL, INC. | H= | C | 04/27/2017 | NOTES: AC complete. Boiler termination complete. | ACE | ACE | | H= | C | 5489108 |
A & Z MECHANICAL, INC. | HC | C | 11/10/2016 | RELEASE METER | MICHAELS | MICHAELS | | HC | C | 5342066 |
A & Z MECHANICAL, INC. | HRR | C | 11/10/2016 | Correction made. | MICHAELS | MICHAELS | | HRR | C | 5342055 |
A & Z MECHANICAL, INC. | HRR | P | 11/09/2016 | Open wire and plumbing in return air, rest ok. Note: air handler for a/c only, radiant heat. | MICHAELS | MICHAELS | | HRR | P | 5340683 |
R AND D PLUMBING | HO | C | 11/09/2016 | 10# test ok. 1" poly from future meter location to structure "B". BY FINAL: need 2lb. letter on file and labels. | MICHAELS | MICHAELS | | HO | C | 5340677 |
A & Z MECHANICAL, INC. | HRR | L | 11/08/2016 | No access, wet concrete. | MICHAELS | MICHAELS | | HRR | L | 5339439 |
R AND D PLUMBING | HWP | C | 11/07/2016 | 60# test ok. Upper level zones on building "B". | MICHAELS | MICHAELS | | HWP | C | 5338419 |
R AND D PLUMBING | HI | C | 10/31/2016 | 10# test ok. Sizing ok provided meter or 2lb. line at structure. 1 1/2" main to boiler, range, fp, bbq. Note: building "B" only. | MICHAELS | MICHAELS | | HI | C | 5332098 |
R AND D PLUMBING | HI | P | 10/28/2016 | Need boiler load to size gas line. | MICHAELS | MICHAELS | | HI | P | 5331131 |
R AND D PLUMBING | HI | R | 10/27/2016 | No access, structure is locked-no code given. | MICHAELS | MICHAELS | | HI | R | 5329700 |
R AND D PLUMBING | HWP | P | 08/24/2016 | 60# test ok. Under slab only. | MICHAELS | MICHAELS | | HWP | P | 5277133 |
R AND D PLUMBING | P= | C | 04/28/2017 | Corrections made.Certification of potable water to scanning. | CRADE | CRADE | | P= | C | 5490173 |
R AND D PLUMBING | P= | P | 04/27/2017 | Need to eliminate yard hydrant,Need aav at mech room floor drain,Need hammer arrestor for dish washer,Need certificate of potable water. | CRADE | CRADE | | P= | P | 5489072 |
R AND D PLUMBING | PTO | C | 10/17/2016 | NOTE : BUILDING B ONLY , AAV AT FD AND KITCHEN AND SINK . NO IRRIGATION , GARAGE DRAINS TO DAYLIGHT | GABE | GABE | | PTO | C | 5320164 |
HOMEOWNER | PWO | C | 10/11/2016 | by final--need back flow protection for yard hydrant, need certificate of potable water, will need another pwo inspection when main house is built (this is just for the pwo to building ''b'' only) | TED | TED | | PWO | C | 5315983 |
R AND D PLUMBING | PB | C | 08/17/2016 | H2O RUN UNDER FOOTER , FLOOR DRAINS IN GARAGE ARE RUN TO DAYLIGHT | GABE | GABE | | PB | C | 5271394 |