ASPEN GOLD GENERAL CONTRACTING & ENGINEERING, LLC | B= | C | 01/26/2017 | | BOBF | BOBF | | B= | C | 5399363 |
ASPEN GOLD GENERAL CONTRACTING & ENGINEERING, LLC | BLA | C | 11/07/2016 | | BOBF | BOBF | | BLA | C | 5337856 |
ASPEN GOLD GENERAL CONTRACTING & ENGINEERING, LLC | BIN | C | 11/01/2016 | | BOBF | BOBF | | BIN | C | 5332966 |
ASPEN GOLD GENERAL CONTRACTING & ENGINEERING, LLC | BFR | P | 11/01/2016 | pending splice for pergola and door frame okay | BOBF | BOBF | | BFR | P | 5332953 |
ASPEN GOLD GENERAL CONTRACTING & ENGINEERING, LLC | BSP | T | 11/01/2016 | PAID (REC#1379491): PLAN SPLICE FEE: $50 by: DANM for Construction: Add door on garage workshop; add pergola over rear deck | DANM | DANM | | BSP | T | 5332948 |
ASPEN GOLD GENERAL CONTRACTING & ENGINEERING, LLC | BFR | R | 10/28/2016 | need to revise plans and splice for added door in shop and pergola on exterior / missing st 22 straps per note A / need strap to suuport landing both sides / need steel shims under beams in basement / glue shims in basement / tighten nuts on anchorbolts throughout / okay to insulate | BOBF | BOBF | | BFR | R | 5330719 |
ASPEN GOLD GENERAL CONTRACTING & ENGINEERING, LLC | BSP | R | 10/04/2016 | truss inspection part of frame inspection, need to complete plumb, mech and elec rough inspections | BOBF | BOBF | | BSP | R | 5309621 |
ASPEN GOLD GENERAL CONTRACTING & ENGINEERING, LLC | BSP | P | 09/27/2016 | garage narrow wall, front porch with posts, rear porch with posts and deck posts okay | BOBF | BOBF | | BSP | P | 5304080 |
ASPEN GOLD GENERAL CONTRACTING & ENGINEERING, LLC | BFI | C | 08/12/2016 | 2" R-10 Rigid | BOBF | BOBF | | BFI | C | 5267582 |
ASPEN GOLD GENERAL CONTRACTING & ENGINEERING, LLC | BFI | R | 08/11/2016 | reschek calls for R- 10, R 7.5 installed on entire floor, heat loss calcs show R-10 for entire floor area also, No rigid installed on walkout wall | BOBF | BOBF | | BFI | R | 5266984 |
ASPEN GOLD GENERAL CONTRACTING & ENGINEERING, LLC | BFD | C | 08/08/2016 | eng letter for drain observation on file | BOBF | BOBF | | BFD | C | 5263411 |
ASPEN GOLD GENERAL CONTRACTING & ENGINEERING, LLC | BFN | C | 08/05/2016 | eng letter for steel, eufer and exterior piers on file | BOBF | BOBF | | BFN | C | 5262347 |
ASPEN GOLD GENERAL CONTRACTING & ENGINEERING, LLC | BFT | C | 08/05/2016 | eng letter for footing, interior pads and exterior pads on file | BOBF | BOBF | | BFT | C | 5262338 |
ASPEN GOLD GENERAL CONTRACTING & ENGINEERING, LLC | BSP | P | 08/05/2016 | soils report on file | BOBF | BOBF | | BSP | P | 5262335 |
ASPEN GOLD GENERAL CONTRACTING & ENGINEERING, LLC | BSP | P | 08/05/2016 | open hole on file | BOBF | BOBF | | BSP | P | 5262332 |
ASPEN GOLD GENERAL CONTRACTING & ENGINEERING, LLC | BSP | P | 08/05/2016 | design on file | BOBF | BOBF | | BSP | P | 5262328 |
ASPEN GOLD GENERAL CONTRACTING & ENGINEERING, LLC | BFD | P | 07/19/2016 | AUTHORIZED INSPECTION BY ENGINEER | MINDY | MINDY | MINDY | BFD | P | 5248951 |
ASPEN GOLD GENERAL CONTRACTING & ENGINEERING, LLC | BFN | P | 07/19/2016 | AUTHORIZED INSPECTION BY ENGINEER | MINDY | MINDY | MINDY | BFN | P | 5248949 |
ASPEN GOLD GENERAL CONTRACTING & ENGINEERING, LLC | BFT | P | 07/19/2016 | AUTHORIZED INSPECTION BY ENGINEER | MINDY | MINDY | MINDY | BFT | P | 5248950 |
DUKES ELECTRIC, INC | EP | C | 01/12/2017 | all sub panels ok ----------- 22k generator ok ----------- transfer switch ok | CRAIG | CRAIG | | EP | C | 5387785 |
