ALEXANDHER BUILDING CO, INC. | B= | C | 07/24/2017 | All other required Final inspections are complete. (This is a computer generated result) | NATHAN | NATHAN | | B= | C | 5573777 |
ALEXANDHER BUILDING CO, INC. | B= | P | 07/17/2017 | . Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2), External Agency Inspection Z= by ZONING is not Completed yet (Contact: 719-385-5982). | NATHAN | NATHAN | | B= | P | 5566813 |
ALEXANDHER BUILDING CO, INC. | BFR | C | 07/17/2017 | items corrected | NATHAN | NATHAN | | BFR | C | 5566796 |
ALEXANDHER BUILDING CO, INC. | BSP | R | 06/20/2017 | inspection not needed no new work done | NATHAN | NATHAN | | BSP | R | 5541121 |
ALEXANDHER BUILDING CO, INC. | BSP | P | 06/16/2017 | headwall detail and caulking completed / front and rear door hardware discussed for change of occupancy / marking of rated wall above ceiling required by final. | NATHAN | NATHAN | | BSP | P | 5537694 |
ALEXANDHER BUILDING CO, INC. | BSP | P | 06/09/2017 | final layer of fire wall needs fire caulk installed per depth per HWD / rock wool insulation completed and okay | NATHAN | NATHAN | | BSP | P | 5530871 |
ALEXANDHER BUILDING CO, INC. | BSP | P | 06/06/2017 | 3rd layer or second of new drywall at rated wall okay | NATHAN | NATHAN | | BSP | P | 5527396 |
ALEXANDHER BUILDING CO, INC. | BSP | P | 06/02/2017 | 2ND LAYER DRYWALL OKAY / HEADWALL AND WALL ASSEMBLY ON SITE. | NATHAN | NATHAN | | BSP | P | 5523959 |
ALEXANDHER BUILDING CO, INC. | BSP | P | 05/30/2017 | In progress inspection for 2hr fire wall per new detail GA File NO. WP 7125 / 1st layer throughout OK / Need to inspect 2nd layer once installed / Head wall detail spliced into plans | NICK | NICK | | BSP | P | 5520338 |
ALEXANDHER BUILDING CO, INC. | BSP | T | 05/25/2017 | PAID (REC#1427342) PLAN SPLICE FEE: $50 by: MICHAELA for Construction: Revise rated assembly | MICHAELA | MICHAELA | | BSP | T | 5517592 |
ALEXANDHER BUILDING CO, INC. | BFR | P | 05/12/2017 | with completed required inspections frame of interior non bearing walls okay | NATHAN | NATHAN | | BFR | P | 5505290 |
ALEXANDHER BUILDING CO, INC. | BFR | R | 04/24/2017 | need new fire barrier listing other than U408 framing is 24" oc and have new listing on site by next inspection / need all UL listings for penetrations at fire barrier / need headwall detail for joint connection to roof / patch all holes at upper portion of walls / Reviewed Accessible Elements / verified layers on walls are rated drywall / discussed hardware and signage at doors interior and exterior. | NATHAN | NATHAN | | BFR | R | 5485343 |
EL PASO ELECTRIC, LLC. | E= | C | 07/07/2017 | | BRIAN | BRIAN | | E= | C | 5557450 |
EL PASO ELECTRIC, LLC. | ER | C | 07/07/2017 | CEILING --OK | BRIAN | BRIAN | | ER | C | 5557446 |
EL PASO ELECTRIC, LLC. | ER | P | 05/11/2017 | WALLS --OK | BRIAN | BRIAN | | ER | P | 5503056 |
AIRTECH MECHANICAL, INC. | H= | C | 07/17/2017 | TAB REPORT RECEIVED AND CORRECTION MADE AT FAN | JERRYF | JERRYF | | H= | C | 5566285 |
AIRTECH MECHANICAL, INC. | H= | P | 07/13/2017 | SEAL EXHAUST DUCT AT BACK DRAFT DAMPER - ATTACH PICTURE OF CORRECTION TO NEXT INSPECTION REQUEST - REST OK | JERRYF | JERRYF | | H= | P | 5563203 |
AIRTECH MECHANICAL, INC. | H= | P | 07/11/2017 | RECEIVED TEST AND BALANCE REPORT. | LIDO | LIDO | | H= | P | 5560278 |
AIRTECH MECHANICAL, INC. | HD | C | 05/08/2017 | ABOVE CEILING OK - FOR FINAL NEED ROOF INSPECTION / VERIFY BACK DRAFT DAMPER AND TAB REPORT | JERRYF | JERRYF | | HD | C | 5498968 |
DRUMMOND PLUMBING LLC | P= | C | 07/13/2017 | OK, | SHANEN | SHANEN | | P= | C | 5562926 |
DRUMMOND PLUMBING LLC | PB | C | 06/15/2017 | Test OK, under ground DWV and 1/2" water lines to re-located lavs | SHANEN | SHANEN | | PB | C | 5536564 |
DRUMMOND PLUMBING LLC | PTO | C | 06/15/2017 | OK, CWV on men's room lav, check vent tie - in and support on water piping in ceiling at final | SHANEN | SHANEN | | PTO | C | 5536563 |