HOMEOWNER | B= | C | 03/07/2018 | update: need to pull additional permit once deck is to be completed | LONNYS | LONNYS | | B= | C | 5782793 |
HOMEOWNER | BSP | P | 03/05/2018 | Remove deck from scope of work | LBENNETT | LBENNETT | | BSP | P | 5780123 |
HOMEOWNER | B= | R | 03/01/2018 | deck still not completed, house is locked so no access to check interior items. Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | BOBF | BOBF | | B= | R | 5778178 |
HOMEOWNER | B= | R | 02/15/2018 | deck not complete / down spouts missing tip outs / need to insulate foundation walls and in basement storage / need to finish upstairs above garage storage room / need to update floor plan for relocated upstairs bathroom / unfinished basement / deck / smokes and COs OK / UPDATE: upon further inspection need to update plans to show above garage storage | LONNYS | LONNYS | | B= | R | 5766951 |
HOMEOWNER | BTR | C | 10/04/2017 | tile roof completed prior to inspection / verified wrap at (3) exposed sections at upper ridge | BRIANB | BRIANB | | BTR | C | 5644616 |
HOMEOWNER | BTR | R | 09/22/2017 | Roof completed before BTR inspection completed | SHAUN | SHAUN | | BTR | R | 5634743 |
HOMEOWNER | BIN | C | 07/19/2017 | | BRIANB | BRIANB | | BIN | C | 5569076 |
HOMEOWNER | BFR | C | 07/19/2017 | roof jacks installed - dry-in complete / note - could not verify wrap at ridges to complete BTR inspection - tile roof completed prior to re-inspection / still need to complete BTR inspection | BRIANB | BRIANB | | BFR | C | 5569065 |
HOMEOWNER | BFR | P | 06/29/2017 | Engineer letter received for as built conditions for windows - door - steel beam supports in basement / Still missing roof jack | JUSTINL | JUSTINL | | BFR | P | 5551652 |
HOMEOWNER | BTR | P | 06/29/2017 | Missing wrap on all ridges | JUSTINL | JUSTINL | | BTR | P | 5550753 |
HOMEOWNER | BLA | C | 06/29/2017 | | JUSTINL | JUSTINL | | BLA | C | 5550744 |
HOMEOWNER | BFR | R | 06/27/2017 | Still Need engineer letter for missing trimmer both sides at each windows and door in basement / Still Need engineer letter for missing 2X4 at beam pockets - plans call for 4 2X4 not 3 2X6 / Still missing roof jacks / NOTE: roof has not received mid roof inspection for tile - most of roof has been tiled | JUSTINL | JUSTINL | | BFR | R | 5547989 |
HOMEOWNER | BIN | R | 06/27/2017 | No insulation installed / Still need to complete frame/trip fee waived by Bert W after speaking with homeowner one time only | JUSTINL | JUSTINL | | BIN | R | 5547975 |
HOMEOWNER | BSP | P | 05/26/2017 | Engineer letter received ready to be scanned for T01 truss change to TBE4 clips / engineer letter received ready to be scanned for GO3 Steel column replacement and GO4 THGQ hanger change | JUSTINL | JUSTINL | | BSP | P | 5518668 |
HOMEOWNER | BFR | P | 05/26/2017 | Need engineer letter for missing trimmer both sides at each windows and door in basement / Need engineer letter for missing 2X4 at beam pockets - plans call for 4 2X4 not 3 2X6 / Complete Foam and Firestop / Missing roof jacks | JUSTINL | JUSTINL | | BFR | P | 5518662 |
HOMEOWNER | BSP | T | 04/24/2017 | PAID (REC#1419534) PLAN SPLICE FEE: $50 by: MICHAELA for Construction: New structural pages | MICHAELA | MICHAELA | | BSP | T | 5485822 |
HOMEOWNER | BSP | P | 04/04/2017 | front porch corrections okay / rear deck frame, posts and lid okay | BRIANB | BRIANB | | BSP | P | 5464295 |
HOMEOWNER | BSP | R | 03/06/2017 | front porch inspection / missing HTS20 and bearing block at T04G truss / missing MTS12 at T04E truss / missing ST18 at both front porch posts | BRIANB | BRIANB | | BSP | R | 5432346 |
HOMEOWNER | BIN | P | 03/05/2017 | Qualified third party energy inspection documentation must be presented at time of final building (B=) inspection | INTERNET | INTERNET | | BIN | P | 5431695 |
HOMEOWNER | BFN | C | 03/01/2017 | rear deck piers okay / foundation observation / foundation design / eufer documented / soils letter / 5000 psf / habitable drain / all paper work on file | BRIANB | BRIANB | | BFN | C | 5428660 |
HOMEOWNER | BFT | C | 12/20/2016 | foundation design on file | BRIANB | BRIANB | | BFT | C | 5372130 |
HOMEOWNER | BFD | C | 12/20/2016 | | BOBF | BOBF | | BFD | C | 5372016 |
HOMEOWNER | BFT | C | 12/20/2016 | letter for steel and eufer on file | BOBF | BOBF | | BFT | C | 5372015 |
HOMEOWNER | BFT | P | 12/20/2016 | open hole, soils and letter for footing on file, still need foundation design | BOBF | BOBF | | BFT | P | 5372012 |
