HOMEOWNER | BE | L | 10/08/2021 | Renewed for $248 at 10/8/2021 10:52:00 AM | SIERRAC | SIERRAC | | BE | L | 7135158 |
HOMEOWNER | BIN | C | 02/08/2021 | | JEREMYD | JEREMYD | | BIN | C | 6862968 |
HOMEOWNER | BFR | C | 02/03/2021 | Updated foundation design and letter addressing previous BSP items on file / Frame ok. | JEREMYD | JEREMYD | | BFR | C | 6858131 |
HOMEOWNER | BFR | P | 01/25/2021 | Need to fireblock throughout - seal all penetrations through top plate / Missing blocking under garage door brackets / Front porch lid ok / Rest of Frame ok. | JEREMYD | JEREMYD | | BFR | P | 6847374 |
HOMEOWNER | BE | L | 11/06/2020 | Renewed for No Fee at 11/6/2020 10:41:05 AM | VERONIKAP | VERONIKAP | | BE | L | 6767700 |
HOMEOWNER | BE | L | 05/04/2020 | Renewed for No Fee at 5/4/2020 8:25:25 AM | TERRI | TERRI | | BE | L | 6559300 |
HOMEOWNER | BLA | C | 04/17/2019 | | DALE | DALE | | BLA | C | 6168546 |
HOMEOWNER | BSP | P | 03/07/2019 | wall at front porch not on plans | DALE | DALE | | BSP | P | 6126521 |
HOMEOWNER | BSP | P | 03/05/2019 | need plans for depressed wall at front porch, not per plans | DALE | DALE | | BSP | P | 6124243 |
HOMEOWNER | BSP | P | 09/11/2018 | depressed wall at porch shows on on interior, 2 porch piers ok | DALE | DALE | | BSP | P | 5960884 |
HOMEOWNER | BSP | R | 08/24/2018 | depressed foundation wall shown on plans not piers/provide letter for change to piers -- piers currently 18" diameter | SCOTTS | SCOTTS | | BSP | R | 5945024 |
HOMEOWNER | BFN | C | 03/30/2018 | Foundation forms with reinforcement okay / Plans reviewed on site | SHAUN | SHAUN | | BFN | C | 5803837 |
HOMEOWNER | BFT | C | 03/30/2018 | 3- 36" interior pads okay | SHAUN | SHAUN | | BFT | C | 5803832 |
HOMEOWNER | BFN | R | 03/28/2018 | Provide page 3 of the foundation design then recall inspection | SHAUN | SHAUN | | BFN | R | 5801538 |
HOMEOWNER | BFT | R | 03/28/2018 | Provide page 3 of the foundation design then recall inspection | SHAUN | SHAUN | | BFT | R | 5801529 |
HOMEOWNER | BFT | R | 01/02/2018 | Dogs running loose on property, No one on site | SHAUN | SHAUN | | BFT | R | 5726900 |
HOMEOWNER | BFT | P | 12/29/2017 | Corrections made to Buttress wall // Still need to inspect interior pads | NOAH | NOAH | | BFT | P | 5725307 |
HOMEOWNER | BFT | P | 12/29/2017 | Missing reinforcement at buttress wall // Still need to inspect interior pads // Soils report and open hole received pending upload // 1500 PSF verified // drain not required // 1% grade | NOAH | NOAH | | BFT | P | 5725096 |
HOMEOWNER | BE | L | 08/14/2017 | Renewed at 8/14/2017 12:24:16 PM | JANE | JANE | | BE | L | 5594812 |
HOMEOWNER | E= | C | 09/29/2022 | Corrections with KO, wire to WH, TR receptacles, circuit to island, and AFCI/GFCI protection okay - complete | CHIPO | CHIPO | | E= | C | 7534788 |
HOMEOWNER | E= | R | 04/22/2022 | install TR / WR exterior plugs ------------ install # 10 from water heater disconnect to water heater / also install KO plug ---------------- install TR plug for laundry plug and AFCI / GFI also ---------------- install dedicated 20 amp circuit to island -------------------- AFCI kitchen lights ------------------ 14/2 wire on 20 ampo breaker needs to be on 15 amp breake | CRAIG | CRAIG | | E= | R | 7349888 |
HOMEOWNER | EP | C | 11/04/2019 | 150 amp 4/w to house sub panel ok | CRAIG | CRAIG | | EP | C | 6387999 |
HOMEOWNER | ES | C | 11/04/2019 | Residential Underground: 150-amp 3 Wire New Residence ok to set meter. / | CRAIG | CRAIG | | ES | C | 6387998 |
HOMEOWNER | EUG | C | 08/20/2019 | 2 1/2" pvc from out building to house | CRAIG | CRAIG | | EUG | C | 6307625 |
HOMEOWNER | ER | C | 05/10/2019 | corrections made | MATTHEW | MATTHEW | | ER | C | 6195054 |
HOMEOWNER | ER | R | 04/17/2019 | install p[lug in hallway -------- install fan boxes in all bedrooms ---------- install counter top plug left of fridge and range plug 120 v ------------ crawl space / no mcc / 2 - 10/3 8/2 cu / no cen vac -------- Discussed AFCI/GFCI/TR/Dedicated 20 amp to bath plugs / Laundry plug / 2 small appliance requirements with owner. / | CRAIG | CRAIG | | ER | R | 6169365 |