DUKES ELECTRIC, INC | E= | C | 01/12/2017 | 30 - amp A/C ok / hot tub pre wire | CRAIG | CRAIG | | E= | C | 5387762 |
DUKES ELECTRIC, INC | ES | C | 10/24/2016 | Residential Underground: 200-amp 3 Wire service, ok to seal meter / | CRAIG | CRAIG | | ES | C | 5325786 |
DUKES ELECTRIC, INC | ER | C | 10/24/2016 | no mcc 6 - 10/3 100 amp 4/w 1/0 al to sub panel in finished basement and 70 amp 4/w #2 al to sub panel feed from generator -------- 6/3 cu to hot tub 2 v- 8/3 cu to steamer / ac transfer switch ok cen vac installing 22 kw generator non irreversible | CRAIG | CRAIG | | ER | C | 5325782 |
DUKES ELECTRIC, INC | EUG | C | 08/23/2016 | 3/w 250 mcm al service lateral | CRAIG | CRAIG | | EUG | C | 5275387 |
ADEPT PLUMBING & HEATING LLC | H= | C | 01/13/2017 | Final inspection on new construction comes under the mechanical contractor, the plumbing contractor does not request a final. Call aheads are not for new construction. | MARK | MARK | | H= | C | 5389067 |
BROWN'S HEATING & COOLING, INC | H= | C | 01/13/2017 | Final ok. Note: Finished basement with hot water heat, direct vent boiler. 1- a/c in attic with secondary furnace, 80" vented attic. No outside air to return. Duct leak report received. | MARK | MARK | | H= | C | 5388755 |
ADEPT PLUMBING & HEATING LLC | HC | C | 10/27/2016 | RELEASE METER | MARK | MARK | | HC | C | 5329663 |
ADEPT PLUMBING & HEATING LLC | HI | C | 10/27/2016 | 10 lb test ok. Note: 1 1/2" main, furnace ( in attic) Boiler, range, future fire pit at deck future bbq stub at deck,lower level fireplace | MARK | MARK | | HI | C | 5329659 |
ADEPT PLUMBING & HEATING LLC | HV | C | 10/26/2016 | Framing has been added, rough ok. | MARK | MARK | | HV | C | 5328247 |
ADEPT PLUMBING & HEATING LLC | HV | P | 10/25/2016 | Need to back frame boiler vents on main level, rest ok. | MARK | MARK | | HV | P | 5327089 |
ADEPT PLUMBING & HEATING LLC | HWP | P | 10/25/2016 | 4 zones for main lvl ok. | MARK | MARK | | HWP | P | 5327040 |
ADEPT PLUMBING & HEATING LLC | HV | L | 10/21/2016 | What would you like me to inspect for you? Tried calling no answer. | MARK | MARK | | HV | L | 5325042 |
BROWN'S HEATING & COOLING, INC | HRR | C | 10/21/2016 | Unable to inspect boiler vents as they are not installed. Apparently they will be entirely accessible at final. | MARK | MARK | | HRR | C | 5324885 |
BROWN'S HEATING & COOLING, INC | HRR | P | 10/18/2016 | No boiler vents yet, need make up air to laundry by final. Note: Finished basement, Lower level fireplace frame and vent ok, Note: Need to inspect furnace in attic at final, secondary heat source no duct design. | MARK | MARK | | HRR | P | 5321205 |
ADEPT PLUMBING & HEATING LLC | HWP | P | 08/11/2016 | 3- zones in basement ok. Ok to cover all of basement. | MARK | MARK | | HWP | P | 5266803 |
ADEPT PLUMBING & HEATING LLC | P= | C | 01/19/2017 | NOTE : FINISHED BASEMENT , PVB INSTALLED . TEMPERING IN MASTER CLOSET , POTABLE WATER CERT TO SCANNING | GABE | GABE | | P= | C | 5392958 |
ADEPT PLUMBING & HEATING LLC | PTO | C | 10/25/2016 | NOTE : FINISHED BASEMENT , IRRIGATION , TEMPERING IN MASTER CLOSET , AAV AT KITCHEN ONLY , | GABE | GABE | | PTO | C | 5327212 |
HOMEOWNER | PWO | C | 08/29/2016 | H20 RUN UNDER FOOTER , NEED POTABLE WATER CERT BY FINAL | GABE | GABE | | PWO | C | 5280277 |
ADEPT PLUMBING & HEATING LLC | PB | C | 08/04/2016 | H2O RUN UNDER FOOTER | GABE | GABE | | PB | C | 5261743 |