PREMIER HOMES, INC. | B= | C | 08/03/2017 | All other required Final inspections are complete. (This is a computer generated result) | RICHB | RICHB | | B= | C | 5585476 |
PREMIER HOMES, INC. | B= | P | 08/03/2017 | Slab on grade / no deck / AC installed. Additional Inspections Required (computer generated): External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: City Engineering Inspections 719-385-5977). | RICHB | RICHB | | B= | P | 5585326 |
PREMIER HOMES, INC. | BFR | C | 07/27/2017 | UL U375 indicated on splice - material verified in field / plans reviewed electronically | RICHB | RICHB | | BFR | C | 5578093 |
PREMIER HOMES, INC. | BFT | C | 07/27/2017 | Soils & open hole on-file / foundation insulation observation received | RICHB | RICHB | | BFT | C | 5577336 |
PREMIER HOMES, INC. | BFN | C | 07/27/2017 | Foundation plan, soils, open hole and foundation observations received / 2200 psf / ufer noted / | RICHB | RICHB | | BFN | C | 5577334 |
PREMIER HOMES, INC. | BIN | C | 06/12/2017 | | RICHB | RICHB | | BIN | C | 5531937 |
PREMIER HOMES, INC. | BFR | P | 06/12/2017 | Previous items completed / plans reviewed electronically //// UPDATED COMMENT July 18 - Changed to Partial to allow for follow-up / Upon review, need to complete BFT and BFN / need verification that gypsum product used in the separation wall meets UL listing requirements | RICHB | RICHB | | BFR | P | 5531934 |
PREMIER HOMES, INC. | BFR | R | 06/08/2017 | brace strong-back every 4ft / missing point loads at front / ok to insulate | DALE | DALE | | BFR | R | 5530134 |
PREMIER HOMES, INC. | BSP | P | 05/31/2017 | porch frame and posts ok | DALE | DALE | | BSP | P | 5521746 |
SEDLAK ELECTRIC CO. | E= | C | 07/24/2017 | 20 amp a/c | TOMC | TOMC | | E= | C | 5573290 |
SEDLAK ELECTRIC CO. | ES | C | 06/05/2017 | Residential Underground: 150 AMP 3-W NEW RES--OK TO SET METER----NEED UFER ACCESS | BRIAN | BRIAN | | ES | C | 5526180 |
SEDLAK ELECTRIC CO. | ER | C | 06/05/2017 | NOTES--NO CV---6-3 AL OVEN----AC PREWIRE-- | BRIAN | BRIAN | | ER | C | 5526178 |
THE FURNACE GUY HEATING & COOLING | H= | C | 07/26/2017 | Corrections made. | MICHAELS | MICHAELS | | H= | C | 5577133 |
THE FURNACE GUY HEATING & COOLING | H= | L | 07/25/2017 | Locked at 5:27, need access code. | MICHAELS | MICHAELS | | H= | L | 5575860 |
THE FURNACE GUY HEATING & COOLING | H= | R | 07/24/2017 | Locked, no access. Trip fee waived. | MICHAELS | MICHAELS | | H= | R | 5574325 |
THE FURNACE GUY HEATING & COOLING | H= | P | 07/20/2017 | Undercut bedroom doors without ducted return 1" above finished floor, need to cap clean out tee when installed prior to trap on primary drain. Note: slab on grade, 6" combo air from attic, full a/c, secondary piped to floor drain for structural protection. | MICHAELS | MICHAELS | | H= | P | 5570128 |
THE FURNACE GUY HEATING & COOLING | HC | C | 06/05/2017 | RELEASE METER | MICHAELS | MICHAELS | | HC | C | 5526078 |
THE FURNACE GUY HEATING & COOLING | HRR | C | 06/05/2017 | Corrections made. | MICHAELS | MICHAELS | | HRR | C | 5526067 |
THE FURNACE GUY HEATING & COOLING | HRR | P | 06/02/2017 | Roofing material against b-vent, support dryer vent every 4ft. in attic. Note: slab on grade, 6" osa, 6" combo air from attic, a/c rough(lineset only). | MICHAELS | MICHAELS | | HRR | P | 5524564 |
J.J. BROOME PLUMBING AND HEATING LLC | HI | C | 05/31/2017 | 10# test ok. 1" main to furn, w/h. | MICHAELS | MICHAELS | | HI | C | 5521898 |
J.J. BROOME PLUMBING AND HEATING LLC | P= | C | 07/20/2017 | OK, PVB installed | SHANEN | SHANEN | | P= | C | 5570003 |
J.J. BROOME PLUMBING AND HEATING LLC | PTO | C | 05/30/2017 | slab on grade | TED | TED | | PTO | C | 5519617 |
J.J. BROOME PLUMBING AND HEATING LLC | PB | C | 05/02/2017 | | TAYLOR | TAYLOR | | PB | C | 5492849 |
J.J. BROOME PLUMBING AND HEATING LLC | PB | P | 04/21/2017 | stub in's ok. | TAYLOR | TAYLOR | | PB | P | 5482716 |