CONSTRUCTION BY GENESIS, INC. | B= | C | 06/23/2017 | corrections from previous inspection okay / rear deck corrections noted from 3JAN17 okay | BRIANB | BRIANB | | B= | C | 5545354 |
CONSTRUCTION BY GENESIS, INC. | B= | R | 06/22/2017 | sheetrock garage attic access lid / exposed foam at rim at room attached to mech. room / insulate behind trunk line at mech. room | DALE | DALE | | B= | R | 5544397 |
CONSTRUCTION BY GENESIS, INC. | BSP | R | 04/13/2017 | Standard Bacteriological Water Test uploaded with inspection request - inspection needs to be requested with plumbing not a building request | BRIANB | BRIANB | | BSP | R | 5473675 |
CONSTRUCTION BY GENESIS, INC. | BLA | C | 02/14/2017 | | DAKOTAB | DAKOTAB | | BLA | C | 5415004 |
CONSTRUCTION BY GENESIS, INC. | BIN | C | 02/13/2017 | | JUSTINL | JUSTINL | | BIN | C | 5414036 |
CONSTRUCTION BY GENESIS, INC. | BIN | R | 02/09/2017 | missing insulation at master / fireblock drops at basement | DALE | DALE | | BIN | R | 5411700 |
CONSTRUCTION BY GENESIS, INC. | BFR | C | 02/09/2017 | | DALE | DALE | | BFR | C | 5411697 |
CONSTRUCTION BY GENESIS, INC. | BFR | P | 02/03/2017 | OK to insulate -- Missing anchor bolt at splice in garage -- Strong back both gable ends -- Deck frame to be called in as BSP per contractor -- Training with Noah | DAKOTAB | DAKOTAB | | BFR | P | 5406366 |
CONSTRUCTION BY GENESIS, INC. | BSP | P | 01/03/2017 | front porch posts ok, still need to nail deck hangers | DALE | DALE | | BSP | P | 5381366 |
CONSTRUCTION BY GENESIS, INC. | BSP | P | 12/19/2016 | front porch trusses okay, missing hardware at post to beam connections / rear porch and posts okay / rear deck needs joists nailed off to hangars | BOBF | BOBF | | BSP | P | 5371855 |
CONSTRUCTION BY GENESIS, INC. | BSP | P | 10/12/2016 | (4) rear deck piers okay
| BRIANB | BRIANB | | BSP | P | 5317214 |
CONSTRUCTION BY GENESIS, INC. | BFI | C | 09/28/2016 | 2" R10 okay | BRIANB | BRIANB | | BFI | C | 5305322 |
CONSTRUCTION BY GENESIS, INC. | BFD | C | 09/28/2016 | habitable only / daylights at west lower walkout walls / damp proof okay | BRIANB | BRIANB | | BFD | C | 5305320 |
CONSTRUCTION BY GENESIS, INC. | BFN | C | 09/28/2016 | Engineers observation Letter on file / Eufer OK / Foundation design on file / Soils report on file / 5000 psf / habitable drain | BRIANB | BRIANB | | BFN | C | 5305301 |
CONSTRUCTION BY GENESIS, INC. | BFT | C | 09/28/2016 | Engineers observation Letter on file | BRIANB | BRIANB | | BFT | C | 5305299 |
HOMERUN ELECTRONICS, INC. | E= | C | 06/21/2017 | | MATTHEW | MATTHEW | | E= | C | 5542949 |
HOMERUN ELECTRONICS, INC. | E= | T | 06/20/2017 | PAID (REC#1433148): locked 9:55 | MATTHEW | MATTHEW | | E= | T | 5540451 |
HOMERUN ELECTRONICS, INC. | E= | R | 06/19/2017 | outlet on upper deck by gas no power ( not working ) | CRAIG | CRAIG | | E= | R | 5539934 |
HOMERUN ELECTRONICS, INC. | E= | L | 06/16/2017 | locked 11:23 | MATTHEW | MATTHEW | | E= | L | 5537955 |
