ALEXANDHER BUILDING CO, INC. | B= | C | 02/06/2017 | All other required Final inspections are complete. (This is a computer generated result) | DANE | DANE | | B= | C | 5407804 |
ALEXANDHER BUILDING CO, INC. | BSP | T | 02/03/2017 | PAID (REC#1399967) PLAN SPLICE FEE: $50 by: TCRIPPEN for Plumbing: plumbing splice 2-3-17 | TCRIPPEN | TCRIPPEN | | BSP | T | 5406467 |
AIRTECH MECHANICAL, INC. | BSP | P | 02/03/2017 | PLAN SPLICE: (No Fee) by: JUSTINC for Mechanical: Revised to change water heater BTU and changed to 80% afue | JUSTINC | JUSTINC | | BSP | P | 5406426 |
ALEXANDHER BUILDING CO, INC. | B= | P | 01/31/2017 | final OK pending other finals. Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2), External Agency Inspection Z= by ZONING is not Completed yet (Contact: 719-385-5982), External Agency Inspection HD= by HEALTHDEPT is not Completed yet, AIR TECH MECHANICAL INC Mechanical Final Inspection is not Completed yet. | DANE | DANE | | B= | P | 5403085 |
EL PASO ELECTRIC, LLC. | BSP | P | 01/25/2017 | PLAN SPLICE: (No Fee) by: BERTHA for Electrical: Revised conductors to reflect AL instead of CU | BERTHA | BERTHA | | BSP | P | 5398874 |
DRUMMOND PLUMBING LLC | BSP | P | 01/25/2017 | PLAN SPLICE: (No Fee) by: TCRIPPEN for Plumbing: plumbing splice 1-25-17 | TCRIPPEN | TCRIPPEN | | BSP | P | 5398848 |
DRUMMOND PLUMBING LLC | BSP | P | 01/25/2017 | PLAN SPLICE: (No Fee) by: JUSTINC for Plumbing: Revised to remove dishwasher hood and fan | JUSTINC | JUSTINC | | BSP | P | 5398764 |
ALEXANDHER BUILDING CO, INC. | BSP | T | 01/25/2017 | PAID (REC#1398773) PLAN SPLICE FEE: $50 by: DANM for Construction: Minor floor plan revisions and addition of patio seating | DANM | DANM | | BSP | T | 5398627 |
ALEXANDHER BUILDING CO, INC. | BFR | P | 12/28/2016 | All combustible materials removed / Still need to splice in all changes from previous inspection / training with Rich B | DANE | DANE | | BFR | P | 5377930 |
ALEXANDHER BUILDING CO, INC. | BFR | P | 12/20/2016 | All light gauge steel framing OK / need to remove all combustible framing at bar seating area / need to splice in changes at cooler and employee restroom and change to grid-x ceiling behind bar / discussed accessible elements with contractor / all pending other roughs / training with Justin L | DANE | DANE | | BFR | P | 5372551 |
EL PASO ELECTRIC, LLC. | E= | C | 01/31/2017 | | BRET | BRET | | E= | C | 5402923 |
EL PASO ELECTRIC, LLC. | ER | P | 01/30/2017 | kitchen ceiling ok, mc hanging out of ceiling and support wire for fan in bath | BRET | BRET | | ER | P | 5401407 |
CONVERGINT TECHNOLOGIES, LLC | E= | C | 01/27/2017 | FIRE ALARM INSPECTION: | BRET | BRET | | E= | C | 5400610 |
CONVERGINT TECHNOLOGIES, LLC | ER | C | 01/27/2017 | FIRE ALARM INSPECTION: | BRET | BRET | | ER | C | 5400602 |
CONVERGINT TECHNOLOGIES, LLC | E= | C | 01/27/2017 | FIRE ALARM INSPECTION: | BRET | BRET | | E= | C | 5400603 |
EL PASO ELECTRIC, LLC. | ES | C | 01/19/2017 | Commercial Service: 200 amp service for unit 148 needs meter set. branch circuits not made will need panel inspection. | BRET | BRET | | ES | C | 5393019 |
EL PASO ELECTRIC, LLC. | ER | P | 12/30/2016 | hard lid ok | BRET | BRET | | ER | P | 5379998 |
EL PASO ELECTRIC, LLC. | ER | P | 12/20/2016 | walls. | BRET | BRET | | ER | P | 5372331 |
EL PASO ELECTRIC, LLC. | ESL | C | 12/01/2016 | | BRET | BRET | | ESL | C | 5357621 |
AIRTECH MECHANICAL, INC. | H= | C | 02/06/2017 | MECHANICAL FINAL OK. TEST AND BALANCE REPORT RECEIVED. | NANCY | NANCY | | H= | C | 5407803 |
AIRTECH MECHANICAL, INC. | H= | P | 02/03/2017 | SEE INSPECTION NOTE DATED 1/26/17 REGARDING 80% WATER HEATER INSTALLED. NEED REVISED/APPROVED PRINTS AND PLUMBING SCHEDULE. ALSO NEED ENGINEER TO PROVIDE COMBUSTION AIR INFORMATION FOR WATER HEATER. STILL NEED TO SEE THAT STAINLESS ON HOOD WALL IS SEALED AT SEAMS. NEED TO SEE T-STATS LABELED. PROVIDE TEST AND BALANCE REPORT. | NANCY | NANCY | | H= | P | 5406769 |
