K1 ROOFING AND RESTORATION, LLC. | B= | C | 11/20/2017 | All items complete | JEREMYA | JEREMYA | | B= | C | 5690722 |
K1 ROOFING AND RESTORATION, LLC. | B= | P | 10/27/2017 | Temp CO: Extension-pending final ( Expires: 11/26/2017 12:00:00 AM) | RITA | RITA | | B= | P | 5670160 |
K1 ROOFING AND RESTORATION, LLC. | B= | P | 10/27/2017 | Temp CO: Extension-pending final ( Expires: 11/26/2017 12:00:00 AM) | RITA | RITA | | B= | P | 5670159 |
K1 ROOFING AND RESTORATION, LLC. | B= | P | 09/27/2017 | Temp CO: Extension - plumbing final to be called in and test and balance to be provided this week ( Expires: 10/27/2017 12:00:00 AM) | MINDY | MINDY | | B= | P | 5638163 |
K1 ROOFING AND RESTORATION, LLC. | B= | P | 08/31/2017 | Temp CO: pending final ( Expires: 9/30/2017 12:00:00 AM) | RITA | RITA | | B= | P | 5612517 |
K1 ROOFING AND RESTORATION, LLC. | B= | P | 08/31/2017 | Temp CO: pending final ( Expires: 9/30/2017 12:00:00 AM) | RITA | RITA | | B= | P | 5612516 |
K1 ROOFING AND RESTORATION, LLC. | BSP | P | 07/27/2017 | PLAN SPLICE: (No Fee) by: DANM for Construction: Identify existing wall as 1-hr separation and dash in new 4-hr fire barrier | DANM | DANM | | BSP | P | 5578365 |
K1 ROOFING AND RESTORATION, LLC. | BSP | T | 07/27/2017 | PAID (REC#1455586) PLAN SPLICE FEE: $50 by: BPHILLIPS for Construction | BPHILLIPS | BPHILLIPS | | BSP | T | 5577739 |
DENVER COMMERCIAL PLBG., INC. | BSP | P | 07/27/2017 | PLAN SPLICE: (No Fee) by: TCRIPPEN for Plumbing: plumbing splice 7-27-17 | TCRIPPEN | TCRIPPEN | | BSP | P | 5577596 |
K1 ROOFING AND RESTORATION, LLC. | B= | P | 07/05/2017 | Temp CO: partials ( Expires: 8/4/2017 12:00:00 AM) | NELIDA | NELIDA | | B= | P | 5555353 |
K1 ROOFING AND RESTORATION, LLC. | B= | P | 07/05/2017 | Building items complete with exception of spliced drawing showing 1-hr fire barrier in lieu of 3-hr fire barrier // Verified progress on 4-hr fire barrier being built on permit K82556 // Pending all other final inspections complete. Additional Inspections Required (computer generated): DENVER COMMERCIAL PLBG., INC. Mechanical Final Inspection is not Completed yet, DENVER COMMERCIAL PLBG., INC. Plumbing Final Inspection is not Completed yet, DR GREEN PLUMB, LLC Mechanical Final Inspection is not Completed yet. | JEREMYA | JEREMYA | | B= | P | 5554802 |
K1 ROOFING AND RESTORATION, LLC. | B= | R | 07/03/2017 | Need to change plans to show "Existing 1-hr Fire Barrier' IN LIEU OF "Existing 3-hr Fire Wall" // Need to fix holes in 1-hr wall so it is rated for 1-hr // Need to obtain plumbing permit and complete all required inspections // Need to have progress made on 4-hr Fire Barrier that is replacing required 3-hr fire wall for Occ. Separation. Additional Inspections Required (computer generated): DENVER COMMERCIAL PLBG., INC. Mechanical Final Inspection is not Completed yet, DR GREEN PLUMB, LLC Mechanical Final Inspection is not Completed yet. | JEREMYA | JEREMYA | | B= | R | 5553862 |
