HOMEOWNER | B= | C | 12/05/2017 | upper level walk out deck / no stairs | LONNYS | LONNYS | | B= | C | 5702515 |
HOMEOWNER | BIN | C | 06/30/2017 | | DAKOTAB | DAKOTAB | | BIN | C | 5552366 |
HOMEOWNER | BFR | C | 06/30/2017 | Item corrected | DAKOTAB | DAKOTAB | | BFR | C | 5552360 |
HOMEOWNER | BFR | P | 06/28/2017 | Still need to complete foam/firestop where electrical wires and plumbing penetrate floor on upper level / All other corrections made / OK to insulate | JUSTINL | JUSTINL | | BFR | P | 5549155 |
HOMEOWNER | BSP | P | 06/19/2017 | Engineer letter received for Truss repair - Repair completed per detail / Engineer letter received for changes to framing details | JUSTINL | JUSTINL | | BSP | P | 5540189 |
HOMEOWNER | BFR | P | 06/19/2017 | HUS28s needed at E2 trusses - HUS26 used / Missing VTCR truss clips every 48" OC on V trusses / Secure steel column in garage to beam at garage door / Complete foam and firestop / Block garage door brackets | JUSTINL | JUSTINL | | BFR | P | 5540188 |
HOMEOWNER | BFT | C | 06/19/2017 | Engineers observation Letter received for interior pads and piers / No drain required | JUSTINL | JUSTINL | | BFT | C | 5540187 |
HOMEOWNER | BFN | C | 06/19/2017 | Engineers observation on file for foundation - Existing foundation - 2800 PSF / Foundation design received - Bearing pressure 1500 PSF | JUSTINL | JUSTINL | | BFN | C | 5540186 |
HOMEOWNER | BSP | P | 03/03/2017 | Need engineer letter for rear narrow braced wall, plans call for header to be continuous -- Need engineer letter for missing ledger for rear porch trusses -- Front porch post and lid OK -- Engineer letter for porch piers and pads received | DAKOTAB | DAKOTAB | | BSP | P | 5431493 |
HOMERUN ELECTRONICS, INC. | EP | C | 12/01/2017 | 200 amp 4/w to other sub panel ok | CRAIG | CRAIG | | EP | C | 5700499 |
HOMERUN ELECTRONICS, INC. | E= | C | 12/01/2017 | | CRAIG | CRAIG | | E= | C | 5700498 |
HOMERUN ELECTRONICS, INC. | ER | C | 05/18/2017 | vac wired check panel at final | BRET | BRET | | ER | C | 5510657 |
WESTERN FIREPLACE SUPPLY, INC. | H= | C | 12/04/2017 | Missing gas shut off, it is requires within 6' of the appliance. Rest ok. | MARK | MARK | | H= | C | 5702023 |
BROWN'S HEATING & COOLING, INC | H= | C | 11/21/2017 | MECHANICAL FINAL OK. | NANCY | NANCY | | H= | C | 5691791 |
BROWN'S HEATING & COOLING, INC | H= | P | 11/16/2017 | INSTALL MINIMUM OF 14 X 10 HIGH/LOW COMBUSTION AIR GRILLS FOR WATER HEATER/LAUNDRY ROOM. NEED 1 INCH CLEARANCE FROM B-VENT TO SHEET ROCK. NOTE: SELF CLOSING, GASKETED DOOR FOR FURNACE MECHANICAL ROOM. OUTSIDE AIR X 2. DIRECT VENT FURNACE X 2. UNIT HEATER INSTALLED UNDER PERMIT J95321 (ORIGINAL GARAGE PERMIT). NO GAS LINE FOR FIREPIT, STUB IS FOR BBQ ONLY. | NANCY | NANCY | | H= | P | 5687414 |
L & L GAS SHOP, LLC. | H= | C | 11/01/2017 | | BENH | BENH | | H= | C | 5673579 |
BROWN'S HEATING & COOLING, INC | HC | C | 05/26/2017 | RELEASE METER | JEFFL | JEFFL | | HC | C | 5518377 |
BROWN'S HEATING & COOLING, INC | HRR | C | 05/26/2017 | Correction made. | JEFFL | JEFFL | | HRR | C | 5518365 |
L & L GAS SHOP, LLC. | HI | C | 05/17/2017 | 10# test ok, 1 1/4" main, 2x furn, 1 w/h, 1 fp, 1 bbq, 1 firepit. 1 hanging garage heater. (Black Hills Utilities approved 2# pressure. | ACE | ACE | | HI | C | 5509473 |
BROWN'S HEATING & COOLING, INC | HRR | P | 05/17/2017 | Need to drop vent down through soffit in downstairs bathroom, send pic of cerrection to ace@pprbd.org, NOTES: 2x direct vent furnaces in garage, no AC, duct design ok, 2x osa to return for both units. | ACE | ACE | | HRR | P | 5509464 |
WESTERN FIREPLACE SUPPLY, INC. | HV | C | 03/14/2017 | Fireplace is upstairs. | ACE | ACE | | HV | C | 5441030 |
TEAM PLUMBING, INC. | P= | C | 11/21/2017 | Corrections made
| SHANEN | SHANEN | | P= | C | 5692139 |
TEAM PLUMBING, INC. | P= | P | 11/20/2017 | Need hammer arrestors for dishwashers, rest OK | SHANEN | SHANEN | | P= | P | 5690884 |
TEAM PLUMBING, INC. | PTO | C | 05/08/2017 | Corrections made. | CRADE | CRADE | | PTO | C | 5499098 |
TEAM PLUMBING, INC. | PTO | P | 05/05/2017 | Dwv gauge lost pressure.Rest ok.Note:garage sinks future,garage bath lav aav,upstairs bar sink aav,irrigation stub,vtr. | CRADE | CRADE | | PTO | P | 5497442 |
TEAM PLUMBING, INC. | PB | C | 01/17/2017 | DWV ON TEST , WILL NEED BACK FLOW AT WATER AT FINAL | GABE | GABE | | PB | C | 5390632 |
TEAM PLUMBING, INC. | PWO | C | 01/17/2017 | WATER SLEEVED DEPTH OK , NEED BACK FLOW AT ADDITION AT FINAL | GABE | GABE | | PWO | C | 5390624 |