PHOENIX FABRICATIONS | B= | C | 12/21/2017 | All other required Final inspections are complete. (This is a computer generated result) | NICK | NICK | | B= | C | 5719795 |
PHOENIX FABRICATIONS | B= | P | 12/20/2017 | . Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet. | NICK | NICK | | B= | P | 5718621 |
HAWES PLUMBING | BSP | P | 12/18/2017 | PLAN SPLICE: (No Fee) by: JUSTINC for Mechanical: Revised water heater venting and O.S.A | JUSTINC | JUSTINC | | BSP | P | 5716105 |
HAWES PLUMBING | BSP | T | 11/27/2017 | PAID (REC#1469011) PLAN SPLICE FEE: $50 by: DALEH for Mechanical: see plan screen for splice description | DALEH | DALEH | | BSP | T | 5694263 |
HAWES PLUMBING | BSP | T | 11/06/2017 | PAID (REC#1465263) PLAN SPLICE FEE: $50 by: DALEH for Mechanical: GAS ONLY | DALEH | DALEH | | BSP | T | 5677936 |
PHOENIX FABRICATIONS | BFR | P | 10/31/2017 | Framing for rated soffit in garage OK per plans / Reviewed requirements to inspect both layers of 5/8 type X / Reviewed requirements for penetrations | NICK | NICK | | BFR | P | 5671940 |
EMPOWERED ELECTRIC & SOLAR, LLC. | BSP | P | 10/30/2017 | PLAN SPLICE: (No Fee) by: SHELBY for Electrical | SHELBY | SHELBY | | BSP | P | 5671441 |
PHOENIX FABRICATIONS | BSP | T | 10/30/2017 | PAID (REC#1462608) PLAN SPLICE FEE: $50 by: MICHAELA for Construction: 1-hr. soffit detail | MICHAELA | MICHAELA | | BSP | T | 5671332 |
PHOENIX FABRICATIONS | BSP | T | 07/31/2017 | PAID (REC#1443052) PLAN SPLICE FEE: $50 by: DALEH for Mechanical: added laundry room | DALEH | DALEH | | BSP | T | 5581016 |
PHOENIX FABRICATIONS | BFR | P | 07/28/2017 | Frame for interior remodel OK / Partition walls not done or penetrated / Need all MEP's complete | NICK | NICK | | BFR | P | 5579062 |
EMPOWERED ELECTRIC & SOLAR, LLC. | E= | C | 11/22/2017 | unit #2, and common areas | JOHNN | JOHNN | | E= | C | 5693219 |
EMPOWERED ELECTRIC & SOLAR, LLC. | E= | P | 11/21/2017 | need to look into which units this permit includes, unit 1,2,house are ok | JOHNN | JOHNN | | E= | P | 5691471 |
EMPOWERED ELECTRIC & SOLAR, LLC. | ES | C | 11/03/2017 | Commercial Service: 200-amp 3 Wire service, ok to set meter for all units, existing commercial, service upgrade, | JOHNN | JOHNN | | ES | C | 5675497 |
EMPOWERED ELECTRIC & SOLAR, LLC. | ES | R | 11/01/2017 | raise service riser above point of attachment, | JOHNN | JOHNN | | ES | R | 5673919 |
EMPOWERED ELECTRIC & SOLAR, LLC. | ES | R | 10/31/2017 | Commercial Service: NEED POINT OF ATTACHMENT TO BE 16' ---NEED BRASS ADDRESS TAGS INSTALLED TO VERIFY WIRE AND BREAKER SIZES---- | BRIAN | BRIAN | | ES | R | 5672410 |
EMPOWERED ELECTRIC & SOLAR, LLC. | ER | P | 08/16/2017 | laundry rm,ok | JOHNN | JOHNN | | ER | P | 5598155 |
HAWES PLUMBING | H= | C | 12/18/2017 | ALL WORK COMPLETE | JON | JON | | H= | C | 5716224 |
HAWES PLUMBING | HV | C | 12/15/2017 | 2- WATER HEATER VENTS. NEED TO SHOW COMBUSTION AIR ON PLANS. | JON | JON | | HV | C | 5714256 |