HOMERUN ELECTRONICS, INC. | E= | R | 06/14/2017 | gfci OH door outlet and outlet by OH doors, where's the garage 20 amp 220v, whip above oven not landed (looks like 220v connection and only 120v available), cover plate in entertainment center cut in half; rest of box closed by combustible wood of entertainment center, missing smoke in exercise room, basement bedroom light/fan not working, gfci outlets in unfinished area behind door, outlet on upper deck by gas not working---------- hot tub and a/c pre-wires only---------- garage heater not installed | MATTHEW | MATTHEW | | E= | R | 5535301 |
HOMERUN ELECTRONICS, INC. | ER | C | 02/01/2017 | | MATTHEW | MATTHEW | | ER | C | 5403965 |
HOMERUN ELECTRONICS, INC. | ES | C | 01/31/2017 | Residential Underground: 200 amp 3/w: new res----- meter is set; need seal | MATTHEW | MATTHEW | | ES | C | 5403277 |
HOMERUN ELECTRONICS, INC. | ER | R | 01/31/2017 | seal return air where nm runs thru at hall by master and by both bedrooms in basement, run conduit from thermostat to floor for master bath floor heat------------ finished basement, no mcc's, no vac, ir ufer, #6mc to hot tub | MATTHEW | MATTHEW | | ER | R | 5403265 |
HOMERUN ELECTRONICS, INC. | ER | L | 01/30/2017 | locked 12:40 | MATTHEW | MATTHEW | | ER | L | 5401675 |
HOMERUN ELECTRONICS, INC. | EUG | C | 10/13/2016 | 250 al service lateral from ped to house | MATTHEW | MATTHEW | | EUG | C | 5318239 |
IMS HEATING & AIR, INC. | H= | C | 06/02/2017 | NO GARAGE UNIT HEATER OR VENT IS INSTALLED (WILL NEED SEPARATE PERMIT TO GARAGE UNIT HEATER WHEN INSTALLED). note: finished basement, high/low combustion air to mechanical room, 6" outside air to return, direct vent furnace with zoned system, a/c rough and line set. | PAULO | PAULO | | H= | C | 5524260 |
CORNERSTONE PLUMBING INC | HC | C | 01/17/2017 | OK TO SET METER. | NANCY | NANCY | | HC | C | 5390998 |
CORNERSTONE PLUMBING INC | HI | C | 01/17/2017 | 10 LB TEST OK. 1 1/4 INCH LINE IN. 1 FURNACE, 2 WATER HEATERS, 1 COOKTOP, 1 BBQ (DECK) 1 GARAGE HEATER. GARAGE HEATER CAN NOT BE MORE THAN 40,000 BTU'S WHEN INSTALLED. | NANCY | NANCY | | HI | C | 5390996 |
CORNERSTONE PLUMBING INC | HI | L | 01/13/2017 | Home is locked. | JEFFL | JEFFL | | HI | L | 5389017 |
IMS HEATING & AIR, INC. | HRR | C | 01/11/2017 | ***1'' clearance required to wood framing from b vent in mech room by final***. Rest ok. Notes-- OSA to return. Duct design. Finished basement. Direct vent furnace. | JEFFL | JEFFL | | HRR | C | 5386658 |
CORNERSTONE PLUMBING INC | P= | C | 06/08/2017 | Note:finished basement,RP out side for irrigation. | CRADE | CRADE | | P= | C | 5529738 |
CORNERSTONE PLUMBING INC | P= | P | 03/01/2017 | certificate of potable water to scanning | TED | TED | | P= | P | 5427684 |
CORNERSTONE PLUMBING INC | PTO | C | 01/13/2017 | finished basement, aav basement bedroom bathroom lav | TED | TED | | PTO | C | 5388965 |
CORNERSTONE PLUMBING INC | PB | C | 10/10/2016 | corrections made | TIM | TIM | | PB | C | 5313901 |
HOMEOWNER | PWO | C | 10/07/2016 | | TIM | TIM | | PWO | C | 5313135 |
CORNERSTONE PLUMBING INC | PB | P | 10/07/2016 | piping cant be on mounded dirt it needs to be in a ditch | TIM | TIM | | PB | P | 5313125 |