GE JOHNSON CONSTRUCTION COMPANY, INC. | B= | C | 10/04/2017 | last of phase 6-4 phase 4 okay, this completes all work for this permit. | NATHAN | NATHAN | | B= | C | 5644501 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFR | P | 08/31/2017 | above ceiling at room 4642,4689 in area 4B and area 4B above ceiling marking okay | NATHAN | NATHAN | | BFR | P | 5612687 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BSP | P | 08/15/2017 | firestopping wall penetration and putty pads at electric boxes below grid okay rooms 4642, 4689 area 4B | NATHAN | NATHAN | | BSP | P | 5595708 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | B= | P | 07/18/2017 | phase 3 ICU okay with completed final MEP's, above ceiling and marking okay -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): BERWICK ELECTRIC CO Electrical Final Inspection is not Completed yet, OLSON PLUMBING & HEATING CO Plumbing Final Inspection is not Completed yet. | NATHAN | NATHAN | | B= | P | 5567602 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFR | P | 05/24/2017 | previous walls inspected boxes putty pads ok/need above grid penetrations sealed and labeled | BERTW | BERTW | | BFR | P | 5515505 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BSP | P | 05/18/2017 | Training with Matt M on I-2 occupancies remodeling areas/Inspected storage rooms #4662 and 4652-putty pad all boxes in rated walls for incidental uses areas-remove cutin black ring boxes for low volt and use metal boxes-seal all penetrations and overlay sheetrock areas. | BERTW | BERTW | | BSP | P | 5510384 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | B= | P | 12/20/2016 | Phase #2 ok pending other final completed -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): BERWICK ELECTRIC CO Electrical Final Inspection is not Completed yet, OLSON PLUMBING & HEATING CO Plumbing Final Inspection is not Completed yet. | BERTW | BERTW | | B= | P | 5372719 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BSP | P | 12/07/2016 | Phase 4 D OK above ceiling and penetrations OK / Training with Nathan R on Hospital inspections, meeting point of contacts / | NICK | NICK | | BSP | P | 5362321 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BSP | P | 12/07/2016 | training with Nick for smoke barrier, limited scope pod D phase 4 | NATHAN | NATHAN | | BSP | P | 5362320 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | B= | P | 10/12/2016 | Phase 1 Building final OK / Need plumbing final complete for phase 1 -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): BERWICK ELECTRIC CO Electrical Final Inspection is not Completed yet, OLSON PLUMBING & HEATING CO Plumbing Final Inspection is not Completed yet. | NICK | NICK | | B= | P | 5316564 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BSP | P | 09/20/2016 | Phase #1 walls ok/penetrations sealed ok | BERTW | BERTW | | BSP | P | 5297811 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | E= | C | 09/20/2017 | | CRAIGS | CRAIGS | | E= | C | 5631120 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | ER | P | 09/06/2017 | above ceiling OK | CRAIGS | CRAIGS | | ER | P | 5616899 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | ER | P | 08/31/2017 | head walls | CRAIGS | CRAIGS | | ER | P | 5612548 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | ER | P | 08/11/2017 | in head wall last phase of the scope of work | CRAIGS | CRAIGS | | ER | P | 5592835 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | E= | P | 07/18/2017 | | CRAIGS | CRAIGS | | E= | P | 5567368 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | ER | P | 07/10/2017 | above ceiling OK | CRAIGS | CRAIGS | | ER | P | 5558598 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | ER | P | 06/19/2017 | head walls | CRAIGS | CRAIGS | | ER | P | 5539361 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | ER | P | 05/24/2017 | remainder of in wall | CRAIGS | CRAIGS | | ER | P | 5515289 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | ER | P | 05/17/2017 | rest of end walls and can lights in hard lids | CRAIGS | CRAIGS | | ER | P | 5508842 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | E= | P | 12/14/2016 | 4th floor icu OK | CRAIGS | CRAIGS | | E= | P | 5368110 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | ER | P | 12/01/2016 | 2nd phase above ceiling rooms and corridor ---OK | CRAIGS | CRAIGS | | ER | P | 5357273 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | ER | P | 11/17/2016 | 4th floor ICU --- OK | CRAIGS | CRAIGS | | ER | P | 5347102 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | ER | P | 11/03/2016 | nurses station walls | CRAIGS | CRAIGS | | ER | P | 5335128 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | ER | P | 10/31/2016 | last 6 rooms in head wall OK | CRAIGS | CRAIGS | | ER | P | 5331514 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | ER | P | 10/27/2016 | 4th floor ICU rooms 4668-4670-4672 head wall in wall OK | CRAIGS | CRAIGS | | ER | P | 5329452 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | E= | P | 10/12/2016 | phase one electrical and fire alarm -------OK | CRAIGS | CRAIGS | | E= | P | 5316388 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | E= | P | 10/05/2016 | see plans | CRAIGS | CRAIGS | | E= | P | 5310537 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | E= | C | 09/16/2016 | FIRE ALARM INSPECTION: ceiling ok | BRET | BRET | | E= | C | 5295049 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | ER | C | 09/16/2016 | FIRE ALARM INSPECTION: ceiling ok | BRET | BRET | | ER | C | 5295048 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | ER | C | 09/16/2016 | ceilings ok | BRET | BRET | | ER | C | 5295047 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | ER | P | 08/19/2016 | 6 head walls ---- 6 Isolation panels ----OK | CRAIGS | CRAIGS | | ER | P | 5273250 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | ER | P | 08/04/2016 | rooms 08,10,20 thru 26 in head wall rough OK | CRAIGS | CRAIGS | | ER | P | 5261451 |
OLSON PLUMBING & HEATING COMPANY | P= | C | 10/03/2017 | 4th floor complete. | TAYLOR | TAYLOR | | P= | C | 5643010 |
OLSON PLUMBING & HEATING COMPANY | P= | P | 07/18/2017 | rooms 4652 - 4662 and hallway sinks ok at 4th floor. | TAYLOR | TAYLOR | | P= | P | 5567534 |
OLSON PLUMBING & HEATING COMPANY | PTO | P | 05/31/2017 | rooms 4652 - 4662 ok for phase 2. | TAYLOR | TAYLOR | | PTO | P | 5520909 |
OLSON PLUMBING & HEATING COMPANY | P= | P | 12/08/2016 | rooms 4666 - 4676 ok for phase 2. | TAYLOR | TAYLOR | | P= | P | 5363171 |
OLSON PLUMBING & HEATING COMPANY | P= | P | 10/13/2016 | phase 1 complete | TED | TED | | P= | P | 5317530 |
OLSON PLUMBING & HEATING COMPANY | PTO | P | 08/12/2016 | phase 1 rooms 4608 to 4626 ok | TED | TED | | PTO | P | 5267865 |