VICTORY CONSTRUCTION AND REFRIGERATION LLC. | B= | C | 02/27/2018 | All other required Final inspections are complete. (This is a computer generated result) | JEREMYA | JEREMYA | | B= | C | 5775733 |
VICTORY CONSTRUCTION AND REFRIGERATION LLC. | B= | P | 02/27/2018 | Letter for RTU framing on file. Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet, External Agency Inspection Z= by WOODLAND PARK is not Completed yet (Contact: Deidra Arnold at 719-687-5202 or Lisa Parnell at 719-687-5209). | JEREMYA | JEREMYA | | B= | P | 5774753 |
VICTORY CONSTRUCTION AND REFRIGERATION LLC. | BE | L | 09/22/2017 | Renewed at 9/22/2017 3:14:07 PM | JLANE | JLANE | | BE | L | 5634756 |
LONE STAR ELECTRIC LLC | E= | C | 08/24/2017 | | JOHNN | JOHNN | | E= | C | 5606353 |
LONE STAR ELECTRIC LLC | ER | P | 04/25/2017 | wall:double combo oven pipes,stubbed to ceiling,need to see grds made up on next rough, | JOHNN | JOHNN | | ER | P | 5487082 |
LONE STAR ELECTRIC LLC | ER | L | 04/25/2017 | need electrician on site and contact # | JOHNN | JOHNN | | ER | L | 5485914 |
REEVES SPECIALTY SERVICES, INC. | H= | C | 11/27/2017 | ALL OK | JERRYF | JERRYF | | H= | C | 5694035 |
OLSON PLUMBING & HEATING COMPANY | H= | C | 11/27/2017 | ALL OK | JERRYF | JERRYF | | H= | C | 5694034 |
OLSON PLUMBING & HEATING COMPANY | HC | P | 11/14/2017 | pending mua permit | DAVIDH | DAVIDH | | HC | P | 5684298 |
OLSON PLUMBING & HEATING COMPANY | H= | P | 11/14/2017 | permit mua unit | DAVIDH | DAVIDH | | H= | P | 5684290 |
OLSON PLUMBING & HEATING COMPANY | HI | P | 11/14/2017 | 10 lb test ok note still need permit for mua unit secured | DAVIDH | DAVIDH | | HI | P | 5684289 |
REEVES SPECIALTY SERVICES, INC. | H= | P | 09/26/2017 | TAB REPORT RECEIVED - STILL NEED GAS LINE PERMITTED / INSTALLED AND INSPECTED | JERRYF | JERRYF | | H= | P | 5636626 |
REEVES SPECIALTY SERVICES, INC. | H= | P | 09/26/2017 | LETTER RECEIVED FOR INTERLOCKS - STILL NEED OTHER ITEMS ADDRESSED | JERRYF | JERRYF | | H= | P | 5636592 |
REEVES SPECIALTY SERVICES, INC. | H= | P | 09/08/2017 | PARTIAL PENDING THE FOLLOWING - TAB REPORT - LETTER VERIFYING INTERLOCKS ARE IN FULL OPERATION - THIS CONTRACTORS WORK WILL BE COMPLETE AFTER TAB AND LETTER - WILL NEED GAS CONTRACTOR ATTACHED AND GAS COMPLETED TO NEW MUA PER PLAN - OR REVISE PLAN DELETING GAS | JERRYF | JERRYF | | H= | P | 5619865 |
REEVES SPECIALTY SERVICES, INC. | H= | R | 08/31/2017 | NOTES ADDED AT 7:20 ON 9/1 - CONTRACTOR TO BE ON SITE TO VERIFY INTERLOCKS AT HOOD PER SHEET M2 - WAIVED TRIP FEE - NEED HINGE KIT AND GASKET AT FAN - LABEL ALL ROOF EQUIPMENT TO UNITS SERVED - LARGE GAPS BEHIND HOOD AT METAL - NEED 18" CLEARANCE TO COMBUSTIBLES FROM HOOD - TAB REPORT - STOPPED INSPECTION MAY BE MORE | JERRYF | JERRYF | | H= | R | 5612577 |
