HANDCRAFTED CONSTRUCTION INC | B= | C | 10/11/2017 | All other required Final inspections are complete. (This is a computer generated result) | JUSTINL | JUSTINL | | B= | C | 5651238 |
HANDCRAFTED CONSTRUCTION INC | BSP | R | 10/11/2017 | plumbing image uploaded with building BSP inspection - need to upload images to plumbing inspection for plumbing inspector to review | BRIANB | BRIANB | | BSP | R | 5651017 |
HANDCRAFTED CONSTRUCTION INC | B= | P | 10/10/2017 | Building final complete pending P= and H= inspections / Spiral stairs at loft measure 9 1/2" riser height with 11" tread depth measured inward from narrow edge 12" // Fireplace was not installed - will need separate permit for fireplace install. Additional Inspections Required (computer generated): Mechanical Final Inspection is not Completed yet, Plumbing Final Inspection is not Completed yet. | JUSTINL | JUSTINL | | B= | P | 5650894 |
HANDCRAFTED CONSTRUCTION INC | B= | T | 10/10/2017 | PAID (REC#1458208) AFTER-HOURS INSPECTION: $200 From: JLANE OK Per BERT | JLANE | JLANE | | B= | T | 5649785 |
HANDCRAFTED CONSTRUCTION INC | BSP | P | 10/10/2017 | letter for porch post connections on file | BRIANB | BRIANB | | BSP | P | 5649733 |
HANDCRAFTED CONSTRUCTION INC | BSP | P | 08/21/2017 | Still need engineer letter for rear porch post connections - Need by final | JUSTINL | JUSTINL | | BSP | P | 5601838 |
HANDCRAFTED CONSTRUCTION INC | BIN | C | 08/21/2017 | | JUSTINL | JUSTINL | | BIN | C | 5601824 |
HANDCRAFTED CONSTRUCTION INC | BFR | C | 08/21/2017 | Still need letter for post connections at rear porch - Need by final / Truss repair detail received - Repair made per detail / Other framing corrections made | JUSTINL | JUSTINL | | BFR | C | 5601819 |
HANDCRAFTED CONSTRUCTION INC | BFT | C | 08/17/2017 | Soils report received | JUSTINL | JUSTINL | | BFT | C | 5599440 |
HANDCRAFTED CONSTRUCTION INC | BFR | P | 08/17/2017 | Missing attic access / Still need engineer letter for rear porch post base connections / Still need engineer detail for truss repair on T02 truss / Engineer letter received for as built condition for great room to breeze way / updated truss detail received / Other framing corrections made// OK to insulate | JUSTINL | JUSTINL | | BFR | P | 5599436 |
HANDCRAFTED CONSTRUCTION INC | BLA | C | 08/17/2017 | | JUSTINL | JUSTINL | | BLA | C | 5599429 |
HANDCRAFTED CONSTRUCTION INC | BFR | R | 08/15/2017 | STILL NEED TO COMPLETE ELECTRICAL ROUGH INSPECTION: Missing HDB2 per note A at breeze way / Tie top of balloon frame walls at master and great room and tie to lower walls / Missing roll blocking at all trusses in master and great room / Need letter for as built condition for great room to breeze way transition / Missing ST12 straps on trimmers at front windows in breeze way / Need engineer letter for truss repair on T02 from web 6 to 8 / Missing VTCR clips on V trusses / Wall under G01 needs to be floated / Rear porch lid covered prior to inspection / can not verify rear porch post base / No stairs to master - Check at final | JUSTINL | JUSTINL | | BFR | R | 5596025 |
HANDCRAFTED CONSTRUCTION INC | BFI | C | 06/27/2017 | 2 " R-10 ridged foam OK | JUSTINL | JUSTINL | | BFI | C | 5548125 |
HANDCRAFTED CONSTRUCTION INC | BFN | C | 06/27/2017 | Engineer observation received for foundation / Open hole received / Foundation design received - Bearing pressure verified | JUSTINL | JUSTINL | | BFN | C | 5548048 |
HANDCRAFTED CONSTRUCTION INC | BFT | P | 06/27/2017 | Engineer observation received for footer / Open hole received / 3000 PSF / Still need soils report | JUSTINL | JUSTINL | | BFT | P | 5548034 |
HANDCRAFTED CONSTRUCTION INC | BSP | P | 06/27/2017 | 3 Piers OK | JUSTINL | JUSTINL | | BSP | P | 5548020 |
HANDCRAFTED CONSTRUCTION INC | BFT | P | 05/25/2017 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFT | P | 5517092 |
HANDCRAFTED CONSTRUCTION INC | BFN | P | 05/25/2017 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFN | P | 5517091 |