K1 ROOFING AND RESTORATION, LLC. | BSP | R | 06/29/2017 | Met on-site with Dale, Bert (RBD) and Dave (K1 Sub). Discussed requirements to allow occupancy of the space. Contingent of occupancy, is the 4-hr fire barrier being built on permit K82556. This is also a K1 permit. This wall has not been started. The "existing" 3-hr Fire Barrier on the plans is not correct. Per the tenant buildout to the norths approved plans, this is a 1-hr fire barrier. Will need clarification on approved set for this item. Also on permit K82556, the wall built to separate the north tenant from the fitness area, is to be an "existing" 1-hr fire barrier. The approved plans on this permit show it as a non-rated partition which is correct per the calculations for non-sep use for Crunch and BMC. Will need clarification on the K82556 plans.. Still need to obtain plumbing permit and complete all required inspections. Need to complete all other finals. | JEREMYA | JEREMYA | | BSP | R | 5550641 |
K1 ROOFING AND RESTORATION, LLC. | BSP | R | 06/29/2017 | walked job with Bert and Jeremy / new 4-hour fire barrier has not been started, no progress / went in back of BMC and checked | DALE | DALE | | BSP | R | 5550549 |
K1 ROOFING AND RESTORATION, LLC. | B16 | P | 06/28/2017 | Met with David contractor rep at my desk reviewed transfer showers and how to comply with ANSI standards per Dales comments/Need 4 hour fire barrier installed on permit #82556/NEED PLUMBING CONTRACTOR ATTACHED TO THIS PERMIT | BERTW | BERTW | | B16 | P | 5550132 |
DR GREEN PLUMB, LLC | BSP | P | 06/28/2017 | PLAN SPLICE: (No Fee) by: JUSTINC for Mechanical: Revised to show duct as spiral | JUSTINC | JUSTINC | | BSP | P | 5549901 |
K1 ROOFING AND RESTORATION, LLC. | BSP | P | 06/28/2017 | transfer showers need to be 36"x36" | DALE | DALE | | BSP | P | 5549406 |
DR GREEN PLUMB, LLC | BSP | T | 06/16/2017 | PAID (REC#1432438) PLAN SPLICE FEE: $50 by: DALEH for Mechanical: splice to changes to duct serving rtu 1 | DALEH | DALEH | | BSP | T | 5537817 |
K1 ROOFING AND RESTORATION, LLC. | BSP | R | 06/15/2017 | This is not a mechanical inspection, this is a building request. Need to have mechanical contractor call in for what they are getting inspected. | JEREMYA | JEREMYA | | BSP | R | 5536135 |
K1 ROOFING AND RESTORATION, LLC. | BFR | P | 05/08/2017 | all infill walls ok / complete all other inspections / Reviewed Accessible Elements / | DALE | DALE | | BFR | P | 5499729 |
DOWNTOWN ELECTRIC AND LIGHTING INC | E= | C | 06/29/2017 | | SHELBY | SHELBY | | E= | C | 5550749 |
DOWNTOWN ELECTRIC AND LIGHTING INC | E= | P | 06/28/2017 | STILL NEED GFCI PROTECTION ON DRINKING FOUNTAIN ------STILL NEED COMPLETE PANEL SCH-----NEED GFCI OR BLANK OUTLETS WHERE THE OLD DRINKING FOUNTAINS WERE IN THE LOCKER ROOMS--LABEL THE DISCONNECTS FOR THE TANNING BEDS AND THE TANNING BEDS TO MATCH--- | BRIAN | BRIAN | | E= | P | 5550207 |
DOWNTOWN ELECTRIC AND LIGHTING INC | E= | P | 06/26/2017 | need gfci protection for drinking fountains readily accessible,complete panel schedules,can't use yolk to support recepts in industrial covers on 6 of them,no sheet metal screws for lugs on equipment grounds at tanning beds,complete front entry desk | TIMA | TIMA | | E= | P | 5546254 |
DOWNTOWN ELECTRIC AND LIGHTING INC | ER | P | 06/21/2017 | ceiling in group exercise room | TOMC | TOMC | | ER | P | 5541900 |
DOWNTOWN ELECTRIC AND LIGHTING INC | ER | P | 06/15/2017 | all ceilings except group fitness room | TOMC | TOMC | | ER | P | 5536643 |
DOWNTOWN ELECTRIC AND LIGHTING INC | ESL | P | 05/23/2017 | west side counter area | TOMC | TOMC | | ESL | P | 5514041 |
