COLORADO COMMERCIAL CONSTRUCTION, INC. | B= | C | 12/20/2016 | final OK pending other finals / training with Justin L | DANE | DANE | | B= | C | 5372632 |
COLORADO COMMERCIAL CONSTRUCTION, INC. | BFR | P | 12/09/2016 | interior framing OK pending other roughs / discussed accessible elements with contractor including service counter having a height of no higher than 36" and a length of at least 36" with a parallel approach | DANE | DANE | | BFR | P | 5364824 |
EL PASO ELECTRIC, LLC. | E= | C | 12/14/2016 | | BRET | BRET | | E= | C | 5367801 |
EL PASO ELECTRIC, LLC. | ER | C | 11/16/2016 | counter walls ok r | BRET | BRET | | ER | C | 5346148 |
EL PASO ELECTRIC, LLC. | ER | P | 11/02/2016 | walls and hard lid | BRET | BRET | | ER | P | 5334516 |
EL PASO ELECTRIC, LLC. | ESL | C | 10/10/2016 | slab unit #100 3/4" and 1" pvc | TOMC | TOMC | | ESL | C | 5314716 |
LANDMARK PLUMBING AND HEATING, INC. | H= | C | 12/20/2016 | GAS/WATER HEATER VENT FINAL OK. | NANCY | NANCY | | H= | C | 5372563 |
NIELSEN MECHANICAL CONTRACTORS, INC. | H= | C | 12/15/2016 | MECHANICAL FINAL OK. | NANCY | NANCY | | H= | C | 5369028 |
NIELSEN MECHANICAL CONTRACTORS, INC. | H= | P | 12/15/2016 | REVISED TEST AND BALANCE REPORT RECEIVED. | NANCY | NANCY | | H= | P | 5368701 |
LANDMARK PLUMBING AND HEATING, INC. | HV | C | 12/13/2016 | WATER HEATER VENT OK. | NANCY | NANCY | | HV | C | 5367149 |
LANDMARK PLUMBING AND HEATING, INC. | HC | C | 12/12/2016 | 210,000 BTU'S ADDED TO EXISTING METER. | NANCY | NANCY | | HC | C | 5365451 |
LANDMARK PLUMBING AND HEATING, INC. | HI | C | 12/12/2016 | ADD WATER HEATER VENT ONTO SCOPE OF WORK AND CALL FOR INSPECTION WHEN READY. 10 LB TEST OK. INSTALLED AS PER PRINTS. COMPLETE CONNECTION TO RTU BY FINAL. | NANCY | NANCY | | HI | C | 5365445 |
NIELSEN MECHANICAL CONTRACTORS, INC. | H= | P | 12/09/2016 | SCREEN EXHAUST TERMINATIONS ON ROOF. PROVIDE TEST AND BALANCE REPORT WITH EXHAUST READINGS. | NANCY | NANCY | | H= | P | 5364693 |
NIELSEN MECHANICAL CONTRACTORS, INC. | H= | P | 12/09/2016 | TEST AND BALANCE REPORT RECEIVED, LACKS EXHAUST FAN READINGS. | NANCY | NANCY | | H= | P | 5364031 |
NIELSEN MECHANICAL CONTRACTORS, INC. | HD | P | 11/01/2016 | CONTRACTOR INSTALLING WATER HEATER VENT NEEDS TO ADD IT TO THEIR SCOPE OF WORK AND CALL FOR INSPECTION WHEN READY. SUPPLIES AND EXHAUST ABOVE HARD LIDS OK. EXPOSED DUCTS OK. NO DIFFUSERS OR ROOF TODAY. INSTALL CO2 SENSOR AS PER PRINTS BY FINAL. | NANCY | NANCY | | HD | P | 5333692 |
LANDMARK PLUMBING AND HEATING, INC. | P= | C | 12/14/2016 | CORRECTIONS MADE. | GABE | GABE | | P= | C | 5368058 |
LANDMARK PLUMBING AND HEATING, INC. | P= | P | 12/13/2016 | NEED TO TIE IN DRAIN FROM COFFEE TO BARBED TAIL PIECE , NEED ALL CHECKS INSTALLED AT WATER CONNECTED APPLIANCES , SECURE AND CAULK ALL SINKS , REST OK | GABE | GABE | | P= | P | 5367020 |
LANDMARK PLUMBING AND HEATING, INC. | PTO | C | 11/01/2016 | ALL SINKS ARE TEMPERED , HAMMER ARRESTERS IN PLACE , ALL TO PLAN | GABE | GABE | | PTO | C | 5333034 |
LANDMARK PLUMBING AND HEATING, INC. | PB | C | 10/04/2016 | NOTE : GREASE AND SANITARY ON TEST , TO PLAN | GABE | GABE | | PB | C | 5309929 |
LANDMARK PLUMBING AND HEATING, INC. | PB | R | 09/30/2016 | NO PLAN IMAGES AVAILABLE , CHECK APPROVAL BY RBD , DOOR LOCKED , NO CALL AHEAD | GABE | GABE | | PB | R | 5307333 |