JERRY'S CUSTOM CONCRETE | B= | C | 05/25/2017 | Previous items corrected / CO Insignia 31955 | RICHB | RICHB | | B= | C | 5517282 |
JERRY'S CUSTOM CONCRETE | B= | P | 05/24/2017 | guard at stairs must be 36" or greater in height -- handrail to basement need returns -- rest ok -- Schedule a new Building Final when above items are complete. | SCOTTS | SCOTTS | | B= | P | 5515607 |
JERRY'S CUSTOM CONCRETE | B= | R | 05/23/2017 | attach State licensed installer to permit and recall | SCOTTS | SCOTTS | | B= | R | 5513968 |
JERRY'S CUSTOM CONCRETE | BTD | C | 05/10/2017 | Engineering letter received - AB spacing is 48" max, no plate washers, 2x6 beam bearing OK / manufacturer installation paperwork now on-site / walked with contractor to verify work / plans reviewed electronically / Unit SN 16-M33292 | RICHB | RICHB | | BTD | C | 5501632 |
JERRY'S CUSTOM CONCRETE | BTD | R | 04/25/2017 | Per accepted plans need anchor bolts at 3' OC max - 1/2" diam with 3x3 plate washer / beam bears on 2x6 at each end - not per plans / marriage line not attached per CO Handbook - no manufacturer installation book on-site / plans reviewed electronically | RICHB | RICHB | | BTD | R | 5486254 |
JERRY'S CUSTOM CONCRETE | BSP | R | 04/18/2017 | upload clean copy of detail for in fill of window -- in fill ok | SCOTTS | SCOTTS | | BSP | R | 5479231 |
JERRY'S CUSTOM CONCRETE | BFI | C | 03/31/2017 | 2" R10 @ 32" | SCOTTS | SCOTTS | | BFI | C | 5461303 |
JERRY'S CUSTOM CONCRETE | BFD | C | 03/29/2017 | drain useable -- daylights to west from SW and NW corners | SCOTTS | SCOTTS | | BFD | C | 5458673 |
JERRY'S CUSTOM CONCRETE | BFT | C | 03/14/2017 | open hole observation / 1500 psf | ERICR | ERICR | | BFT | C | 5439814 |
JERRY'S CUSTOM CONCRETE | BFN | C | 03/14/2017 | open hole observation / 1500 psf | ERICR | ERICR | | BFN | C | 5439813 |
JERRY'S CUSTOM CONCRETE | BFN | P | 03/13/2017 | foundation reinforcement ok / ufer ok / need open hole observation / pour at own risk | ERICR | ERICR | | BFN | P | 5439703 |
JERRY'S CUSTOM CONCRETE | BFT | P | 03/06/2017 | pending open hole observation/pour at own risk | SCOTTS | SCOTTS | | BFT | P | 5432036 |
ELK CREEK ELECTRICAL COMPANY LLC | E= | C | 05/22/2017 | AC is pre roughed
| JOSEPH | JOSEPH | | E= | C | 5513309 |
ELK CREEK ELECTRICAL COMPANY LLC | E= | P | 05/19/2017 | New exterior receptacle is missing interior cover. ------------ Ejector pit outlet needs GFCI protection ------------ Label sub - panel directory.---------- Cover open wiring at exterior. - Tag feeders to future outbuilding "Future use only." Notes: 100 amp sub panel good --------- AC is factory wired. -------- | JOSEPH | JOSEPH | | E= | P | 5511431 |
ELK CREEK ELECTRICAL COMPANY LLC | E= | R | 05/03/2017 | Need UFER by final ---------- Strap riser ---------- Basement and stairway not wired yet. ------- Notes: 2 Rods | JOSEPH | JOSEPH | | E= | R | 5494443 |
ELK CREEK ELECTRICAL COMPANY LLC | ES | C | 05/03/2017 | Residential Overhead: 200 amp 3w new res. need meter set | JOSEPH | JOSEPH | | ES | C | 5494430 |
ELK CREEK ELECTRICAL COMPANY LLC | EUG | C | 05/02/2017 | 4th wire from utility pole to home will not be used at this time. | JOSEPH | JOSEPH | | EUG | C | 5493098 |
PLAINS HEATING AND AIR CONDITIONING, INC. | H= | C | 05/18/2017 | corrections made. note: unfinished basement, direct vent down flow furnace, direct vent water heater, no a/c, mantel ok. | PAULO | PAULO | | H= | C | 5510186 |
PLAINS HEATING AND AIR CONDITIONING, INC. | H= | P | 05/16/2017 | need the following-- proper support to S.A. ducts, 1- S.A. duct is just dangling (not sure where it goes). rest ok. note: unfinished basement, direct vent down flow furnace, direct vent water heater, no a/c, mantel ok. | PAULO | PAULO | | H= | P | 5507450 |
PLAINS HEATING AND AIR CONDITIONING, INC. | HC | C | 05/16/2017 | RELEASE METER | PAULO | PAULO | | HC | C | 5507448 |
PLAINS HEATING AND AIR CONDITIONING, INC. | HRR | C | 05/16/2017 | unfinished basement, direct vent down flow furnace, direct vent water heater, no a/c. | PAULO | PAULO | | HRR | C | 5507443 |
MD SERVICE PLUMBING, INC. | HO | C | 05/11/2017 | 10# test ok. note: 1/2" poly at 70' to home, tracer wire installed. L.P. | PAULO | PAULO | | HO | C | 5502909 |
MD SERVICE PLUMBING, INC. | HI | C | 05/10/2017 | 3/4'' black iron piping, L.P. system, furnace, water heater, fireplace | TED | TED | | HI | C | 5502214 |
HOMEOWNER | HO | R | 05/04/2017 | not ready. low test. need the following-- minimum of a 10# test on 30# test gage. no test through the regulator. note: 1/2" poly at 70' to home, tracer wire installed. L.P. | PAULO | PAULO | | HO | R | 5495826 |
AFAB PLUMBING LLC | P= | C | 05/17/2017 | correction made | TED | TED | | P= | C | 5509708 |
AFAB PLUMBING LLC | P= | P | 05/17/2017 | certificate of potable water to scanning | TED | TED | | P= | P | 5508510 |
AFAB PLUMBING LLC | P= | R | 05/10/2017 | install aav on both basement lavs, install trap guard on basement floor drain, need certificate of potable water | TED | TED | | P= | R | 5502204 |
AFAB PLUMBING LLC | PTO | C | 05/10/2017 | unfinished basement | TED | TED | | PTO | C | 5502199 |
JERRY'S CUSTOM CONCRETE | PWO | C | 04/12/2017 | ok,H20 sleeved thru foundation,Need certification of potable water by finale. | CRADE | CRADE | | PWO | C | 5472403 |
AFAB PLUMBING LLC | PB | C | 04/06/2017 | ok.Note:basement bath into ejector pit.no pwo at this point,need certification of potable water by final. | CRADE | CRADE | | PB | C | 5466196 |