AIRTECH MECHANICAL, INC. | H= | P | 02/01/2017 | PROPERLY INSULATE GREASE DUCT ACCESS DOOR. LABEL T-STATS AND REMOTE INDICATORS. PERMANENTLY LABEL EQUIPMENT ON ROOF WITH SUITE NUMBER. SEAL GAPS BETWEEN SHEETS OF STAINLESS BEHIND AND ABOVE HOOD. PROVIDE TEST AND BALANCE REPORT. | NANCY | NANCY | | H= | P | 5404522 |
DRUMMOND PLUMBING LLC | H= | C | 01/31/2017 | GAS FINAL OK. | NANCY | NANCY | | H= | C | 5402878 |
AIRTECH MECHANICAL, INC. | HD | P | 01/26/2017 | NEED REVISED/APPROVED PRINTS SHOWING 80% WATER HEATER INSTALLED. ENGINEER TO PROVIDE INFORMATION ON COMBUSTION AIR FOR WATER HEATER. I THINK YOU CALLED IN THE WRONG INSPECTION, THERE IS NO FIRE DAMPER ON THIS JOB. WENT AHEAD AND DID ABOVE CEILING INSPECTION. ABOVE CEILING OK, OK TO INSTALL DIFFUSERS WHEN THEY ARRIVE ON SITE. | NANCY | NANCY | | HD | P | 5399920 |
DRUMMOND PLUMBING LLC | HI | C | 01/19/2017 | 10 LB TEST OK ON COOK LINE. | NANCY | NANCY | | HI | C | 5393470 |
AIRTECH MECHANICAL, INC. | HD | P | 01/19/2017 | GREASE DUCT OK, OK TO WRAP. STILL NEED TO SEE FLANGE CONNECTION AT CURB. | NANCY | NANCY | | HD | P | 5393469 |
AIRTECH MECHANICAL, INC. | HD | P | 01/18/2017 | REPAIR HOLES IN GREASE DUCT. | NANCY | NANCY | | HD | P | 5391371 |
DRUMMOND PLUMBING LLC | HI | P | 01/18/2017 | COOK LINE NOT UNDER TEST. INSTALLED AS PER PRINTS. | NANCY | NANCY | | HI | P | 5391370 |
AIRTECH MECHANICAL, INC. | HD | P | 01/17/2017 | REPAIR HOLES IN GREASE DUCT, DO NOT WRAP THIS LAST JOINT. NO ROOF TODAY. | NANCY | NANCY | | HD | P | 5390704 |
DRUMMOND PLUMBING LLC | HC | C | 01/13/2017 | OK TO SET 2 LB METER. | NANCY | NANCY | | HC | C | 5388845 |
DRUMMOND PLUMBING LLC | HI | P | 01/13/2017 | BY FINAL NEED LETTER FROM CSU APPROVING MEDIUM PRESSURE GAS FOR THIS ADDRESS/SUITE. 10 LB TEST OK FOR GAS ON ROOF ONLY. INSTALLED AS PER PRINTS. | NANCY | NANCY | | HI | P | 5388839 |
AIRTECH MECHANICAL, INC. | HD | P | 01/13/2017 | COMPLETE WELD ON VERTICAL DROP. STILL NEED TO SEE CONNECTION BETWEEN GREASE DUCT FLANGE AND CURB. REST OF GREASE DUCT OK. | NANCY | NANCY | | HD | P | 5388833 |
AIRTECH MECHANICAL, INC. | HD | P | 01/12/2017 | GREASE DUCT AS MARKED 1/12/17 OK. OK TO INSTALL BOTH LAYERS OF WRAP ON DROP THROUGH CURB. | NANCY | NANCY | | HD | P | 5387913 |
AIRTECH MECHANICAL, INC. | HD | P | 12/30/2016 | NEED REFRIGERATION CONTRACTOR ATTACHED TO PERMIT. CONTRACTOR INSTALLING WATER HEATER VENT NEEDS TO ADD IT TO THEIR SCOPE OF WORK AND CALL FOR INSPECTION WHEN READY. HOOD WALL OK, OK TO COVER PER MECHANICAL ONLY. RTU'S 8 AND 9 EXPOSED SUPPLY/RETURN DUCTS OK. RTU-10 SUPPLIES AND RETURN ABOVE CEILING OK, INCLUDING ABOVE SUSHI BAR HARD LID. HAVE ACCESS TO MANUAL VOLUME DAMPERS ABOVE SUSHI BAR BY FINAL BATH EXHAUST DUCT THROUGH ROOF ONLY TODAY. NO ROOF TODAY. SEE EQUIPMENT SCHEDULE FOR INTERLOCKS AND CO2 SENSOR. | NANCY | NANCY | | HD | P | 5380426 |
DRUMMOND PLUMBING LLC | P= | C | 02/03/2017 | CORRECTIONS MADE , FILL AND DRAIN INSTALLED | GABE | GABE | | P= | C | 5405863 |
DRUMMOND PLUMBING LLC | P= | P | 01/30/2017 | need to complete fill and drain kit @ roof. rest ok, per plan. NOTE: splice complete for floor sink relocation. | JOHNS | JOHNS | | P= | P | 5401436 |
DRUMMOND PLUMBING LLC | PTO | C | 12/20/2016 | NOTE : DWV AND WATER TO PLAN AND ON TEST | GABE | GABE | | PTO | C | 5372733 |
DRUMMOND PLUMBING LLC | PB | C | 11/30/2016 | NOTE : SANITARY AND GREASE DWV ON TEST , NEED TO SPLICE PLANS TO SHOW RELOCATION OF FLOOR SINK AND TIE IN TO GREASE , ALL UNDER SLAB COPPER OK TO COVER . | GABE | GABE | | PB | C | 5356602 |