SC SCOTT CONSTRUCTION CONSULTING, L.L.C. | B= | C | 09/18/2017 | Full finished basement -- Side deck, no stairs | DAKOTAB | DAKOTAB | | B= | C | 5628592 |
SC SCOTT CONSTRUCTION CONSULTING, L.L.C. | BIN | C | 06/05/2017 | | DAKOTAB | DAKOTAB | | BIN | C | 5525383 |
SC SCOTT CONSTRUCTION CONSULTING, L.L.C. | BFR | C | 06/05/2017 | Items corrected -- Engineer letter for gussets on PB01 trusses received | DAKOTAB | DAKOTAB | | BFR | C | 5525377 |
SC SCOTT CONSTRUCTION CONSULTING, L.L.C. | BSP | P | 05/31/2017 | Letter received ready to be scanned for change to window framing in basement and Floor framing change in basement for duct work | JUSTINL | JUSTINL | | BSP | P | 5521206 |
SC SCOTT CONSTRUCTION CONSULTING, L.L.C. | BFR | P | 05/31/2017 | Missing ST18 strap at service door rear of garage / Missing MTS12s on A6-A11 trusses / Missing 1 King stud at right side of master window / missing LTP4s at all PB01 trusses | JUSTINL | JUSTINL | | BFR | P | 5521200 |
SC SCOTT CONSTRUCTION CONSULTING, L.L.C. | BSP | P | 05/09/2017 | Framing and insulation at 2 cantilever OK -- Insulation at front porch lid OK | DAKOTAB | DAKOTAB | | BSP | P | 5500448 |
SC SCOTT CONSTRUCTION CONSULTING, L.L.C. | BSP | T | 04/13/2017 | PAID (REC#1416987) PLAN SPLICE FEE: $50 by: JUSTINC for Mechanical: Revised duct design and associated heat calcs | JUSTINC | JUSTINC | | BSP | T | 5474336 |
SC SCOTT CONSTRUCTION CONSULTING, L.L.C. | BSP | P | 04/11/2017 | front porch lid/side porch lid/deck ok -- letter on file for framing changes on deck/porches | SCOTTS | SCOTTS | | BSP | P | 5471286 |
SC SCOTT CONSTRUCTION CONSULTING, L.L.C. | BSP | P | 04/11/2017 | portal wall ok/letter on file for trimmers/kings | SCOTTS | SCOTTS | | BSP | P | 5471282 |
SC SCOTT CONSTRUCTION CONSULTING, L.L.C. | BSP | P | 02/14/2017 | 4 deck piers OK | DAKOTAB | DAKOTAB | | BSP | P | 5415014 |
SC SCOTT CONSTRUCTION CONSULTING, L.L.C. | BFT | C | 02/09/2017 | Engineers observation Letter on file / note - exterior piers were not inspected | BRIANB | BRIANB | | BFT | C | 5410570 |
SC SCOTT CONSTRUCTION CONSULTING, L.L.C. | BFD | C | 02/06/2017 | | DALE | DALE | | BFD | C | 5407676 |
SC SCOTT CONSTRUCTION CONSULTING, L.L.C. | BFI | C | 02/06/2017 | | DALE | DALE | | BFI | C | 5407675 |
SC SCOTT CONSTRUCTION CONSULTING, L.L.C. | BFN | C | 02/06/2017 | ok per eng. / all paperwork on file / float / 3000 psf | DALE | DALE | | BFN | C | 5407674 |
SC SCOTT CONSTRUCTION CONSULTING, L.L.C. | BSP | T | 01/12/2017 | PAID (REC#1395090) ADDITIONAL PLAN REVIEW TIME: $50 From: JUSTINC Splice to revise duct design and duct summary sheet | JUSTINC | JUSTINC | | BSP | T | 5387477 |
SC SCOTT CONSTRUCTION CONSULTING, L.L.C. | BFT | P | 01/10/2017 | AUTHORIZED INSPECTION BY ENGINEER | NELIDA | NELIDA | NELIDA | BFT | P | 5385627 |
SC SCOTT CONSTRUCTION CONSULTING, L.L.C. | BFN | P | 01/10/2017 | AUTHORIZED INSPECTION BY ENGINEER | NELIDA | NELIDA | NELIDA | BFN | P | 5385626 |
FIRST RATE ELECTRICAL SERVICES, INC. | E= | C | 08/17/2017 | | CRAIG | CRAIG | | E= | C | 5598614 |
