HAMMERS CONSTRUCTION, INC | B= | C | 02/10/2017 | All other required Final inspections are complete. (This is a computer generated result) | NATHAN | NATHAN | | B= | C | 5412994 |
HAMMERS CONSTRUCTION, INC | B= | P | 02/09/2017 | . Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet, MARTINSON MECHANICAL, LLC Plumbing Final Inspection is not Completed yet, PEAK HEATING & AIR COND, INC. Mechanical Final Inspection is not Completed yet. | NATHAN | NATHAN | | B= | P | 5411556 |
PEAK HEATING & AIR CONDITIONING, INC. | BSP | T | 02/09/2017 | PAID (REC#1401257) PLAN SPLICE FEE: $50 by: JUSTINC for Mechanical: Revised to remove co2 sensor and adjust O.S.A | JUSTINC | JUSTINC | | BSP | T | 5410660 |
HAMMERS CONSTRUCTION, INC | BFR | P | 01/13/2017 | With all completed MEP's frame okay/ accessible elements are in place / | NATHAN | NATHAN | | BFR | P | 5388926 |
ELECTRIC SERVICE OF COLORADO, LLC | E= | C | 02/08/2017 | | BRIAN | BRIAN | | E= | C | 5410214 |
ELECTRIC SERVICE OF COLORADO, LLC | ER | C | 02/01/2017 | CEILING--OK | BRIAN | BRIAN | | ER | C | 5404478 |
ELECTRIC SERVICE OF COLORADO, LLC | ER | L | 01/31/2017 | doors locked at 10:29 | TOMC | TOMC | | ER | L | 5402526 |
ELECTRIC SERVICE OF COLORADO, LLC | ER | P | 01/12/2017 | WALLS --OK | BRIAN | BRIAN | | ER | P | 5387932 |
PEAK HEATING & AIR CONDITIONING, INC. | H= | C | 02/10/2017 | TAB REPORT RECEIVED | JERRYF | JERRYF | | H= | C | 5411794 |
MARTINSON CONSTRUCTION, LLC | H= | C | 02/09/2017 | CORRECTIONS MADE | JERRYF | JERRYF | | H= | C | 5410611 |
PEAK HEATING & AIR CONDITIONING, INC. | HD | C | 02/08/2017 | DRYER VENT SLEEVE OK - STILL NEED TAB REPORT | JERRYF | JERRYF | | HD | C | 5409886 |
MARTINSON CONSTRUCTION, LLC | H= | P | 02/08/2017 | COULD NOT LOCATE GAS SHUT OFF FOR WATER HEATER IF ABOVE CEILING NEED MARKED BELOW CEILING AND ABOVE CEILING ATTACH PICTURES TO NEXT INSPECTION REQUEST - REST OK | JERRYF | JERRYF | | H= | P | 5409880 |
PEAK HEATING & AIR CONDITIONING, INC. | H= | P | 02/07/2017 | NEED CONVERSATION WITH PREVIOUS INSPECTOR.. IF OK WILL CLOSE PERMIT ON 2-8-17 | JON | JON | | H= | P | 5409119 |
MARTINSON CONSTRUCTION, LLC | HC | C | 02/03/2017 | RELEASE METER | JERRYF | JERRYF | | HC | C | 5406658 |
MARTINSON CONSTRUCTION, LLC | HI | C | 02/03/2017 | AT FINAL VERIFY FINAL CONNECTION AT WATER HEATER - PRESSURE TEST OK - PIPING PER PLAN | JERRYF | JERRYF | | HI | C | 5406657 |
MARTINSON CONSTRUCTION, LLC | HV | C | 02/03/2017 | NEED ROOF INSPECTION AT FINAL TO VERIFY FLUE TERMINATION | JERRYF | JERRYF | | HV | C | 5406656 |
PEAK HEATING & AIR CONDITIONING, INC. | H16 | C | 02/03/2017 | NEED DUCT INSPECTION CALLED ASAP TILE IS ALREADY INSTALLED!!!!!!!! - NEED DRYER VENT ISOLATED IN RA PLENUM | JERRYF | JERRYF | | H16 | C | 5406655 |
MARTINSON MECHANICAL, INC | P= | C | 02/10/2017 | revised plans ok. | JOHNS | JOHNS | | P= | C | 5411771 |
MARTINSON MECHANICAL, INC | P= | P | 02/09/2017 | still waiting on spliced plans as previously noted, rest ok. NOTE: contractor went today to have plans spliced. | JOHNS | JOHNS | | P= | P | 5411184 |
MARTINSON MECHANICAL, INC | P= | P | 02/08/2017 | still need to revise plans to show all 3/4 DHW and DCW, need vaccuum breaker @ water heater per plan specs, leak @ cold ball valve @ water heater, rest ok. NOTE: AT TIME OF NEXT INSPECTION PLEASE HAVE PLUMBING POINT OF CONTACT ON SITE. | JOHNS | JOHNS | | P= | P | 5409664 |
MARTINSON MECHANICAL, INC | PTO | C | 01/11/2017 | check water, H2O tie in, vent termination, and revise plans plans to show all 3/4 DHW and 3/4 DCW by final, aav's at hair sinks, note: need mechanical and electrical permits. | TAYLOR | TAYLOR | | PTO | C | 5387252 |
MARTINSON MECHANICAL, INC | PB | C | 12/19/2016 | revise plans to show all 3/4 inch DHW by final. | TAYLOR | TAYLOR | | PB | C | 5371632 |