ALLIANCE HOMES, LLC | B= | C | 08/28/2017 | Previous items complete / basement being finished under permit K77914 | RICHB | RICHB | | B= | C | 5609001 | ALLIANCE HOMES, LLC | B= | R | 08/25/2017 | House numbers need to be minimum 5" high with 1/2" stroke / verify 12x30 windows at floor level in master bedroom are tempered - could not find etching / complete electrical work in bathroom - (2) open boxes with wiring exposed / need permit pulled for basement finish - framing and rough-ins already ongoing without permit / NOTES - rear deck (no stair) - unfinished basement - AC installed | RICHB | RICHB | | B= | R | 5607620 | ALLIANCE HOMES, LLC | BLA | C | 05/11/2017 | | LINDSEY | LINDSEY | | BLA | C | 5503187 | ALLIANCE HOMES, LLC | BIN | C | 05/10/2017 | | LINDSEY | LINDSEY | | BIN | C | 5501778 | ALLIANCE HOMES, LLC | BIN | R | 05/08/2017 | not ready | LINDSEY | LINDSEY | | BIN | R | 5498957 | ALLIANCE HOMES, LLC | BFR | P | 05/04/2017 | received engineering for repairs / ok to insulate first floor and draft stop basement / Complete Foam and Firestop / | ERICR | ERICR | | BFR | P | 5496145 | ALLIANCE HOMES, LLC | BFR | R | 05/02/2017 | to many items to list | ERICR | ERICR | | BFR | R | 5493677 | ALLIANCE HOMES, LLC | BSP | P | 03/02/2017 | front and rear porches ok // back deck framing ok // narrow wall at garage ok | LINDSEY | LINDSEY | | BSP | P | 5429497 | ALLIANCE HOMES, LLC | BSP | T | 02/03/2017 | PAID (REC#1400027) PLAN SPLICE FEE: $50 by: DANM for Construction: Add deck | DANM | DANM | | BSP | T | 5406709 | ALLIANCE HOMES, LLC | BSP | T | 01/06/2017 | PAID (REC#1393612) PLAN SPLICE FEE: $50 by: DANM for Construction: Revisions to floor and roof framing | DANM | DANM | | BSP | T | 5384202 | ALLIANCE HOMES, LLC | BFD | C | 12/21/2016 | Foundation design on file | LINDSEY | LINDSEY | | BFD | C | 5373798 | ALLIANCE HOMES, LLC | BFD | P | 12/21/2016 | Open Hole | LINDSEY | LINDSEY | | BFD | P | 5373175 | ALLIANCE HOMES, LLC | BFN | C | 12/21/2016 | 3rd Party letter of observation on file | LINDSEY | LINDSEY | | BFN | C | 5373173 | ALLIANCE HOMES, LLC | BFI | P | 12/19/2016 | Still need third party engineer letter of observation on file for footer and foundation | LINDSEY | LINDSEY | | BFI | P | 5371159 | ALLIANCE HOMES, LLC | BFD | P | 12/19/2016 | Still need stamped engineer letter of observation for footer and foundation | LINDSEY | LINDSEY | | BFD | P | 5371158 | ALLIANCE HOMES, LLC | BFN | P | 12/19/2016 | Open hole on file // still need engineers observation letter for footer and foundation | LINDSEY | LINDSEY | | BFN | P | 5371157 | ALLIANCE HOMES, LLC | BFD | P | 12/16/2016 | drain ok // ok to backfill // daylights at both north corners // still need stamped soils report, open hole, foudnation design and 3rd party engineer letter of observation | LINDSEY | LINDSEY | | BFD | P | 5370442 | ALLIANCE HOMES, LLC | BFI | P | 12/16/2016 | need stamped soils report, open hole, foundation design, and 3rd party engineer letter of observation | LINDSEY | LINDSEY | | BFI | P | 5370441 | ALLIANCE HOMES, LLC | BFN | P | 12/16/2016 | need stanped soils report, open hole, foundation design and 3rd party engineer letter of observation | LINDSEY | LINDSEY | | BFN | P | 5370304 | ALLIANCE HOMES, LLC | BFT | C | 12/16/2016 | need stanped soils report, open hole, foundation design and 3rd party engineer letter of observation | LINDSEY | LINDSEY | | BFT | C | 5370298 | ALLIANCE HOMES, LLC | BFT | C | 12/16/2016 | Foundation Insulation ok// still need stanped soils report, open hole, foundation design and 3rd party engineer letter of observation | LINDSEY | LINDSEY | | BFT | C | 5370285 | ALLIANCE HOMES, LLC | BFT | P | 11/30/2016 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFT | P | 5356201 | ALLIANCE HOMES, LLC | BFN | P | 11/30/2016 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFN | P | 5356200 | HOMERUN ELECTRONICS, INC. | E= | C | 08/23/2017 | final for upstairs only, | JOHNN | JOHNN | | E= | C | 5604176 | HOMERUN ELECTRONICS, INC. | E= | P | 08/21/2017 | need floor heat t stat installed and working, | JOHNN | JOHNN | | E= | P | 5601534 | HOMERUN ELECTRONICS, INC. | E= | P | 08/17/2017 | floor heat master bath: need raceway to floor for heated conductors, and box installed----------------------------40 amp a/c,ok | JOHNN | JOHNN | | E= | P | 5598528 | HOMERUN ELECTRONICS, INC. | E= | R | 08/14/2017 | master bath: need gfci for tv outlet,--------------------check a/c cond wiring next time, | JOHNN | JOHNN | | E= | R | 5594734 | HOMERUN ELECTRONICS, INC. | E= | P | 08/10/2017 | still need 5 areas LV/120V outlets with power and on afci,------------------this is first floor only, | JOHNN | JOHNN | | E= | P | 5591559 | HOMERUN ELECTRONICS, INC. | E= | R | 08/03/2017 | outside rear door missing fixture,5 areas with nm cable hanging out,need box or device, butler pantry: nm cable hanging out of wall,put in box or mount fixture,master bath: need outlet within 3' of sink,under cabinet wiremold box missing cover,master closet can not have open fixtures,----------------------50 amp a/c prewire,no cabinet lights installed, this is an inspection for 1st floor only, | JOHNN | JOHNN | | E= | R | 5585066 | HOMERUN ELECTRONICS, INC. | ES | C | 04/27/2017 | Residential Underground: 200-amp 3 Wire service, ok to set meter / | JOHNN | JOHNN | | ES | C | 5488728 | HOMERUN ELECTRONICS, INC. | ER | C | 04/27/2017 | up stairs rough only,ok,down stairs to be on different permit by home owner,-------------------------200 amp,ir ufer,3#6 al,1#10,no mcc,no cv, ---------CHECK WATER BOND ON FINAL,COPPER | JOHNN | JOHNN | | ER | C | 5488719 | BROWN'S HEATING & COOLING, INC | H= | C | 08/15/2017 | Electrical inspector noted to check a/c wire at re-inspect. | MICHAELS | MICHAELS | | H= | C | 5595563 | BROWN'S HEATING & COOLING, INC | H= | P | 08/14/2017 | Pending electrical inspection for a/c. Note: basement on separate permit, full a/c, no mantels. | MICHAELS | MICHAELS | | H= | P | 5594754 | BROWN'S HEATING & COOLING, INC | HC | C | 04/28/2017 | RELEASE METER | DAVIDH | DAVIDH | | HC | C | 5490556 | BROWN'S HEATING & COOLING, INC | HRR | C | 04/28/2017 | UNFINISHED BASEMENT , 6"OSA , | DAVIDH | DAVIDH | | HRR | C | 5490555 | L & L GAS SHOP, LLC. | HI | C | 04/27/2017 | 10 LB TEST OK NOTE 1 1/4" LINE 1 FURN,W/H,RANGE,BBQ, DRYER,FUTURE FIRE PIT AND FUTURE FIREPLACE . 2 FIRE PLACES | DAVIDH | DAVIDH | | HI | C | 5488982 | RIDGEVIEW PLUMBING | P= | C | 08/24/2017 | correction made. | TAYLOR | TAYLOR | | P= | C | 5605852 | RIDGEVIEW PLUMBING | P= | P | 08/18/2017 | waive trip fee, still need access to mixing valve at master tub. | TAYLOR | TAYLOR | | P= | P | 5600244 | RIDGEVIEW PLUMBING | P= | P | 08/14/2017 | flow issues through out, need power supply for recirculating pump and access to mixing valve at master tub, rest ok, RP installed. | TAYLOR | TAYLOR | | P= | P | 5594878 | RIDGEVIEW PLUMBING | PTO | C | 04/27/2017 | ok @ main level, corrections made, bsmnt on seperate permit. | JOHNS | JOHNS | | PTO | C | 5488771 | RIDGEVIEW PLUMBING | PTO | P | 04/26/2017 | LOST TEST AT GUEST BATH DWV , LOW PRESSURE AT WATER , MAIN LEVEL ONLY , BASEMENT UNDER SEPARATE PERMIT , NOTE : RP IN MEC , RECIRC INSTALLED | GABE | GABE | | PTO | P | 5487651 | TEAM PLUMBING, INC. | PB | C | 01/03/2017 | COPPER RUN UNDER FOOTER , BASE ON TEST | GABE | GABE | | PB | C | 5380830 | TEAM PLUMBING, INC. | PB | P | 12/30/2016 | low test dwv | JOEL | JOEL | | PB | P | 5380054 |
|
|