GOEBEL CONSTRUCTION, INC | B= | C | 05/17/2017 | | BOBF | BOBF | | B= | C | 5509848 |
GOEBEL CONSTRUCTION, INC | B= | P | 05/15/2017 | provide stairs and landing off master bedroom, door is currently guarded, rest of house okay -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | BOBF | BOBF | | B= | P | 5507031 |
GOEBEL CONSTRUCTION, INC | BIN | C | 02/28/2017 | | DAKOTAB | DAKOTAB | | BIN | C | 5427595 |
GOEBEL CONSTRUCTION, INC | BFR | C | 02/28/2017 | Items corrected -- Engineer letter for added windows received | DAKOTAB | DAKOTAB | | BFR | C | 5427592 |
GOEBEL CONSTRUCTION, INC | BLA | C | 02/27/2017 | | DAKOTAB | DAKOTAB | | BLA | C | 5426437 |
GOEBEL CONSTRUCTION, INC | BFR | R | 02/23/2017 | need to complete plumbing for master sink, and get reinspected by plumbing, will verify vent will not go through 5 member post after plumbing is completed, still need letter for window | BOBF | BOBF | | BFR | R | 5423677 |
GOEBEL CONSTRUCTION, INC | BFR | R | 02/22/2017 | Field canceled by contractor on site | DAKOTAB | DAKOTAB | | BFR | R | 5421265 |
GOEBEL CONSTRUCTION, INC | BIN | R | 02/21/2017 | framing items not completed, no inspection, will also need eng letter for 5 member post with 2 1/2" hole drilled all the way through as well as support for post in crawlspace, please note insulation was not okayed and vent jack was not completed, was installed on top of shingles and not laced in | BOBF | BOBF | | BIN | R | 5420876 |
GOEBEL CONSTRUCTION, INC | BFR | R | 02/10/2017 | Still missing roof jacks at bath fan and at kitchen range vent -- Still missing LUS28 at first F02 -- Window at rear of great room calls for (4) king studs and ST18 at middle packs of (3) trimmer -- Window at side of great room calls for (3) kings at each side -- Front window at dining room calls for (4) kings and ST18 on middle pack of (3) trimmers -- Missing (2) 2x6 post and (2) H2.5's on each end of girder truss B01 -- Missing truss bracing on B02 -- Missing (5) 2x4 post and (2) TBE4's at mid -point bearing for (2) LVL (Will need plumbing drain pipe reconnected at time of re-inspect) -- Missing all point loads in crawlspace -- Still need engineer letter for window added not shown on plans -- Verifiy all items are corrected before recalling inspection to avoid trip fee | DAKOTAB | DAKOTAB | | BFR | R | 5412102 |
GOEBEL CONSTRUCTION, INC | BSP | P | 02/09/2017 | Continuation of frame items -- Missing all point loads in crawl space -- Glue shims under steel beam in crawl space | DAKOTAB | DAKOTAB | | BSP | P | 5411030 |
GOEBEL CONSTRUCTION, INC | BFR | T | 02/09/2017 | PAID (REC#1401543) Still too many items -- Narrow braced wall still covered and still missing 1000lbs strap -- Missing roof jack for bathroom fan on main level Missing LUS28 at first F02 and missing OSB gusset per engineer letter -- Sliding glass door calls for (3) king studs on each side -- Window at rear of great room calls for (4) king stud and ST18 at pack of (3) middle trimmers -- Window on side of great room calls for (3) kings on each side -- Tie walls together at kitchen pop out balloon framed wall -- Missing roof jack for range vent -- Front window in dining room calls for for (4) king studs and ST18 at pack of (3) trimmers -- Missing (2) 2x6 post and (2) H2.5's on each end of girder B01 -- Missing truss bracing on B02 -- Missing LSTI49 at corners of stair landing -- Missing (5) 2x4 post and (2) TBE4's at mid point bearing for (2) LVL at rear of main level -- Missing (2) 2x4 post under (2) LVL in rear of main level -- Missing (2) 2x4 post under (LVL at front of main level | DAKOTAB | DAKOTAB | | BFR | T | 5411018 |
GOEBEL CONSTRUCTION, INC | BFR | T | 02/07/2017 | PAID (REC#1400880) Inspection stopped at rear room on main level -- Too many items, need to punch house before recalling -- Narrow braced wall covered prior to inspection, can't see nailing pattern -- Missing 1000lb strap from header to trimmer at narrow braced walls -- Missing (3) 2x6 post and (2) H2.5's at each end of D01 in garage -- Fireblock garage door brackets -- Windows at top level bedroom behind garage call for (4) King studs and ST18 at (2) trimmers in middle -- Need engineer letter for windows in rear bedroom on top level not shown on plans -- Strap top plate in rear bedroom on top level left of door -- Truss details and plans show trusses F02 bearing at wall, Need engineer letter for current condition -- Tie balloon framed walls together at corners and tops where top plate don't overlap | DAKOTAB | DAKOTAB | | BFR | T | 5408897 |
GOEBEL CONSTRUCTION, INC | BSP | T | 01/11/2017 | PAID (REC#1394765) PLAN SPLICE FEE: $50 by: JUSTINC for Mechanical: Revised duct design and heat loss calculations | JUSTINC | JUSTINC | | BSP | T | 5386579 |
