BOTTIN CONSTRUCTION, INC | B= | C | 02/23/2018 | 3/4 finished basement / upper walk out deck no stairs / middle walk out deck no stairs | LONNYS | LONNYS | | B= | C | 5772977 |
BOTTIN CONSTRUCTION, INC | BLA | C | 11/15/2017 | lath OK / weep screed needs to be a minimum 4" above unfinished grade at rear of home at final | LONNYS | LONNYS | | BLA | C | 5686060 |
BOTTIN CONSTRUCTION, INC | BIN | C | 10/19/2017 | | BOBF | BOBF | | BIN | C | 5661486 |
BOTTIN CONSTRUCTION, INC | BFR | C | 10/19/2017 | | BOBF | BOBF | | BFR | C | 5661485 |
BOTTIN CONSTRUCTION, INC | BFT | C | 10/19/2017 | design on file / 1500# | BOBF | BOBF | | BFT | C | 5661470 |
BOTTIN CONSTRUCTION, INC | BSP | T | 10/18/2017 | PAID (REC#1460178) PLAN SPLICE FEE: $50 by: SHELLEY for Construction: revised openings | SHELLEY | SHELLEY | | BSP | T | 5659179 |
BOTTIN CONSTRUCTION, INC | BFI | C | 10/12/2017 | letter for foundation insulation on file | BOBF | BOBF | | BFI | C | 5653944 |
BOTTIN CONSTRUCTION, INC | BFD | C | 10/12/2017 | letter for drain on file | BOBF | BOBF | | BFD | C | 5653942 |
BOTTIN CONSTRUCTION, INC | BFN | C | 10/12/2017 | letter for steel and eufer on file | BOBF | BOBF | | BFN | C | 5653941 |
BOTTIN CONSTRUCTION, INC | BFT | P | 10/12/2017 | still need foundation design, open hole 1500# and letter for footing on file | BOBF | BOBF | | BFT | P | 5653934 |
BOTTIN CONSTRUCTION, INC | BFR | R | 10/12/2017 | need plans revised and spliced for added window in main level master / deleting door and adding fireplace in great toom and relocating 3 windows in upper level loft / block garage door brackets / missing SDS screws at bearing block at HG07 / okay to insulate | BOBF | BOBF | | BFR | R | 5653924 |
BOTTIN CONSTRUCTION, INC | BSP | P | 09/15/2017 | front porch trusses okay | BOBF | BOBF | | BSP | P | 5627843 |
BOTTIN CONSTRUCTION, INC | BSP | P | 08/14/2017 | upper and lower deck frames with posts okay / need to complete foundation, drain and foundation insulation | BOBF | BOBF | | BSP | P | 5594471 |
BOTTIN CONSTRUCTION, INC | BFI | P | 06/01/2017 | AUTHORIZED INSPECTION BY ENGINEER | RITA | RITA | RITA | BFI | P | 5522663 |
BOTTIN CONSTRUCTION, INC | BFD | P | 06/01/2017 | AUTHORIZED INSPECTION BY ENGINEER | RITA | RITA | RITA | BFD | P | 5522662 |
BOTTIN CONSTRUCTION, INC | BFT | P | 06/01/2017 | AUTHORIZED INSPECTION BY ENGINEER | RITA | RITA | RITA | BFT | P | 5522661 |
BOTTIN CONSTRUCTION, INC | BFN | P | 06/01/2017 | AUTHORIZED INSPECTION BY ENGINEER | RITA | RITA | RITA | BFN | P | 5522660 |
LONGHORN ELECTRIC, INC. | E= | C | 02/16/2018 | both ac' s ok 25 amp / 35 amp ----------- note no lights above both bath tubs | CRAIG | CRAIG | | E= | C | 5768297 |
LONGHORN ELECTRIC, INC. | EUG | C | 09/28/2017 | 4/w 4/0 al with #2 al grd | CRAIG | CRAIG | | EUG | C | 5639809 |