HOMEOWNER | BFI | C | 12/19/2016 | 2" R-10 Rigid | BOBF | BOBF | | BFI | C | 5371835 |
HOMEOWNER | BFD | R | 12/19/2016 | need open hole to verify drain requirements / current drain installed is exterior/usable / need all paperwork for footing and foundation | BOBF | BOBF | | BFD | R | 5371825 |
DUKES ELECTRIC, INC | E= | C | 12/28/2017 | | CRAIG | CRAIG | | E= | C | 5724406 |
DUKES ELECTRIC, INC | E= | L | 12/22/2017 | Gate is locked, no lock code given. | JOSEPH | JOSEPH | | E= | L | 5721270 |
DUKES ELECTRIC, INC | E= | R | 12/21/2017 | Bury UF cables to septic. -------- One of the AFCI breakers in the garage will not work when tested.------------ Notes: AC is pre roughed | JOSEPH | JOSEPH | | E= | R | 5720320 |
DUKES ELECTRIC, INC | ES | C | 05/02/2017 | Residential Underground: 200 - amp 3 Wire service, ok to seal meter / | CRAIG | CRAIG | | ES | C | 5493913 |
DUKES ELECTRIC, INC | ER | C | 05/02/2017 | no mcc 2 - 10/2 10/3 2 - 6/3 cu 2 - 4/w #2 al to both sub panels Cent Vac installed / Non Irreversible UFER connection / unfinished Basement / | CRAIG | CRAIG | | ER | C | 5493912 |
DUKES ELECTRIC, INC | EUG | C | 04/11/2017 | 4/0al service lateral from ped to house | MATTHEW | MATTHEW | | EUG | C | 5471472 |
MILLER HEATING & AIR CONDITIONING, INC. | H= | C | 10/23/2017 | corrections made. note: unfinished basement,10 inch outside air to mechanical room with damper, indirect vent furnace, a/c rough and line set, mantel ok. | PAULO | PAULO | | H= | C | 5664143 |
MILLER HEATING & AIR CONDITIONING, INC. | H= | P | 10/18/2017 | need the following-- cap and collar on water heater b vent. need to properly seal r/a panning in upper level bath(tape coming loose) , change of equipment letter for coil rest ok. note: unfinished basement,10 inch outside air to r/a , indirect vent furnace, a/c rough in line set, mantel ok. ADDED NOTES: 10-20-17.... 1200 CFM RANGE HOOD WILL NEED MAKE UP AIR DIRECTLY FROM OUTSIDE WITH DAMPER. | PAULO | PAULO | | H= | P | 5659079 |
MILLER HEATING & AIR CONDITIONING, INC. | HC | C | 05/24/2017 | RELEASE METER | JERRYF | JERRYF | | HC | C | 5516111 |
MILLER HEATING & AIR CONDITIONING, INC. | HRR | C | 05/24/2017 | CORRECTION MADE | JERRYF | JERRYF | | HRR | C | 5516100 |
MILLER HEATING & AIR CONDITIONING, INC. | HRR | P | 05/23/2017 | B vent still lacks proper clearance to roofing material at roof deck. Note: Change letter received for a/c coil. Return at tub is ok, mason board will complete. | MARK | MARK | | HRR | P | 5515033 |
MILLER HEATING & AIR CONDITIONING, INC. | HRR | P | 05/19/2017 | need the following-- clearance to combustibles from b-vent at roof deck, completely seal R.A. behind tub on upper level, a/c model # does not match what is listed on plans. rest ok. WHAT ARE THE CFM'S OF RANGE HOOD? note: unfinished basement, outside air to mechanical room, indirect vent furnace, a/c rough and line set, duct design. | PAULO | PAULO | | HRR | P | 5511613 |
MILLER HEATING & AIR CONDITIONING, INC. | HRR | R | 05/18/2017 | no access to home (locked), no inspection. | PAULO | PAULO | | HRR | R | 5510520 |
O.M.A.G.M., INC. | HI | C | 05/04/2017 | 10# test ok. note: 1 1/4" main at 80' to furnace, 2- water heaters and range. | PAULO | PAULO | | HI | C | 5495955 |
TEAM PLUMBING, INC. | P= | C | 01/10/2018 | corrections made, potable water certification to scanning | JOSEPHD | JOSEPHD | | P= | C | 5734104 |
TEAM PLUMBING, INC. | P= | P | 12/28/2017 | ejector pit lid is more than 2" below floor level (call in morning 719-492-6383) not all plugs are in place on lid, powder room lav drain back graded, need potable water certification, rest ok note: unfinished basement, bathroom upstairs rough in only | JOSEPHD | JOSEPHD | | P= | P | 5724055 |
TEAM PLUMBING, INC. | PTO | C | 04/17/2017 | Note:unfinished basement,mixing valve at water heater,1/2 bath lav aav,vtr,Need certification of potable water by final. | CRADE | CRADE | | PTO | C | 5477803 |
HOMEOWNER | PWO | C | 03/03/2017 | need certificate of potable water by final | TED | TED | | PWO | C | 5431447 |
TEAM PLUMBING, INC. | PB | C | 01/03/2017 | basement drains to sewage ejector, water run under footer | TED | TED | | PB | C | 5381351 |
HOMEOWNER | XBS | T | 02/27/2018 | PAID (REC#1484325) PLAN SPLICE FEE: $50 by: DANM for Construction: Reconfigure bath and hall way on upper level and add unfinished storage in attic trusses | DANM | DANM | | XBS | T | 5775368 |