HACIENDA CONSTRUCTION, INC. | B= | C | 11/13/2017 | All other required Final inspections are complete. (This is a computer generated result) | LONNYS | LONNYS | | B= | C | 5682745 |
HACIENDA CONSTRUCTION, INC. | B= | P | 11/02/2017 | final ok / basement finished except mechanical area/ decks at rear at master bedroom and kitchen walk out. Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | LONNYS | LONNYS | | B= | P | 5674632 |
HACIENDA CONSTRUCTION, INC. | BIN | C | 08/18/2017 | | JUSTINL | JUSTINL | | BIN | C | 5600480 |
HACIENDA CONSTRUCTION, INC. | BFR | C | 08/18/2017 | Correction made | JUSTINL | JUSTINL | | BFR | C | 5600469 |
HACIENDA CONSTRUCTION, INC. | BIN | R | 08/16/2017 | Insulation OK pending completion of frame | JUSTINL | JUSTINL | | BIN | R | 5597706 |
HACIENDA CONSTRUCTION, INC. | BFR | P | 08/16/2017 | 2 2X4 post at south side of stair landing still not isolated / all other framing corrections made | JUSTINL | JUSTINL | | BFR | P | 5597700 |
HACIENDA CONSTRUCTION, INC. | BFR | P | 08/14/2017 | Missing 1 HTS16 at CG at rear of garage / Need to strap both top plates at porch beam in master bedroom / Missing 2nd TBE on 2 of A1 trusses above front door / 5 Steel columns in basement not bearing on pads / 2 2X4 post on South side of landing not bearing on pad / Missing 1 2X12 in header at East side of shop in basement / Floor joist to double LVL over steel beam does not have 3" of bearing on beam / Missing solid blocking at cantilever North side of basement / Floating wall has less than 1.5" float at North wall in basement | JUSTINL | JUSTINL | | BFR | P | 5595424 |
HACIENDA CONSTRUCTION, INC. | BLA | C | 08/02/2017 | Electrical / light fixture boxes need to be extended 1/2" from the exterior wall, hole in exterior wall north side by pipe line and small section below hole that is missing vapor barrier. Please make corrections and recall for inspection. | NOAH | NOAH | | BLA | C | 5583909 |
HACIENDA CONSTRUCTION, INC. | BSP | P | 07/11/2017 | Narrow brace wall OK / Front porch lid and post OK / Rear patio lid and posts OK / Deck piers diameter and depth OK - Water at base of piers need to be removed | JUSTINL | JUSTINL | | BSP | P | 5560570 |
HACIENDA CONSTRUCTION, INC. | BFD | C | 06/09/2017 | Open hole observation received - Bearing pressure verified 4000PSF / Damp proof OK | JUSTINL | JUSTINL | | BFD | C | 5531193 |
HACIENDA CONSTRUCTION, INC. | BFI | C | 06/08/2017 | 2" foam insulation OK | DAKOTAB | DAKOTAB | | BFI | C | 5529412 |
HACIENDA CONSTRUCTION, INC. | BFD | P | 06/08/2017 | Need to damp proof walk out trench foundation wall -- Drain is usable to Southwest and Southeast corner of house | DAKOTAB | DAKOTAB | | BFD | P | 5529411 |
HACIENDA CONSTRUCTION, INC. | BFN | C | 06/08/2017 | Engineer letter for foundation on file -- Eufer noted -- Foundation design received (4000 PSF) | DAKOTAB | DAKOTAB | | BFN | C | 5529405 |
HACIENDA CONSTRUCTION, INC. | BFT | C | 06/08/2017 | Engineer letter for footing recieved -- Soils report received -- Still need open hole | DAKOTAB | DAKOTAB | | BFT | C | 5529397 |
HACIENDA CONSTRUCTION, INC. | BFT | P | 05/10/2017 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFT | P | 5501995 |
HACIENDA CONSTRUCTION, INC. | BFD | P | 05/10/2017 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFD | P | 5501996 |
HACIENDA CONSTRUCTION, INC. | BFN | P | 05/10/2017 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFN | P | 5501994 |
CL SHARPER ELECTRIC | E= | C | 10/25/2017 | | CRAIG | CRAIG | | E= | C | 5667513 |
CL SHARPER ELECTRIC | E= | R | 10/24/2017 | Still no test lights for garage ceiling outlets. You could also leave a ladder on site. Inspector needs to be able to verify GFCI protection for those outlets. Next time trip fee if not 100 % right. | JOSEPH | JOSEPH | | E= | R | 5665578 |