REEVES SPECIALTY SERVICES, INC. | H= | R | 08/25/2017 | NO LADDER FOR ACCESS TO TOP OF HOOD - APPEARS METAL BEHIND HOOD IS NOT SECURED - METAL COMING OFF BELOW HOOD - NEED INTERLOCKS - ROOF INSPECTION - STOPPED INSPECTION MAY BE MORE | JERRYF | JERRYF | | H= | R | 5607027 |
REEVES SPECIALTY SERVICES, INC. | HD | P | 05/15/2017 | NEED METAL ELBOW INSTALLED AT MUA CONNECTION TO MAINTAIN 18" CLEARANCE TO TOP OF HOOD - CANNOT HAVE SCREWS IN STAINLESS STEEL BELOW HOOD NEED TO REPLACE 45 DEGREE ANGLE AND SECURE TO WALL WITHOUT SCREWS OR EXPOSED SEALANT - NEED TO SEAL ALL STAINLESS ABOVE AND BEHIND HOOD AT ALL SHEET ROCK AREA'S SOME AREA'S HAVE GAPS AT JOINTS - BY FINAL NEED ROOF INSPECTION - TAB REPORT | JERRYF | JERRYF | | HD | P | 5506467 |
REEVES SPECIALTY SERVICES, INC. | HD | P | 05/12/2017 | GREASE DUCT WRAP COMPLETE FOR 2 LAYERS, BANDING AND CLEAN OUTS. | MARKB | MARKB | | HD | P | 5504447 |
REEVES SPECIALTY SERVICES, INC. | HD | P | 05/11/2017 | GREASE DUCT LIGHT TEST - COMPLETE FROM CURB DOWN TO HOOD. CURB DROP IS WRAPPED - OK TO WRAP REST 2 LAYERS WITH PICTURES OF FIRST LAYER. | MARKB | MARKB | | HD | P | 5503526 |
REEVES SPECIALTY SERVICES, INC. | HD | L | 05/10/2017 | NOT READY - NEED ALL OPEN INTERIOR SEAMS WELDED AND GROUND SMOOTH - WILL NEED AREA BLACKED OUT WITH DARK PLASTIC FOR THIS INSPECTION SINCE LIGHTS CANNOT BE TURNED OF - ALL READY RESCHEDULED FOR 5/11 FOR AM INSPECTION | JERRYF | JERRYF | | HD | L | 5501605 |
REEVES SPECIALTY SERVICES, INC. | HD | P | 04/27/2017 | GREASE DUCT LIGHT TEST - TEST FOR CURB DROP DONE ON FLOOR OK TO WRAP AND DROP THROUGH ROOF | MARKB | MARKB | | HD | P | 5489563 |
REEVES SPECIALTY SERVICES, INC. | HD | P | 04/27/2017 | HOOD WALL FRAMING OK | JERRYF | JERRYF | | HD | P | 5488847 |
H2O PLUMBING & HEATING, INC. | P= | C | 08/23/2017 | corrections made. | TAYLOR | TAYLOR | | P= | C | 5604581 |
H2O PLUMBING & HEATING, INC. | P= | P | 08/22/2017 | need to seal and rodent proof vent termination, rest ok. | TAYLOR | TAYLOR | | P= | P | 5603185 |
H2O PLUMBING & HEATING, INC. | PTO | C | 05/09/2017 | check vent termination, backflow, and water lines to filtration system by final. | TAYLOR | TAYLOR | | PTO | C | 5500770 |
H2O PLUMBING & HEATING, INC. | PTO | P | 05/04/2017 | complete water lines in wall and all venting. | TAYLOR | TAYLOR | | PTO | P | 5496090 |
H2O PLUMBING & HEATING, INC. | PB | C | 05/04/2017 | revise plans to show connection to existing 3 inch S.S. by final. | TAYLOR | TAYLOR | | PB | C | 5496088 |
H2O PLUMBING & HEATING, INC. | PTO | R | 05/01/2017 | not ready, note: H2O in wall needs to be properly piped to connect backflow preventer. | TAYLOR | TAYLOR | | PTO | R | 5491947 |
H2O PLUMBING & HEATING, INC. | PB | T | 05/01/2017 | PAID (REC#1421158) not ready, no piping installed. | TAYLOR | TAYLOR | | PB | T | 5491940 |
H2O PLUMBING & HEATING, INC. | PTO | P | 04/25/2017 | above ceiling H2O ok. | TAYLOR | TAYLOR | | PTO | P | 5486215 |