GOEBEL CONSTRUCTION, INC | BFT | C | 11/28/2016 | open hole, design and letter for footing on file / no drain required | BOBF | BOBF | | BFT | C | 5354323 |
GOEBEL CONSTRUCTION, INC | BFN | C | 11/28/2016 | letter for steel and eufer on file | BOBF | BOBF | | BFN | C | 5354316 |
GOEBEL CONSTRUCTION, INC | BFN | P | 11/03/2016 | AUTHORIZED INSPECTION BY ENGINEER | REBECCA | REBECCA | REBECCA | BFN | P | 5335750 |
GOEBEL CONSTRUCTION, INC | BFT | P | 11/03/2016 | AUTHORIZED INSPECTION BY ENGINEER | REBECCA | REBECCA | REBECCA | BFT | P | 5335751 |
A N' M ELECTRIC | E= | C | 05/04/2017 | | MATTHEW | MATTHEW | | E= | C | 5496071 |
A N' M ELECTRIC | E= | R | 05/03/2017 | install breaker lock for oven ------------- gfi fire place in living room -------------- back fill trench at pole for service lateral ------------ A/C pre wire only / | CRAIG | CRAIG | | E= | R | 5495303 |
A N' M ELECTRIC | ES | C | 05/03/2017 | Residential Underground: 200 - amp 3 Wire service, ok to seal meter / | CRAIG | CRAIG | | ES | C | 5495292 |
A N' M ELECTRIC | EUG | C | 01/17/2017 | 4/0al--------- leave ditch open at pole to check riser | MATTHEW | MATTHEW | | EUG | C | 5390557 |
A N' M ELECTRIC | ES | R | 01/17/2017 | need to land service conductors at meter-------- 200 amp 3/w | MATTHEW | MATTHEW | | ES | R | 5390556 |
A N' M ELECTRIC | ER | C | 01/17/2017 | crawler, no vac, no mcc's, non ir ufer | MATTHEW | MATTHEW | | ER | C | 5390549 |
PRESTIGE MECHANICAL CONTRACTORS,INC | H= | C | 05/10/2017 | | JEFFL | JEFFL | | H= | C | 5501499 |
MICK HEATING & SHEET METAL CO. | H= | P | 05/10/2017 | Unused drain ports on evap coil need plugged. Water heater lacks combustion air. Rest ok. | JEFFL | JEFFL | | H= | P | 5501484 |
PRESTIGE MECHANICAL CONTRACTORS,INC | HI+ | C | 02/21/2017 | 10 lb test ok. Previously inspected by Mark | MARK | MARK | | HI+ | C | 5419251 |
PRESTIGE MECHANICAL CONTRACTORS,INC | HI+ | P | 02/17/2017 | Unable to locate new gas line in patio area. Please be more specific for re inspection. | JEFFL | JEFFL | | HI+ | P | 5418061 |
MICK HEATING & SHEET METAL CO. | HC | C | 02/06/2017 | RELEASE METER | MARK | MARK | | HC | C | 5408087 |
MICK HEATING & SHEET METAL CO. | HRR | C | 02/06/2017 | Heat run to master bath requires 3 screws support and seal joint. Check at final. Check furn condensate at final. Rest ok. Note: Direct vent crawl space location. Equipment matches. a/c rough. | MARK | MARK | | HRR | C | 5407202 |
MICK HEATING & SHEET METAL CO. | HRR | T | 02/02/2017 | PAID (REC#1399863) Still the same, third trip out and not ready. Fees apply. | MARK | MARK | | HRR | T | 5404965 |
MICK HEATING & SHEET METAL CO. | HRR | P | 02/01/2017 | Still need to raise furnace exhaust vent, seal return headers, repair dropped 6" to upper level bedroom, and seal it, seal 6" above mud room and lower make up air to laundry below dropped ceiling. Re inspect all. Note: Fireplace ok. check returns in kitchen at final, leave grills off for inspection. | MARK | MARK | | HRR | P | 5403924 |
PRESTIGE MECHANICAL CONTRACTORS,INC | HI | C | 01/24/2017 | 10 lb test ok. Note: 1 1/4" manifold with 2# to the house regulator at exterior wall. 3/4" CSST to each appliance. Furnace, water heater, fireplace, gas dryer. At final, check gas pipe support in crawl, all. | MARK | MARK | | HI | C | 5396722 |
MICK HEATING & SHEET METAL CO. | HRR | P | 01/23/2017 | Not ready, trip fee waived. Note: Some, not all, Need minimum 1/4" per foot upward slope on furnace exhaust vent, need nail protection for same vent under stairs and back frame these vents in the closet. Dryer vent requires support minimum every 4', support bath fan flex to rafters in attic, Stopped inspection, reinspect all. | MARK | MARK | | HRR | P | 5395362 |
PRESTIGE MECHANICAL CONTRACTORS,INC | HO | C | 01/13/2017 | 10 LB TEST OK . NOTES: FROM METER INSTALLED 200 FT OF 3/4 " POLYETHYLENE PLASTIC TO HOUSE. ANODELESS RISER AT METER AND AT HOUSE, 97 K MAX LOAD. | LIDO | LIDO | | HO | C | 5389439 |
PRESTIGE MECHANICAL CONTRACTORS,INC | P= | C | 05/10/2017 | Certification of potable water to scanning. | CRADE | CRADE | | P= | C | 5501231 |
PRESTIGE MECHANICAL CONTRACTORS,INC | PWO | C | 05/09/2017 | Note:ok.H20 under footer.Need certification of potable water. | CRADE | CRADE | | PWO | C | 5500336 |
PRESTIGE MECHANICAL CONTRACTORS,INC | P= | P | 05/09/2017 | Need certification of potable water.Rest ok. | CRADE | CRADE | | P= | P | 5500335 |
PRESTIGE MECHANICAL CONTRACTORS,INC | PTO+ | C | 02/28/2017 | AAV AT MASTER ON RIGHT ( HERS ) | GABE | GABE | | PTO+ | C | 5427276 |
PRESTIGE MECHANICAL CONTRACTORS,INC | PTO | C | 01/26/2017 | Crawlspace. | TED | TED | | PTO | C | 5399854 |