LONGHORN ELECTRIC, INC. | ES | C | 09/28/2017 | Residential Overhead: 200 - amp 3 Wire new service, ok to seal meter / | CRAIG | CRAIG | | ES | C | 5639802 |
LONGHORN ELECTRIC, INC. | ER | C | 09/20/2017 | no mcc 2 - 10/3 2 - 6/3 al 6/3 cu 4/w #2 al to sub panel No Cent Vac / Irreversible UFER connection / Finished Basement / ----------- conduct for floor heat ok | CRAIG | CRAIG | | ER | C | 5631634 |
GENE'S HEATING AND AIR LLC | H= | C | 02/21/2018 | | BILLS | BILLS | | H= | C | 5770120 |
GENE'S HEATING AND AIR LLC | H= | P | 02/20/2018 | INSTALL WATER HEATER VENT TERMINATION PER MANUFACTURERS INSTRUCTIONS ON PG 25, NEED CONDENSATE LOOP ON WATER HEATER PER MANUFACTURERS INSTRUCTIONS ON PAGE 37 FIGURE 43 NOTES: FINISHED BASEMENT, DIRECT VENT FURNACE X 2, OUTSIDE AIR TO RETURN W/ DAMPER X 2, A/C COMPLETE X 2 | BENH | BENH | | H= | P | 5769719 |
GENE'S HEATING AND AIR LLC | HRP | C | 10/19/2017 | | JEFFL | JEFFL | | HRP | C | 5661022 |
GENE'S HEATING AND AIR LLC | HC | C | 10/11/2017 | RELEASE METER | BENH | BENH | | HC | C | 5652530 |
GENE'S HEATING AND AIR LLC | HRR | C | 10/11/2017 | NOTES: CORRECTIONS MADE | BENH | BENH | | HRR | C | 5652528 |
GENE'S HEATING AND AIR LLC | HRR | P | 10/06/2017 | MASTER BEDROOM FIREPLACE LACKS CLEARANCE AT SIDE ON EXTERIOR WALL - BASEMENT FIREPLACE LACKS CLEARANCE FROM VENT TO BOTTOM OF SOFFIT - REST OK NOTES: DUCT DESIGN AND FURNACES OK - AC COIL AND LINE SET X 2 - OSA X 2 - FINISHED BASEMENT | JERRYF | JERRYF | | HRR | P | 5648226 |
O.M.A.G.M., INC. | HI | C | 10/05/2017 | 10 lb test ok, 1 1/2" main, 2x furnaces, 2x water heaters, 4x fireplaces, 1 bbq. | ACE | ACE | | HI | C | 5645676 |
JOLLY PLUMBING & HEATING INC. | P= | C | 02/22/2018 | corrections made | JOSEPHD | JOSEPHD | | P= | C | 5771594 |
JOLLY PLUMBING & HEATING INC. | P= | P | 02/21/2018 | master tub @ main floor crossed, missing aav at upstairs washer box, contractor to verify back flow at upstairs master tub hand spray and all shower hand sprays, need backflow for sprinkler installed, set temp at basement shower & master shower, basement powder room aav needs to be vertical, bathroom up stairs off of green room shower crossed, note: finished basement, potable water certification to scanning, future water softener stubs | JOSEPHD | JOSEPHD | | P= | P | 5770186 |
HOMEOWNER | PWO | C | 10/20/2017 | need certificate of potable water by final, note: yard hydrant backflow protected | TED | TED | | PWO | C | 5662919 |
JOLLY PLUMBING & HEATING INC. | PTO | C | 10/04/2017 | NOTE : FINISHED BASEMENT , AAV AT ALL LAVS , AAV AT WASHER BOX X 2 , RP IN MEC , NO WATER IN , NEED PWO | GABE | GABE | | PTO | C | 5645341 |
JOLLY PLUMBING & HEATING INC. | PB | C | 07/06/2017 | Dwv ok.Basement drains to ejector pit.No water in at this point. | CRADE | CRADE | | PB | C | 5556070 |