HOMES BY MICHAEL HALL, LLC. | B= | C | 04/07/2018 | All other required Final inspections are complete. (This is a computer generated result) | DANE | DANE | | B= | C | 5810819 |
HOMES BY MICHAEL HALL, LLC. | B= | P | 03/15/2018 | items corrected / final OK pending other finals. Additional Inspections Required (computer generated): External Agency Inspection Z= by ZONING is not Completed yet (Contact: 719-385-5982). | DANE | DANE | | B= | P | 5790059 |
HOMES BY MICHAEL HALL, LLC. | BFR | P | 03/15/2018 | engineer letter of compliance for welding and bolting received / frame complete pending other roughs | DANE | DANE | | BFR | P | 5790053 |
HOMES BY MICHAEL HALL, LLC. | BFN | C | 03/15/2018 | open hole received | DANE | DANE | | BFN | C | 5790049 |
HOMES BY MICHAEL HALL, LLC. | B= | P | 03/09/2018 | still need stamped copy of open hole and stamped copy of welding and bolting observations / need to seal penetration at wires for sign over 1327 and need to seal penetrations at all pipes at rear of building to make building weather resistant -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): External Agency Inspection Z= by ZONING is not Completed yet (Contact: 719-385-5982). | DANE | DANE | | B= | P | 5784884 |
HOMES BY MICHAEL HALL, LLC. | BFR | P | 01/30/2018 | UPON FURTHER REVIEW: Demising wall between tenants, is not required to be rated per the occupancy of the occupied space. Each Tenant Finish will be required to provide a code analysis for the demising walls upon issuance of permit. | JEREMYA | JEREMYA | | BFR | P | 5751192 |
HOMES BY MICHAEL HALL, LLC. | BIN | P | 01/22/2018 | Exterior thermal OK at entire building // West demising wall insulation OK // Will need to see insulation in 2nd demising wall once complete as it is a rated assembly with specific insulation requirements | JEREMYA | JEREMYA | | BIN | P | 5744046 |
HOMES BY MICHAEL HALL, LLC. | BFR | P | 01/22/2018 | Balance of exterior wall framing OK // Demising wall framing on core/shell permit. Stamped drawings show this as a UL U419 designed 1-hr wall. Will need to change listing to one that allows the use of American Gyp, or, build wall according to the approved listing with USG product. Will also need penetration details for any penetrating items as well as a head wall detail. | JEREMYA | JEREMYA | | BFR | P | 5744039 |
HOMES BY MICHAEL HALL, LLC. | BFN | C | 07/07/2017 | engineer observation for Eufer received | DANE | DANE | | BFN | C | 5556709 |
HOMES BY MICHAEL HALL, LLC. | BLA | C | 07/05/2017 | stucco lath OK | DANE | DANE | | BLA | C | 5554974 |
JLC ELECTRIC LLC | BSP | T | 06/13/2017 | PAID (REC#1431444) PLAN SPLICE FEE: $50 by: BERTHA for Electrical: Changed service from bussed gutter to depict A.M.P. gear. | BERTHA | BERTHA | | BSP | T | 5533574 |
HOMES BY MICHAEL HALL, LLC. | BFR | P | 05/26/2017 | engineer observation report for welding and bolting received / engineer observations for bond beams received | DANE | DANE | | BFR | P | 5517997 |
HOMES BY MICHAEL HALL, LLC. | BFR | P | 04/21/2017 | exterior light gauge faming at grid lines 1 to 7 and A to B OK pending other roughs / need stamped engineer observations for welding and bolting and bond beams | DANE | DANE | | BFR | P | 5483190 |
