SOLID ROCK CONSTRUCTION, LLC | B= | C | 10/27/2017 | Rear stairs have been removed, a guard railing has been installed at the rear sliding door. | BERTW | BERTW | | B= | C | 5669749 |
SOLID ROCK CONSTRUCTION, LLC | B= | P | 10/12/2017 | missing min. 36" landing (height of landing over 30") at the rear west sliding glass door / other corrections from the previous inspection are okay -- Schedule a new Building Final when above items are complete. | BRIANB | BRIANB | | B= | P | 5653376 |
SOLID ROCK CONSTRUCTION, LLC | B= | R | 10/12/2017 | observation letter for helical piers at rear deck on file / manufacture install documentation for decking on file / still need to perform building final re-inspection -- Schedule a new Building Final when above items are complete. | BRIANB | BRIANB | | B= | R | 5652715 |
SOLID ROCK CONSTRUCTION, LLC | B= | R | 09/29/2017 | Rear deck was not previously inspected, Rear deck frame inspected at Final, need helical piers documentation, Need landing at bottom of stairs for deck and rear stairs, straps needed at stringers at rear stairs, need post to beam connections on posts for deck,handrail is not secured at rear deck, need manufacture installation requirements for composite decking, stairs stringers are 15" apart. Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | NOAH | NOAH | | B= | R | 5640756 |
SOLID ROCK CONSTRUCTION, LLC | BLA | P | 06/26/2017 | extend light box in pop out on front porch -- garage needs separate permit for stucco/lath on garage is ok | SCOTTS | SCOTTS | | BLA | P | 5546573 |
SOLID ROCK CONSTRUCTION, LLC | BIN | C | 06/16/2017 | | JUSTINL | JUSTINL | | BIN | C | 5538205 |
SOLID ROCK CONSTRUCTION, LLC | BFR | C | 06/16/2017 | Corrections made | JUSTINL | JUSTINL | | BFR | C | 5538204 |
SOLID ROCK CONSTRUCTION, LLC | BFR | R | 06/14/2017 | not dried in/missing roof jacks -- missing ST22's -- missing ST18's front window configuration at trimmers -- draftstop dropped ceiling/soffit in bedroom 2 | SCOTTS | SCOTTS | | BFR | R | 5536125 |
SOLID ROCK CONSTRUCTION, LLC | BSP | P | 05/25/2017 | front porch frame and posts ok | DALE | DALE | | BSP | P | 5517804 |
SOLID ROCK CONSTRUCTION, LLC | BSP | P | 05/23/2017 | Need ledger detail for front deck -- (2) 2x10 beam on east side of porch not secured to post at corner -- Plans call for (2) H2.5's at C1 mid point bearing -- Missing LS90 at west corner where both (2) 2x10 beams meet | DAKOTAB | DAKOTAB | | BSP | P | 5514217 |
SOLID ROCK CONSTRUCTION, LLC | BFD | C | 05/16/2017 | Engineers observation Letter on file | BRIANB | BRIANB | | BFD | C | 5507208 |
SOLID ROCK CONSTRUCTION, LLC | BFD | R | 04/21/2017 | the interior drain trench is not installed min. 12" away from the footing / missing min. 4" of clean gravel from the top of the footing per underslab drain details / could not verify outfall for the underslab drain or connection to sump pit - connection covered / okay to use engineer to do inspection if needed - will need to provide stamped observation letter | BRIANB | BRIANB | | BFD | R | 5483457 |
SOLID ROCK CONSTRUCTION, LLC | BFN | C | 03/29/2017 | inspection completed 3/28 | BRIANB | BRIANB | | BFN | C | 5458681 |
SOLID ROCK CONSTRUCTION, LLC | BFT | C | 03/29/2017 | inspection completed 3/28 | BRIANB | BRIANB | | BFT | C | 5458680 |
SOLID ROCK CONSTRUCTION, LLC | BFD | P | 03/28/2017 | Drain is Usable, Over ex and Underslab to pit. Partial perimeter drain inspected. Engineer observation for Over ex received. Need engineer observation or inspection for usable crawlspace and underslab drain. Damp proofing ok. | JUSTINL | JUSTINL | | BFD | P | 5457686 |