DOWNTOWN ELECTRIC AND LIGHTING INC | ER | P | 05/12/2017 | walls marked on page E2 in orange | TOMC | TOMC | | ER | P | 5504400 |
DR GREEN PLUMB, LLC | H= | C | 11/17/2017 | RECEIVED TAB REPORT .Changed to complete 11/19/17 | LIDO | LIDO | | H= | C | 5688465 |
DENVER COMMERCIAL PLBG., INC. | H= | C | 08/30/2017 | GAS FLEX SIZE HAS BEEN CORRECTED AND SPLICE ON PERMIT | MARKB | MARKB | | H= | C | 5611371 |
DENVER COMMERCIAL PLBG., INC. | H= | P | 07/05/2017 | Still need plan splice for water heater venting and correct size gas flex to each unit. | MARKB | MARKB | | H= | P | 5554488 |
DENVER COMMERCIAL PLBG., INC. | HI | C | 07/05/2017 | Pressure test OK. Piping per plan | MARKB | MARKB | | HI | C | 5554487 |
DENVER COMMERCIAL PLBG., INC. | HV | P | 07/03/2017 | Will need plan revision showing water heater vents exiting building through sidewall instead of roof. | MARKB | MARKB | | HV | P | 5554153 |
DENVER COMMERCIAL PLBG., INC. | HI | R | 07/03/2017 | New gas piping to 6 water heaters will required a pressure test. Gas flex to each unit are undersized for 199k. (talked to contractor by phone). | MARKB | MARKB | | HI | R | 5554148 |
DR GREEN PLUMB, LLC | HD | P | 07/03/2017 | Final pending Matching Test And Balance - landlord may be replacing RTU'S that will require to be permitted. | MARKB | MARKB | | HD | P | 5554142 |
DR GREEN PLUMB, LLC | H= | P | 06/30/2017 | TEST AND BALANCE REPORT RECEIVED DOES NOT MATCH VENTILATION SCHEDULE AND CFM , MISSING REMOTE SMOKE INDICATORS FOR RTU 3-4-5 | LIDO | LIDO | | H= | P | 5552111 |
DR GREEN PLUMB, LLC | H= | P | 06/23/2017 | Can not accept engineer letter (wrong info and lacks stamp) - contractor will submit a splice showing all supply ducting changing from rectangle to round. Need to verify remote smoke indicators and provide Test And Balance report. | MARKB | MARKB | | H= | P | 5545004 |
DR GREEN PLUMB, LLC | HD | P | 06/21/2017 | ABOVE CEILING DUCT FOR GROUP FITNESS AREA OK FOR SA/RA DUCTING, FLEX AND DIFFUSERS PENDING LETTER FROM ENGINEER ADDRESSING SWITCHING ALL DUCT FROM RECTANGLE TO ROUND. COVER AT OWN RISK. Still need return air transfer in ceiling, remote smoke indicators and Provide Test And Balance report | MARKB | MARKB | | HD | P | 5542786 |
DR GREEN PLUMB, LLC | HD | T | 06/20/2017 | PAID (REC#1433356): NOT READY / 4TH TRIP REQUIRED - CONTRACTOR TO CALL INSPECTION WHEN READY - PLEASE HAVE PRINTED PLAN SPLICE MADE AVAILABLE FOR NEXT INSPECTION UNABLE TO READ COMPUTER GENERATED SPLICE | JERRYF | JERRYF | | HD | T | 5540642 |
DR GREEN PLUMB, LLC | HD | P | 06/19/2017 | ABOVE CEILING IN VESTIBULE OK ONLY - STILL NEED ALL OTHER | JERRYF | JERRYF | | HD | P | 5540036 |
DR GREEN PLUMB, LLC | HD | T | 06/16/2017 | PAID (REC#1432587): NO CALL AHEAD INFO GIVEN - NO ONSITE PERSONNEL NO INFORMATION OF WHAT WAS TO BE INSPECTED - SEVERAL LARGE DUCT FITTINGS AND DUCT MISSING ABOVE GRID CEILING - NOT READY - STOPPED INSPECTION | JERRYF | JERRYF | | HD | T | 5538122 |
DENVER COMMERCIAL PLBG., INC. | P= | C | 11/16/2017 | | JOEL | JOEL | | P= | C | 5687846 |
DENVER COMMERCIAL PLBG., INC. | P= | P | 07/05/2017 | install expansion tank on new water heater piping (rest ok, per plan) | TED | TED | | P= | P | 5554471 |