CL SHARPER ELECTRIC | E= | R | 10/23/2017 | seal around front exterior outlets with concrete -------- gfi back outlet by hose bib -------- install test light for garage door outlets ----------- 2 pole 30 amp breaker need to be clip in rear of breaker ---------- ac and hot tub pre wire | CRAIG | CRAIG | | E= | R | 5664524 |
CL SHARPER ELECTRIC | ER | C | 07/26/2017 | 200 ---1 - #6 , 2 - #10 , no mcc , no central vac , finished basement | TOMC | TOMC | | ER | C | 5577063 |
CL SHARPER ELECTRIC | ES | C | 07/26/2017 | Residential Underground: 200-amp 3 Wire service, ok to set meter / | TOMC | TOMC | | ES | C | 5577054 |
CL SHARPER ELECTRIC | EUG | C | 07/26/2017 | 250 urd | TOMC | TOMC | | EUG | C | 5577030 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | C | 10/27/2017 | correction made. note: partial finished basement, high/low combustion air to mechanical room, 6" outside air to return, a/c rough and line set, mantel ok. | PAULO | PAULO | | H= | C | 5670533 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | P | 10/27/2017 | need to complete open gas line to water heater. other corrections made. note: partial finished basement, high/low combustion air to mechanical room, 6" outside air to return, a/c rough and line set, mantel ok. | PAULO | PAULO | | H= | P | 5669018 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | P | 10/26/2017 | need the following-- clearance to combustibles from furnace vent, proper R.A. path to 1 basement bedroom, complete open gas line to water heater. (WHY ARE THERE 2 FURNACE FILTERS INSTALLED?). rest ok. note: partial finished basement, high/low combustion air to mechanical room, 6" outside air to return, a/c rough and line set, mantel ok. | PAULO | PAULO | | H= | P | 5668167 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HC | C | 08/09/2017 | RELEASE METER | PAULO | PAULO | | HC | C | 5592831 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | C | 08/09/2017 | framing clearances and venting ok. note: partial finished basement, 6" outside air to return, a/c rough and line set, duct design. | PAULO | PAULO | | HRR | C | 5591092 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | R | 08/07/2017 | not ready. waived trip fee. need the following-- installation manual to fire place for framing clearances, can not modify (cut) b-vent to fit installation. re inspect fire place and vent. note: finished basement, 6" outside air to return, a/c rough and line set, duct design. | PAULO | PAULO | | HRR | R | 5588354 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | P | 08/03/2017 | fireplace not secured and framing not finished. NOTES: finished basement, AC coil and line set, outside air to return. | ACE | ACE | | HRR | P | 5585449 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | HI | C | 08/01/2017 | 10 LB TEST OK, 1 1/4" MAIN, 1 FURNACE, 1 WATER HEATER, 1 FIREPLACE, 1 BBQ, 1 RANGE | BENH | BENH | | HI | C | 5582131 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | P= | C | 11/01/2017 | correction made | TED | TED | | P= | C | 5673702 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | P= | P | 10/31/2017 | Uncover basement shower drain for test / basement toilet not working, will not shut off (turned water off to toilet) | TED | TED | | P= | P | 5672372 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | P= | P | 10/31/2017 | certificate of potable water in images | TED | TED | | P= | P | 5671682 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | PTO | C | 08/01/2017 | Note:finished basement,mixing valve at master lav,bar sink aav,no irrigation stub,vtr. | CRADE | CRADE | | PTO | C | 5582434 |
HOMEOWNER | PWO | C | 07/21/2017 | ok,from well sleeved under footer.Need certificate of potable water by final. | CRADE | CRADE | | PWO | C | 5572101 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | PB | C | 06/13/2017 | ok,H20 under footer. | CRADE | CRADE | | PB | C | 5533921 |