SOLID ROCK CONSTRUCTION, LLC | BFN | C | 03/28/2017 | Engineer letter for foundation received-- Eufer noted -- Foundation design received | JUSTINL | JUSTINL | | BFN | C | 5457670 |
SOLID ROCK CONSTRUCTION, LLC | BFT | C | 03/28/2017 | Engineer letter for footing received -- Open hole, Over ex and Soils report received -- 2000PSF - Drain Perimeter, Underslab and Over ex. - 10% | JUSTINL | JUSTINL | | BFT | C | 5457658 |
D & J QUALITY ELECTRIC INC | E= | C | 09/27/2017 | house ok | CRAIG | CRAIG | | E= | C | 5638548 |
D & J QUALITY ELECTRIC INC | E= | P | 09/26/2017 | need permit for detached garage | CRAIG | CRAIG | | E= | P | 5637780 |
D & J QUALITY ELECTRIC INC | E= | R | 09/12/2017 | grd j box on west wall of garage with al wires ----------- install 250 . 94 -------------- note feeder to detached garage is not inside detached garage or inside house | CRAIG | CRAIG | | E= | R | 5623917 |
D & J QUALITY ELECTRIC INC | ES | C | 09/12/2017 | Residential Underground: 200 - amp 3 Wire new service, ok to seal meter / | CRAIG | CRAIG | | ES | C | 5623916 |
D & J QUALITY ELECTRIC INC | EUG | C | 07/21/2017 | 2/0al feeder with #4al ground------------ -------------- need permit for separate structure before final | MATTHEW | MATTHEW | | EUG | C | 5571757 |
D & J QUALITY ELECTRIC INC | EP | R | 07/19/2017 | install equipment ground; ---------------- need separate permit for detached garage | MATTHEW | MATTHEW | | EP | R | 5568983 |
D & J QUALITY ELECTRIC INC | ER | C | 06/13/2017 | | MATTHEW | MATTHEW | | ER | C | 5533575 |
D & J QUALITY ELECTRIC INC | ES | R | 06/09/2017 | see rough notes | MATTHEW | MATTHEW | | ES | R | 5530819 |
D & J QUALITY ELECTRIC INC | ER | R | 06/09/2017 | seal return air in soffit above door to under stair storage, nail plate at bottom plate as you go down the stairs------------- call me about the wire bending space for 350kcmil------------------ finished basement, no mcc's, no vac, non-ir ufer | MATTHEW | MATTHEW | | ER | R | 5530818 |
D & J QUALITY ELECTRIC INC | EUG | C | 04/07/2017 | 3/w 350 mcm al | CRAIG | CRAIG | | EUG | C | 5468309 |
A & Z MECHANICAL, INC. | H= | C | 09/25/2017 | finished basement, high/low combustion air to mechanical room, 6" outside air to return, no a/c, mantel ok. | PAULO | PAULO | | H= | C | 5636168 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | HO | C | 06/14/2017 | 10# test ok. note: 3/4" poly at 90' to garage (not to exceed 123k), tracer wire installed. | PAULO | PAULO | | HO | C | 5535635 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | HC | C | 06/06/2017 | RELEASE METER | ACE | ACE | | HC | C | 5526692 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | HI | C | 06/06/2017 | 10# test ok, 1 1/4" main, 1 furn, 1 w/h, 1 fp, 1 range. | ACE | ACE | | HI | C | 5526691 |
A & Z MECHANICAL, INC. | HRR | C | 06/06/2017 | NOTES: direct vent furnace, duct design and equip cert ok. no AC, osa to return, finished basement. | ACE | ACE | | HRR | C | 5526690 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | P= | C | 09/22/2017 | finished basement, certificate of potable water to scanning, no sprinkler stub | TED | TED | | P= | C | 5634578 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | PTO | C | 06/02/2017 | Note:finished basement,mixing valve at master lav,vtr. | CRADE | CRADE | | PTO | C | 5524464 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | PWO | C | 05/02/2017 | ok,H20 under footer.Need certification of potable water by final. | CRADE | CRADE | | PWO | C | 5493543 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | PB | C | 04/17/2017 | ok,No water stubbed into foundation at this point | CRADE | CRADE | | PB | C | 5477846 |