HOMEOWNER | H= | C | 12/06/2022 | NOTE / CONDITIONED CRAWL SPACE / OUTSIDE AIR WITH DAMPER TO FURNACE RETURN / DIRECT VENT FURNACE / ELECTRIC WATER HEATER / | JERAMIEP | JERAMIEP | | H= | C | 7601537 |
EDISON PROPANE LLC | HO | C | 12/10/2021 | 10 LB TEST OK / 70' OF 3/4" POLY PIPE WITH TRACER WIRE FROM TANK LOCATION TO REGULATOR LOCATION / | BILLS | BILLS | | HO | C | 7204851 |
HOMEOWNER | HI | C | 01/22/2021 | 10 LB TEST OK / 3/4 INCH MAIN / 1 FURNACE / 1 RANGE / NEED TO SEE GAS APPLIANCES CONVERTED TO LP BY FINAL / | GREGV | GREGV | | HI | C | 6846600 |
HOMEOWNER | HRR | C | 01/22/2021 | CORRECTIONS MADE / BY FINAL NEED PLAN SPLICE FOR CHANGES TO RETURN AIR (DRAWN AS WALL RETURNS, INSTALLED AS CEILING RETURNS / NEED EQUIPMENT CHANGE LETTER FOR FURNACE (PLANS CALL FOR GOODMAN, LENNOX INSTALLED,/ BY FINAL, MISSING PASSIVE RETURN AIR OPENING FOR CRAWLSPACE CONDITIONING, INSULATE OUTSIDE AIR. NOTE: CONDITIONED CRAWLSPACE, DIRECT VENT FURNACE, NO A/C, OUTSIDE AIR TO FURNACE RETURN, HIGH/LOW COMBUSTION AIR FROM OUTSIDE TO MECHANICAL ROOM, ELECTRIC WATER HEATER | GREGV | GREGV | | HRR | C | 6846598 |
HOMEOWNER | HRR | P | 01/05/2021 | NO CORRECTIONS MADE. SEE INSPECTION NOTES FROM 10-9-2019 NEED GAS INSPECTION ALSO | BILLS | BILLS | | HRR | P | 6825273 |
HOMEOWNER | HRR | P | 10/09/2019 | ***updated 10/10/19 by Bill S. by final: remove or permanently seal crawlspace vents as all of the heat and energy calc's show the crawlspace as conditioned, not vented***NEED TO RESEARCH THE VENTED/CONDITIONED CRAWLSPACE AND THE ADDITION OF THE HIGH/LOW COMBUSTION AIR FROM OUTSIDE TO MECHANICAL ROOM. WILL UPDATE INSPECTION ON THE FOLLOWING MORNING. NEED PLAN SPLICE FOR CHANGES TO RETURN AIR (DRAWN AS WALL RETURNS, INSTALLED AS CEILING RETURNS,NEED EQUIPMENT CHANGE LETTER FOR FURNACE (PLANS CALL FOR GOODMAN, LENNOX INSTALLED) MISSING PASSIVE RETURN AIR OPENING FOR CRAWLSPACE CONDITIONING, INSULATE OUTSIDE AIR. NOTE: VENTED/CONDITIONED CRAWLSPACE, DIRECT VENT FURNACE, NO A/C, OUTSIDE AIR TO FURNACE RETURN, HIGH/LOW COMBUSTION AIR FROM OUTSIDE TO MECHANICAL ROOM, ELECTRIC WATER HEATER | BILLS | BILLS | | HRR | P | 6363210 |
HOMEOWNER | HRR | P | 08/20/2019 | Equipment installed does not match equipment listed on approved duct design. Contractor must fill out the Equipment Change Form (Residential) and attach form to an inspection request by final. Form can be found on the PPRBD website under Downloads, Residential Handouts, Equipment Change Residential Duct Design. / . BY FINAL PROVIDE DUCT LEAKAGE REPORT. WILL NEED UPDATED DUCT DESIGN SPLICED TO SHOW SUPPLIES IN THE ATTIC. INSULATE END CAP OF SUPPLY TRUNK IN ATTIC. B VENT INSULATION SHIELD IS TOO SHORT. INSULATE OUTSIDE AIR TO RETURN. PROVIDE SUPPLY FOR CONDITIONED CRAWLSPACE. NOTES: OUTSIDE AIR TO RETURN, 6" HIGH/LOW COMBUSTION, A/C ROUGH COIL AND LINE SET, CONDITIONED CRAWLSPACE. | KYLEW | KYLEW | | HRR | P | 6306784 |
HOMEOWNER | P= | C | 12/06/2022 | correction made | ANTHONYT | ANTHONYT | | P= | C | 7601714 |
HOMEOWNER | P= | P | 12/05/2022 | Upload a photo of the T&P drain terminating to the water heater drain pan / Rest OK / Photo upload requested. If unfamiliar with uploading photos for an inspection, please click the following link: https://youtu.be/QS0hdGSBA6o /// NOTE: DRAIN PAN TERMINATES TO HUB DRAIN IN CRAWLSPACE VIA AIR GAP | ADRIANM | ADRIANM | | P= | P | 7599938 |
HOMEOWNER | P= | P | 12/02/2022 | need aav at kitchen sink / fix leak at kitchen sink garbadge disposal / need air gaps at water heater T&P and condensate drain for furnace / secure and seal exterior hose bibs / rest ok | ANTHONYT | ANTHONYT | | P= | P | 7598716 |
HOMEOWNER | PTO | C | 01/22/2021 | correction made, will check mechanical floor drain at final, note: water supply is from private community well system | TED | TED | | PTO | C | 6846413 |
HOMEOWNER | PTO | R | 01/07/2021 | can not mix abs and pvc, both showers are horizontal dry vented, vent mech. room floor drain, support and separate hot and cold pex lines in crawlspace, | TED | TED | | PTO | R | 6829228 |
HOMEOWNER | XBS | P | 03/06/2019 | PLAN SPLICE: (No Fee) by: MICHAELA for Construction: Foundation clarification | MICHAELA | MICHAELA | | XBS | P | 6125375 |