PORCH ELECTRIC, INC. | E= | C | 10/06/2017 | | CRAIG | CRAIG | | E= | C | 5647445 |
PORCH ELECTRIC, INC. | E= | C | 10/06/2017 | | CRAIG | CRAIG | | E= | C | 5647444 |
PORCH ELECTRIC, INC. | ES | C | 10/06/2017 | Residential Overhead: 200 - amp 3 Wire new service, ok no action needed | CRAIG | CRAIG | | ES | C | 5647441 |
PORCH ELECTRIC, INC. | ER | C | 08/16/2017 | | CRAIG | CRAIG | | ER | C | 5597483 |
PORCH ELECTRIC, INC. | EP | C | 08/11/2017 | 150 amp 4w sub panel at home is fed from 200 amp main service at utility pole. | JOSEPH | JOSEPH | | EP | C | 5593823 |
PORCH ELECTRIC, INC. | ER | P | 08/11/2017 | TC cable needs to be in raceway when it enters the house. --------------- Confirm outlet spacing in loft along railing---------- Conductors run outside of ceiling under gluelam beam. --------- Notes: UFER is not ir ---------- No vac -------- Slab on grade | JOSEPH | JOSEPH | | ER | P | 5593821 |
PORCH ELECTRIC, INC. | EUG | C | 06/27/2017 | #2 equip grd | TOMC | TOMC | | EUG | C | 5547869 |
PORCH ELECTRIC, INC. | EUG | R | 06/22/2017 | install equipment ground wire ---------- 3/w 4/0 al | CRAIG | CRAIG | | EUG | R | 5544178 |
ARROW HAWK HEATING, LLC | H= | C | 10/11/2017 | REVIEWED PICTURES WITH CONTACTOR | JON | JON | | H= | C | 5651227 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | HWP | C | 10/09/2017 | ok. | PAULO | PAULO | | HWP | C | 5649536 |
ARROW HAWK HEATING, LLC | H= | P | 10/09/2017 | need the following-- complete back flow drain and temp. & press. pipes to proper height. rest ok. note: direct vent boiler radiant heat with storage tank for potable hot water, no a/c. | PAULO | PAULO | | H= | P | 5649534 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | HWP | P | 08/15/2017 | 60# test to upper level radiant heat pipe ok. | PAULO | PAULO | | HWP | P | 5596731 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | HC | C | 08/14/2017 | RELEASE METER | PAULO | PAULO | | HC | C | 5595377 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | HI | C | 08/14/2017 | 10# test ok. note: 1 1/4" main at 80' to boiler, BBQ and future 3/4" stub at wood burning fire place. | PAULO | PAULO | | HI | C | 5595363 |
ARROW HAWK HEATING, LLC | HRR | C | 08/11/2017 | correction made. note: direct vent boiler radiant heat with storage tank for potable hot water, no a/c. | PAULO | PAULO | | HRR | C | 5593869 |
ARROW HAWK HEATING, LLC | HRR | P | 08/10/2017 | need to complete bath fan exhaust duct to bath fan and terminate through roof deck. rest ok. note: direct vent boiler radiant heat with storage tank for potable hot water, no a/c. | PAULO | PAULO | | HRR | P | 5592574 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | HWP | P | 06/27/2017 | 60# test ok on all zones. | ACE | ACE | | HWP | P | 5547671 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | HO | C | 06/22/2017 | 10# test ok. note: 1 1/4" poly at 90' to home, tracer wire installed. | PAULO | PAULO | | HO | C | 5543735 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | P= | C | 10/11/2017 | WATER CERT AND PICTURE FOR BACK FLOW IN WELL PIT RECIEVED | JON | JON | | P= | C | 5651237 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | P= | P | 10/10/2017 | need certificate of potable water, need backflow protection on water line to barn inside hydrant, yard hydrant outside protected | TED | TED | | P= | P | 5650152 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | PTO | C | 08/14/2017 | Note:on slab,vtr. | CRADE | CRADE | | PTO | C | 5595000 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | PB | C | 06/21/2017 | ok,H20 under footer. | CRADE | CRADE | | PB | C | 5542118 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | PWO | C | 06/21/2017 | ok,H20 under footer.Need back flow device on water line to barn and yard hydrant by final.Need certification of potable water by final. | CRADE | CRADE | | PWO | C | 5542108 |