HAWES PLUMBING | H= | P | 12/11/2017 | EXHAUST HOODS OK FOR ALL 3 APARTMENTS. WALL FURNACE VENT COMPLETE. STILL NEED WATER HEATER VENT INSPECTIONS CALLED, WENT OVER THIS WITH HEATING CONTRACTOR AND PLUMBING CONTRACTOR ON SITE. MANUFACTURE INSTALLATION INSTRUCTIONS TO BE FOLLOWED. MAY HAVE ISSUE WITH PUBLIC SIDE WALK UNDER WATER HEATER VENT TERMINATIONS. CONTRACTOR TO FOLLOW UP WITH INSTRUCTIONS AND COMBUSTION AIR PROVISIONS BEFORE NEXT INSPECTION. STILL NEED TO VERIFY PERMITS FOR APARTMENT NUMBER 1 DOWNSTAIRS AND REVIEW PLANS FOR WATER HEATER LOCATIONS AND COMBUSTION AIR. | JON | JON | | H= | P | 5708852 |
HAWES PLUMBING | H= | R | 12/04/2017 | NEED DUCT INSPECTIONS FOR RANGE HOODS, CALLED CONTRACTOR ABOUT DUCT SEALING. WALL HEATER VENT CONCEALED AND HAS WOOD ENCLOSURE AROUND TOP OF HEATER, NEED INSTRUCTIONS FOR HEATER. | JON | JON | | H= | R | 5702177 |
HAWES PLUMBING | HC | C | 11/14/2017 | RELEASE METER FOR ALL 4 APARTMENTS. | JON | JON | | HC | C | 5685091 |
HAWES PLUMBING | HI | C | 11/14/2017 | APARTMENT 2 GAS AND DIRECT VENT WALL HEATER OK. NEED APARTMENT NUMBER 1 PLANS AND PERMIT OBTAINED. ALSO NEED INSPECTIONS FOR THE 2 COMMON WATER HEATERS FOR ALL 4 APARTMENTS. NEED VENT INSPECTIONS CALLED ALSO. THE OTHER 2 PERMITS FOR K96557 AND K91667 HAVE NO HEATING PERMITS ATTACHED. NEED TO ATTACH PERMITS AND CA;LL INSPECTIONS. | JON | JON | | HI | C | 5685076 |
HAWES PLUMBING | HI | P | 09/28/2017 | 10 LB TEST ONLY. NEW GAS DESIGN NOT FOUND ON PLANS HAS 8 NEW OUTLETS. NEED PLANS TO BE ENGINEERED TO SHOW CSST AND A 14" WATER COLUMN PRESSURE. VERIFIED PRESSURE WITH CSU. CONTRACTOR TO HAVE PRESSURE INCREASE APPROVAL FROM CSU SENTTO RBD OFFICE. RECALL INSPECTION WHEN APPROVED PLANS ARE SPLICED IN ON PLANS. | JON | JON | | HI | P | 5640071 |
G & S WEST PLUMBING, INC. | P= | C | 11/27/2017 | corrections made. | TAYLOR | TAYLOR | | P= | C | 5694722 |
G & S WEST PLUMBING, INC. | P= | P | 11/21/2017 | need hammer arrestors and 1 inch air gaps at dishwashers, need access to aav, re- grade W/H pan drains, add 1 water heater to scope of work, re- support 1 inch pex after meter, rest ok. | TAYLOR | TAYLOR | | P= | P | 5691715 |
G & S WEST PLUMBING, INC. | PTO+ | C | 08/16/2017 | washer ok, aav in wall by final. | TAYLOR | TAYLOR | | PTO+ | C | 5597909 |
G & S WEST PLUMBING, INC. | PTO | C | 07/10/2017 | aav at kitchen and in attic above tub for apartment 3, aav at kitchen for apartment 2, add 1 water heater to scope of work by final, note: still need mechanical and electrical permits attached. | TAYLOR | TAYLOR | | PTO | C | 5559284 |
G & S WEST PLUMBING, INC. | PTO | P | 07/07/2017 | can not horizontal dry vent shower at apartment 2, need 15 inches from center of toilet to edge of tub at apartment 3, note: need mechanical and electrical permits attached, add 2 water heaters to scope of work. | TAYLOR | TAYLOR | | PTO | P | 5557610 |