INTEGRITY POOL BUILDERS, LLC | B= | C | 10/22/2018 | all corrections made and installed | NATHAN | NATHAN | | B= | C | 6001961 |
INTEGRITY POOL BUILDERS, LLC | B= | R | 07/11/2018 | Need 12' reaching pole on site / Need minimum 15" diameter life ring with 3/16 inch rope lengh of pool on site / Need sign with phone number to local fire/police in case of emergency / Need to install self closing/latching gates throughout / Need latching device to be installed at 4' above bottom of gate or door / Reviewed with contractor / Eng observation on file for pool rebar. Additional Inspections Required (computer generated): External Agency Inspection Z= by MSZONING is not Completed yet (Contact: wburkholder@comsgov.com). UPON FURTHER REVIEW NEED TO ATTACH PLUMBING PERMIT 7/12/18 | NICK | NICK | | B= | R | 5899228 |
INTEGRITY POOL BUILDERS, LLC | BFT | C | 06/12/2018 | Letter to re-certify open hole observation by RMG in 2012 on file | JEREMYA | JEREMYA | | BFT | C | 5871846 |
INTEGRITY POOL BUILDERS, LLC | BFT | P | 05/24/2018 | rebar observation on file pending /soils verification of 1500psf per page 8 of 9 on approved plans | BERTW | BERTW | | BFT | P | 5855565 |
INTEGRITY POOL BUILDERS, LLC | BE | L | 05/22/2018 | Renewed for Full Fee at 5/22/2018 3:07:43 PM (Receipt#1502062) | RITA | RITA | | BE | L | 5852668 |
INTEGRITY POOL BUILDERS, LLC | BE | L | 11/17/2017 | Renewed at 11/17/2017 10:18:10 AM | SABRINA | SABRINA | | BE | L | 5688584 |
ROCKY MOUNTAIN ELECTRICAL SERVICES INC | E= | C | 06/08/2018 | | JOHNN | JOHNN | | E= | C | 5869618 |
ROCKY MOUNTAIN ELECTRICAL SERVICES INC | E= | R | 05/31/2018 | correction not made: bond lift next to pool. | JOHNN | JOHNN | | E= | R | 5860814 |
ROCKY MOUNTAIN ELECTRICAL SERVICES INC | E= | P | 05/24/2018 | need deck box, bond lift next to pool,---builder needs obtain mech,plumbing permits. | JOHNN | JOHNN | | E= | P | 5855624 |
ROCKY MOUNTAIN ELECTRICAL SERVICES INC | E= | R | 11/27/2017 | need POC on site to unlock and open everything up, could not open pvc j box, open splice on cord needs replacing, bond wire in wet niche shell has outer insulation coming off, needs to be replaced, motor bond: loose or need lug, label main panel with # to correspond with cb, can not approve final until pool has water in it,can not test pumps, need grd lug on each motor for #8cu, | JOHNN | JOHNN | | E= | R | 5695188 |
ROCKY MOUNTAIN ELECTRICAL SERVICES INC | ER | P | 06/14/2017 | WET NITCH BONDING OK--- | BRIAN | BRIAN | | ER | P | 5535291 |
ROCKY MOUNTAIN ELECTRICAL SERVICES INC | EUG | P | 05/23/2017 | deck bonding ok | JOHNN | JOHNN | | EUG | P | 5514485 |
ROCKY MOUNTAIN ELECTRICAL SERVICES INC | ER | P | 03/20/2017 | 4 ladder cups,bonding ok | JOHNN | JOHNN | | ER | P | 5445806 |
ROCKY MOUNTAIN ELECTRICAL SERVICES INC | ER | P | 12/28/2016 | pool shell bonding,ok,pvc /trench to equipment ok,wet niche outer shell bonding, ok | JOHNN | JOHNN | | ER | P | 5378468 |
ROCKY MOUNTAIN ELECTRICAL SERVICES INC | EUG | P | 12/16/2016 | from building panel to rack | JOHNN | JOHNN | | EUG | P | 5370476 |
INTEGRITY POOL BUILDERS, LLC | FP= | C | 05/24/2018 | | KEITH | KEITH | BDA | FP= | C | 5855574 |
INTEGRITY POOL BUILDERS, LLC | FP= | R | 12/13/2016 | Entered at Permit Issuance to ensure Floodplain inspections get completed. | JANE | JANE | | FP= | R | 5366335 |
AFFORDABLE PLUMBING & HEAT,INC | H= | C | 06/13/2018 | 10 LB TEST OK | DAVIDH | DAVIDH | | H= | C | 5873224 |
AFFORDABLE PLUMBING & HEAT,INC | H= | T | 06/07/2018 | PAID (REC#1506858): ALL SUBS SHOULD HAVE BEEN ATTACHED TO POOL CONTRACTOR AS PREVIOUSLY STATED IT IS NOT YET BEEN DONE NOT READY . GAS LINE WAS NEVER LOOKED AT NEW LINE AND RISERS INSTALLED NEED POT HOLED AND PRESSURE TEST ALL NEW LINE LINE | DAVIDH | DAVIDH | | H= | T | 5868953 |