HOMES BY MICHAEL HALL, LLC. | BFN | C | 02/03/2017 | Engineers observation Letter on file / Eufer noted | DANE | DANE | | BFN | C | 5405830 |
HOMES BY MICHAEL HALL, LLC. | BFT | C | 02/03/2017 | Engineers observation Letter on file / Soils report on file | DANE | DANE | | BFT | C | 5405826 |
HOMES BY MICHAEL HALL, LLC. | BFN | P | 12/28/2016 | Ok for engineer to inspect / observation letters to follow | JOHN | JOHN | | BFN | P | 5378031 |
HOMES BY MICHAEL HALL, LLC. | BFT | P | 12/28/2016 | Ok for engineer to inspect / observation letters to follow | JOHN | JOHN | | BFT | P | 5378030 |
JLC ELECTRIC LLC | E= | C | 02/16/2018 | | BRET | BRET | | E= | C | 5768062 |
JLC ELECTRIC LLC | ES | P | 06/26/2017 | Pre Release Only1200 amp UG Comm.,New---4 Sets 500 AL.---OK to set House Meter----Need bells on PVC pipes and complete water ground---- | ROB | ROB | | ES | P | 5547233 |
JLC ELECTRIC LLC | ES | R | 06/23/2017 | canceled by contractor, need plans and equipment open for inspection. | BRET | BRET | | ES | R | 5545046 |
JLC ELECTRIC LLC | ER | P | 05/24/2017 | house panel room only ok | CRAIG | CRAIG | | ER | P | 5515399 |
JLC ELECTRIC LLC | ER | P | 05/10/2017 | exterior soffit recessed cans | BRET | BRET | | ER | P | 5501852 |
JLC ELECTRIC LLC | ER | P | 05/02/2017 | recessed cans in north exterior soffit | BRET | BRET | | ER | P | 5493331 |
JLC ELECTRIC LLC | ER | P | 04/25/2017 | store front wall except can recessed cans in soffit | BRET | BRET | | ER | P | 5486233 |
JLC ELECTRIC LLC | EUG | C | 04/25/2017 | s.w pole. | BRET | BRET | | EUG | C | 5486211 |
AIRTECH MECHANICAL, INC. | H= | C | 12/18/2017 | MECHANICAL FINAL OK. NOTE: SMOKE DETECTORS INSTALLED IN ALL UNITS. | NANCY | NANCY | | H= | C | 5716231 |
FRONTIER MECHANICAL SYSTEMS INC | H= | C | 08/25/2017 | GAS FINAL OK. | NANCY | NANCY | | H= | C | 5607358 |
FRONTIER MECHANICAL SYSTEMS INC | HC | C | 08/18/2017 | RELEASE METER | LIDO | LIDO | | HC | C | 5599896 |
FRONTIER MECHANICAL SYSTEMS INC | HI | C | 08/18/2017 | 6 - 10 LB TESTS OK. GAS PIPE SYSTEM IS INSTALLED PER PLAN .Need to see regulators installed and final connection at final , label each meter for the RTU is is serving. | LIDO | LIDO | | HI | C | 5599894 |
FRONTIER MECHANICAL SYSTEMS INC | HI | P | 07/12/2017 | AUTO CALL COMPLETE AT 11:15 - ARRIVED 11:45 - NO ONE ONSITE - NEED ACCESS TO ROOF TO VERIFY PIPING - PRESSURE TESTS ARE COMPLETE | JERRYF | JERRYF | | HI | P | 5561691 |
FRONTIER MECHANICAL SYSTEMS INC | P= | C | 10/30/2017 | Correction made | SHANEN | SHANEN | | P= | C | 5671564 |
FRONTIER MECHANICAL SYSTEMS INC | P= | P | 10/27/2017 | Need trap guard at floor sink, rest OK | SHANEN | SHANEN | | P= | P | 5670097 |
FRONTIER MECHANICAL SYSTEMS INC | PTO | C | 09/01/2017 | CORE SHELL ONLY , ALL TO PLAN . WATER ENTRY OK | GABE | GABE | | PTO | C | 5613960 |
FRONTIER MECHANICAL SYSTEMS INC | PTO | P | 08/25/2017 | building water main and water entry vent , need access to water entry to complete | GABE | GABE | | PTO | P | 5607453 |
FRONTIER MECHANICAL SYSTEMS INC | PTO | P | 06/20/2017 | GREASE TRAP VTR ON TEST | GABE | GABE | | PTO | P | 5541040 |
FRONTIER MECHANICAL SYSTEMS INC | PB | C | 01/31/2017 | ok. | JOHNS | JOHNS | | PB | C | 5402532 |