REYNOLDS CONSTRUCTION | B= | C | 08/01/2017 | insignia# 31983 -- serial # 005-00P-A002545AB | SCOTTS | SCOTTS | | B= | C | 5581989 |
REYNOLDS CONSTRUCTION | BTD | C | 07/06/2017 | corrections complete/ X12 instructions on site | SCOTTS | SCOTTS | | BTD | C | 5555901 |
REYNOLDS CONSTRUCTION | BTD | P | 06/30/2017 | Need to complete exterior marriage line connection / need 2 lag bolt s at each end of floor beam/ roof marriage lines ok / interior wall marriage line connections ok / need weight down vapor barrier so it in place for inspector / serial # 005-00P-H-A002545 AB / need manufacture installation instructions for X12 tie downs | ERICR | ERICR | | BTD | P | 5553494 |
REYNOLDS CONSTRUCTION | BFT | C | 06/14/2017 | | SCOTTS | SCOTTS | | BFT | C | 5534614 |
REYNOLDS CONSTRUCTION | BFT | P | 06/12/2017 | pending open hole with correct address -- pour at own risk | SCOTTS | SCOTTS | | BFT | P | 5532151 |
REYNOLDS CONSTRUCTION | BFT | P | 06/09/2017 | all footing except the 36" footing on south end ok / the south 36" footing only 8" needs to be 10"/ need open hole observation with right address | ERICR | ERICR | | BFT | P | 5531505 |
LUMENOCITY ELECTRICAL DESIGN, LLC | E= | C | 07/31/2017 | 200 amp sub panel at manufactured home ok. ----------------- ac is pre roughed. | JOSEPH | JOSEPH | | E= | C | 5580575 |
LUMENOCITY ELECTRICAL DESIGN, LLC | ES | C | 07/31/2017 | Residential Underground: 200 amp 3w new service at utility pole. meter is in need reseal | JOSEPH | JOSEPH | | ES | C | 5580564 |
LUMENOCITY ELECTRICAL DESIGN, LLC | E= | R | 07/28/2017 | Float neutral at 200 amp sub panel at home. ------- Add a ground rod at home. ------- add inter - system bonding terminal. ----------- Notes: AC is pre roughed | JOSEPH | JOSEPH | | E= | R | 5579030 |
LUMENOCITY ELECTRICAL DESIGN, LLC | ES | R | 07/28/2017 | Add a ground rod at the utility pole. ------------ Rest of 200 amp service ok | JOSEPH | JOSEPH | | ES | R | 5579025 |
LUMENOCITY ELECTRICAL DESIGN, LLC | ES | P | 06/22/2017 | Residential Underground: Pre release ok | DEAN | DEAN | | ES | P | 5562760 |
LUMENOCITY ELECTRICAL DESIGN, LLC | EUG | C | 06/08/2017 | 4/w 250 mcm al with #2 al grd from panel on pole to new house | CRAIG | CRAIG | | EUG | C | 5562759 |
FALCON HEATING AND COOLING, INC. | H= | C | 07/25/2017 | Direct vent down flow furnace, Electric water heater , No A/C | PAULO | PAULO | | H= | C | 5575073 |
FALCON HEATING AND COOLING, INC. | HC | C | 07/25/2017 | RELEASE METER | PAULO | PAULO | | HC | C | 5575072 |
FALCON HEATING AND COOLING, INC. | HRR | C | 07/25/2017 | Direct vent down flow furnace, Electric water heater , No A/C | PAULO | PAULO | | HRR | C | 5575056 |
NASRALLAH PLUMBING & HEATING, INC. | HI | C | 06/30/2017 | 10lb test on inside black iron L. P. piping | TED | TED | | HI | C | 5553006 |
NASRALLAH PLUMBING & HEATING, INC. | HO | C | 06/30/2017 | 10lb test on outside under ground L.P. piping from tank to house | TED | TED | | HO | C | 5553002 |
FAIRWAY PLUMBING & HEATING, INC. | P= | C | 08/01/2017 | Certificate of potable water to scanning. | CRADE | CRADE | | P= | C | 5581634 |
FAIRWAY PLUMBING & HEATING, INC. | P= | P | 07/28/2017 | Need certificate of potable water.Rest ok.Note:dwv ok,electric water heater. | CRADE | CRADE | | P= | P | 5578951 |
HOMEOWNER | PWO | C | 06/23/2017 | Note:Water line from new house to existing well pit that is tied into existing house.Need certificate of potable water by final. | CRADE | CRADE | | PWO | C | 5544774 |