FIRST RATE ELECTRICAL SERVICES, INC. | E= | R | 08/15/2017 | bad gfci garage by panel, blocking in garage to protect cable. (blocking must be above cable in wall space) note: 30 amp a/c hot tub pre-wire | BRET | BRET | | E= | R | 5596608 |
FIRST RATE ELECTRICAL SERVICES, INC. | ER | C | 05/30/2017 | turn into j box - outlet of the closet circuit ok | CRAIG | CRAIG | | ER | C | 5520208 |
FIRST RATE ELECTRICAL SERVICES, INC. | ES | C | 05/26/2017 | Residential Underground: 200 - amp 3 Wire service, ok to seal meter / | CRAIG | CRAIG | | ES | C | 5518820 |
FIRST RATE ELECTRICAL SERVICES, INC. | ER | R | 05/26/2017 | remove bath outlet from master closet ---------- no mcc 2 - 10/3 4 - 6/3 al 4/w #2 al to sub panel No Cent Vac / Irreversible UFER connection / Finished Basement / | CRAIG | CRAIG | | ER | R | 5518818 |
FIRST RATE ELECTRICAL SERVICES, INC. | EUG | C | 05/05/2017 | | JOSEPH | JOSEPH | | EUG | C | 5497779 |
REGIONAL HEATING AND AIR CONDITIONING, INC. | H= | C | 08/29/2017 | finished basement, high/low combustion air to mechanical room, 6" outside air to return, direct vent furnace, a/c complete, no mantel. | PAULO | PAULO | | H= | C | 5610600 |
REGIONAL HEATING AND AIR CONDITIONING, INC. | HC | C | 05/26/2017 | RELEASE METER | PAULO | PAULO | | HC | C | 5518391 |
REGIONAL HEATING AND AIR CONDITIONING, INC. | HRR | C | 05/26/2017 | corrections made. note: finished basement, 6" outside air to return, direct vent furnace, a/c rough and line set, duct design. | PAULO | PAULO | | HRR | C | 5518384 |
REGIONAL HEATING AND AIR CONDITIONING, INC. | HRR | P | 05/25/2017 | need the following-- missing R.A. headers in basement, complete bath fan exhaust duct to termination in basement bath. rest ok. NEEDED BY FINAL-- S.A. DUCT NOT CONNECTED IN MECHANICAL ROOM, SEAL ALL DUCTING AND PLENUMS IN MECHANICAL ROOM. note: finished basement, 6" outside air to return, direct vent furnace, a/c rough and line set, duct design. | PAULO | PAULO | | HRR | P | 5517352 |
UNIQUE RADIANT HTG. & PLBG. | HI | C | 05/03/2017 | 10# test ok. note: 1 1/4" main at 80' to furnace, water heater, fire place and future 3/4" stub under deck. | PAULO | PAULO | | HI | C | 5494805 |
UNIQUE RADIANT HTG. & PLBG. | P= | C | 09/14/2017 | Certification of potable water to scanning. | CRADE | CRADE | | P= | C | 5626064 |
UNIQUE RADIANT HTG. & PLBG. | P= | P | 09/08/2017 | Need certificate of potable water.Rest ok.Note:finished basement,mixing valve at tub access,RP installed in mech room. | CRADE | CRADE | | P= | P | 5620385 |
UNIQUE RADIANT HTG. & PLBG. | PWO | C | 04/25/2017 | Corrections made. | CRADE | CRADE | | PWO | C | 5486515 |
UNIQUE RADIANT HTG. & PLBG. | PTO | C | 04/25/2017 | Note:finished basement,laundry sink aav,master lav aav,vtr. | CRADE | CRADE | | PTO | C | 5486509 |
UNIQUE RADIANT HTG. & PLBG. | PWO | P | 04/20/2017 | Sleeve shall be two pipe sizes greater than the pipe passing through the wall. | CRADE | CRADE | | PWO | P | 5481861 |
UNIQUE RADIANT HTG. & PLBG. | PB | C | 02/15/2017 | DWV ON TEST , NO WATER IN | GABE | GABE | | PB | C | 5416395 |