GE JOHNSON CONSTRUCTION COMPANY, INC. | B= | C | 07/25/2017 | | NATHAN | NATHAN | | B= | C | 5574593 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | B= | P | 07/18/2017 | PHASE 3 AREA 5A okay with all completed final MEP's, marking and above ceiling okay -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): MECH ONE, INC. Mechanical Final Inspection is not Completed yet. | NATHAN | NATHAN | | B= | P | 5567587 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BSP | P | 06/02/2017 | firestopping at door prior to soffit door 5677A with approved mechanical for dampers | NATHAN | NATHAN | | BSP | P | 5523657 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFR | P | 05/11/2017 | with completed required inspections frame okay at east side wall room 5640 area 5A above ceiling inspection needed throughout area 5A. | NATHAN | NATHAN | | BFR | P | 5502827 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | B= | P | 03/22/2017 | With all completed required inspections interior finish phase 5B okay. Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2), BERWICK ELECTRIC CO Electrical Final Inspection is not Completed yet, MECH ONE, INC. Mechanical Final Inspection is not Completed yet, OLSON PLUMBING & HEATING CO Plumbing Final Inspection is not Completed yet. | NATHAN | NATHAN | | B= | P | 5452572 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFR | P | 03/02/2017 | above ceiling penetration inspection all rated walls at area 5B have been completed with all required inspections. | NATHAN | NATHAN | | BFR | P | 5429515 |
OLSON PLUMBING & HEATING COMPANY | BSP | T | 01/17/2017 | PAID (REC#1395560) PLAN SPLICE FEE: $50 by: TCRIPPEN for Plumbing: plumbing splice 1-17-17 | TCRIPPEN | TCRIPPEN | | BSP | T | 5390502 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BSP | P | 01/17/2017 | PLAN SPLICE: (No Fee) by: SHELLEY for Construction: dialysis machine locations clarified | SHELLEY | SHELLEY | | BSP | P | 5390478 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | E= | C | 07/18/2017 | FIRE ALARM INSPECTION: | CRAIGS | CRAIGS | | E= | C | 5567361 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | ER | C | 07/18/2017 | FIRE ALARM INSPECTION: | CRAIGS | CRAIGS | | ER | C | 5567360 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | E= | C | 07/13/2017 | | CRAIGS | CRAIGS | | E= | C | 5562770 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | ER | P | 06/29/2017 | above ceiling-- west --OK | CRAIGS | CRAIGS | | ER | P | 5550530 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | ER | P | 06/02/2017 | 5 th floor head walls OK | CRAIGS | CRAIGS | | ER | P | 5523561 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | ER | P | 05/17/2017 | east three rooms in icu pre rock OK | CRAIGS | CRAIGS | | ER | P | 5508845 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | ER | P | 05/10/2017 | 5 th floor end walls and bathroom walls -- see drawings ---OK | CRAIGS | CRAIGS | | ER | P | 5501422 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | ER | P | 05/03/2017 | FIRE ALARM INSPECTION: fire alarm in ceilings of patient beds 5th floor west | MATTHEW | MATTHEW | | ER | P | 5494392 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | ER | P | 05/03/2017 | 1 outlet and 1 data in wall at head wall locations----- head walls not installed at this time | MATTHEW | MATTHEW | | ER | P | 5494371 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | E= | P | 03/16/2017 | FIRE ALARM INSPECTION: east half 5th floor OK | CRAIGS | CRAIGS | | E= | P | 5442604 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | E= | P | 03/16/2017 | east half of 5th floor ---------OK | CRAIGS | CRAIGS | | E= | P | 5442597 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | ER | P | 03/01/2017 | above ceiling phase one | CRAIGS | CRAIGS | | ER | P | 5427871 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | ER | P | 03/01/2017 | FIRE ALARM INSPECTION: above ceiling phase one | CRAIGS | CRAIGS | | ER | P | 5427865 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | ER | P | 02/08/2017 | see approved drawings high lighted in blue --- can lights and head walls | CRAIGS | CRAIGS | | ER | P | 5409486 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | ER | P | 01/24/2017 | high lighted green -- see drawings | CRAIGS | CRAIGS | | ER | P | 5396943 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | ER | P | 01/12/2017 | phase 5 -- high lighted in purple --- see drawings | CRAIGS | CRAIGS | | ER | P | 5387452 |
MECHONE, INC. | H= | C | 07/25/2017 | TAB REPORT RECEIVED AND CEILING LABELED | JERRYF | JERRYF | | H= | C | 5574554 |
MECHONE, INC. | H= | P | 07/18/2017 | PARTIAL PENDING TAB REPORT AND LABEL F/SD'S AT CEILING GRID | JERRYF | JERRYF | | H= | P | 5568089 |
MECHONE, INC. | HD | P | 06/01/2017 | FIRE DAMPER RETAINAGE AND ACCESS DOORS OK | JERRYF | JERRYF | | HD | P | 5522637 |
MECHONE, INC. | HD | P | 05/24/2017 | F/SD FRAMING ABOVE DOOR OK - AT FUTURE INSPECTION VERIFY STRUCTURAL SUPPORT PER ENGINEER LETTER | JERRYF | JERRYF | | HD | P | 5515451 |
OLSON PLUMBING & HEATING COMPANY | P= | C | 07/14/2017 | ok for rm #'s 5640-5666 and all hallway sinks | JOHNS | JOHNS | | P= | C | 5564336 |
OLSON PLUMBING & HEATING COMPANY | PTO | P | 05/05/2017 | rooms 5640 - 5666 ok. | TAYLOR | TAYLOR | | PTO | P | 5497248 |
OLSON PLUMBING & HEATING COMPANY | P= | P | 03/20/2017 | rooms 5608 - 5638 ok. | TAYLOR | TAYLOR | | P= | P | 5445416 |
OLSON PLUMBING & HEATING COMPANY | P= | L | 03/17/2017 | no call ahead number, no point of contact, unknown area of inspection. | TAYLOR | TAYLOR | | P= | L | 5443945 |
OLSON PLUMBING & HEATING COMPANY | PTO | P | 01/13/2017 | rooms 5608 - 5638 ok, note: need mechanical permit attached. | TAYLOR | TAYLOR | | PTO | P | 5388413 |