MOELLER HOMES LLC | B= | C | 06/13/2017 | | BOBF | BOBF | | B= | C | 5534519 |
MOELLER HOMES LLC | BFD | C | 06/13/2017 | Engineer letter received for Drain | JUSTINL | JUSTINL | | BFD | C | 5533176 |
MOELLER HOMES LLC | B= | R | 06/09/2017 | Need guard at front porch where fall is greater than 30" within 36" of walking surface / Seal all openings along perimeter of garage ceiling / Still need engineer observation for drain. Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | JUSTINL | JUSTINL | | B= | R | 5531169 |
MOELLER HOMES LLC | BIN | C | 04/10/2017 | | BOBF | BOBF | | BIN | C | 5469387 |
MOELLER HOMES LLC | BFR | C | 04/06/2017 | | BOBF | BOBF | | BFR | C | 5467162 |
MOELLER HOMES LLC | BIN | P | 04/06/2017 | need to insulate chases below ducts in garage, missing air barrier behind tub | BOBF | BOBF | | BIN | P | 5467159 |
MOELLER HOMES LLC | BFR | R | 04/03/2017 | missing pipe jack at B vent / FHA straps at top plates of bearing wall at supply and return air / letter for relocating post on T wall on file | BOBF | BOBF | | BFR | R | 5463935 |
MOELLER HOMES LLC | BSP | R | 03/27/2017 | no approved plans on site or in PPRBD system / per previous inspection need eng letter for damaged t wall, approved plans need to be returned to PPRBD to get scanned into system | BOBF | BOBF | | BSP | R | 5456970 |
MOELLER HOMES LLC | BSP | P | 03/07/2017 | Need engineer letter for damaged T wall at bearing -- Front porch lid OK | DAKOTAB | DAKOTAB | | BSP | P | 5434046 |
MOELLER HOMES LLC | BFD | P | 03/07/2017 | Need engineer letter for perimeter drain | DAKOTAB | DAKOTAB | | BFD | P | 5434045 |
MOELLER HOMES LLC | BFN | C | 03/07/2017 | Engineer letter for foundation received -- Eufer noted -- Foundation design received (Bearing capacity verified) | DAKOTAB | DAKOTAB | | BFN | C | 5434044 |
MOELLER HOMES LLC | BFT | C | 03/07/2017 | Engineer letter for footing received -- Open hole and soils received -- 3000 PSF - Drain usable - 5% | DAKOTAB | DAKOTAB | | BFT | C | 5434030 |
MOELLER HOMES LLC | BFT | P | 12/28/2016 | AUTHORIZED INSPECTION BY ENGINEER | REBECCA | REBECCA | REBECCA | BFT | P | 5377570 |
MOELLER HOMES LLC | BFN | P | 12/28/2016 | AUTHORIZED INSPECTION BY ENGINEER | REBECCA | REBECCA | REBECCA | BFN | P | 5377569 |
FIRST RATE ELECTRICAL SERVICES, INC. | E= | C | 06/06/2017 | A/C pre wire only / | CRAIG | CRAIG | | E= | C | 5527208 |
FIRST RATE ELECTRICAL SERVICES, INC. | ES | C | 03/31/2017 | Residential Underground: 200 - amp 3 Wire service, ok to seal meter / | CRAIG | CRAIG | | ES | C | 5462073 |
FIRST RATE ELECTRICAL SERVICES, INC. | ER | C | 03/31/2017 | no mc 2 - 10//3 6/3 al No Cent Vac / Irreversible UFER connection / | CRAIG | CRAIG | | ER | C | 5462057 |
FIRST RATE ELECTRICAL SERVICES, INC. | EUG | P | 02/08/2017 | 4/0-4/0-2/0 install caution tape in trench | BRET | BRET | | EUG | P | 5410256 |
TRUE NORTH MECHANICAL & DESIGN | H= | C | 06/07/2017 | NOTES: 6" horizontal osa to mech room. makeup air grilles to utility room. | ACE | ACE | | H= | C | 5528841 |
TRUE NORTH MECHANICAL & DESIGN | H= | P | 06/06/2017 | Need combustion air for mechanical room (water heater), Need makeup air for laundry room. NOTES: AC coil and line set (no condenser). Performance test received. | ACE | ACE | | H= | P | 5526750 |
TRUE NORTH MECHANICAL & DESIGN | HC | C | 03/31/2017 | RELEASE METER | JEFFL | JEFFL | | HC | C | 5461127 |
TRUE NORTH MECHANICAL & DESIGN | HRR | C | 03/31/2017 | Framing complete. Changed to performance test. | JEFFL | JEFFL | | HRR | C | 5461125 |
WHITE BROS CUSTOM PLUMBING & HEATING | HI | C | 03/29/2017 | 10# test ok. Notes-- 1 1/4'' main.. 1 furnace.. 1 wh.. 1 range.. | JEFFL | JEFFL | | HI | C | 5459565 |
TRUE NORTH MECHANICAL & DESIGN | HRR | P | 03/27/2017 | Mechanical notes stipulate all metal duct work. Several flex runs have been installed. Framing not complete around b vent on upper level. Insulation shield required around b vent in attic. Re inspect all. | JEFFL | JEFFL | | HRR | P | 5457103 |
WHITE BROS CUSTOM PLUMBING & HEATING | P= | C | 06/09/2017 | Certificate of potable to scanning. | CRADE | CRADE | | P= | C | 5530350 |
WHITE BROS CUSTOM PLUMBING & HEATING | P= | P | 06/06/2017 | Need certificate of potable water.Rest ok. | CRADE | CRADE | | P= | P | 5527408 |
HOMEOWNER | PWO | C | 05/02/2017 | ok,H20 under footer.Need certificate of potable water by final. | CRADE | CRADE | | PWO | C | 5493485 |
WHITE BROS CUSTOM PLUMBING & HEATING | PTO | C | 03/03/2017 | aav washer box and kitchen | TED | TED | | PTO | C | 5431494 |
WHITE BROS CUSTOM PLUMBING & HEATING | PB | C | 01/19/2017 | water line under footer but no outside under ground line to well head | TED | TED | | PB | C | 5393273 |