PARAMOUNT HOMES COMPANY | B= | C | 11/13/2017 | | NICK | NICK | | B= | C | 5682610 |
PARAMOUNT HOMES COMPANY | BFR | C | 11/07/2017 | Eng letter on file fr ST22 straps / Still need letter of observation since RBD never inspected straps per letter / UPON FURTHER REVIEW LETTER STATES OK FROM ENG AS INSTALLED 11/9/17 | NICK | NICK | | BFR | C | 5678511 |
PARAMOUNT HOMES COMPANY | BFR | R | 09/13/2017 | Could not find letter on site / Need letter to close out frame | NICK | NICK | | BFR | R | 5624470 |
PARAMOUNT HOMES COMPANY | BLA | C | 09/13/2017 | | NICK | NICK | | BLA | C | 5624408 |
PARAMOUNT HOMES COMPANY | BIN | P | 08/30/2017 | Insulation OK pending frame complete | NICK | NICK | | BIN | P | 5611380 |
PARAMOUNT HOMES COMPANY | BFR | P | 08/30/2017 | Still need ST22 strap or Eng letter / All other items OK | NICK | NICK | | BFR | P | 5611309 |
PARAMOUNT HOMES COMPANY | BFR | P | 08/23/2017 | Need to install ST22 strap per detail A or provide letter for change / Need to set post in garage / Need to install double LVL header for garage window / Eng letters on file for changes / Need plumbing complete | NICK | NICK | | BFR | P | 5604286 |
PARAMOUNT HOMES COMPANY | BSP | P | 08/04/2017 | Structural LVL's for facia OK / Front porch frame OK / Need eng letter for wedge anchors used for portal frame, need to complete portal frame and inspect | NICK | NICK | | BSP | P | 5585958 |
PARAMOUNT HOMES COMPANY | BFD | C | 07/17/2017 | Drain is to sump at back of house / Drain OK | NICK | NICK | | BFD | C | 5566211 |
PARAMOUNT HOMES COMPANY | BFN | C | 07/07/2017 | Eng letter of observation on file / Eufer rod observation on file / Foundation design on file | NICK | NICK | | BFN | C | 5556925 |
PARAMOUNT HOMES COMPANY | BFT | C | 07/07/2017 | Eng letter of observation on file | NICK | NICK | | BFT | C | 5556920 |
PARAMOUNT HOMES COMPANY | BFD | P | 06/30/2017 | Need to install daylight section of drain system / All other aspects of drain OK / | NICK | NICK | | BFD | P | 5552176 |
PARAMOUNT HOMES COMPANY | BFI | C | 06/30/2017 | R-10 at 2' OK | NICK | NICK | | BFI | C | 5552175 |
PARAMOUNT HOMES COMPANY | BFN | P | 06/30/2017 | Still need foundation design / Still need Eng letter of observation / Still need eng letter of observation for Eufer rod | NICK | NICK | | BFN | P | 5552169 |
PARAMOUNT HOMES COMPANY | BFT | P | 06/30/2017 | Still need Eng letter of observation | NICK | NICK | | BFT | P | 5552168 |
PARAMOUNT HOMES COMPANY | BSP | P | 06/29/2017 | Open hole and soils on file / #1000psf / Drain usable | NICK | NICK | | BSP | P | 5550422 |
PARAMOUNT HOMES COMPANY | BFT | P | 06/13/2017 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFT | P | 5533990 |
PARAMOUNT HOMES COMPANY | BFN | P | 06/13/2017 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFN | P | 5533989 |
ROWAN ELECTRIC LLC | E= | C | 11/09/2017 | hot tub:ok | JOHNN | JOHNN | | E= | C | 5681658 |
ROWAN ELECTRIC LLC | E= | R | 10/31/2017 | center of meter needs to be between 5'-6', strap pvc at main panel, mech rm: mc to pressure switch, protect from physical damage/ reroute, laundry rm closet: can not have open fixture, up bath rm missing outlet, | JOHNN | JOHNN | | E= | R | 5672520 |
ROWAN ELECTRIC LLC | ES | C | 09/12/2017 | Residential Underground: 200-amp 3 Wire service, ok to set meter, new res | JOHNN | JOHNN | | ES | C | 5622629 |
ROWAN ELECTRIC LLC | ER | C | 08/30/2017 | removed LB above panel, added all in one, | JOHNN | JOHNN | | ER | C | 5611991 |
ROWAN ELECTRIC LLC | EUG | C | 08/30/2017 | | JOHNN | JOHNN | | EUG | C | 5611972 |
ROWAN ELECTRIC LLC | ES | P | 08/21/2017 | Residential Underground: can not release until trench in front of meter is backfilled,200 amp,3w,service ok | JOHNN | JOHNN | | ES | P | 5602599 |
ROWAN ELECTRIC LLC | ER | C | 08/21/2017 | rough,ok, will need access panel above panel for LB,---------------------------200 amp,3#10,#8al,#6cu,rev ufer,no mcc, | JOHNN | JOHNN | | ER | C | 5602473 |
THE FURNACE GUY HEATING & COOLING | H= | C | 10/31/2017 | 350 CFM FAN | DAVIDH | DAVIDH | | H= | C | 5672119 |
THE FURNACE GUY HEATING & COOLING | H= | R | 10/26/2017 | THE KITCHEN HOOD HAS NOT BEEN INSTALLED. INSTALL THE HOOD AND THEN CALL THIS BACK IN. WHAT ARE THE FAN CFMS? | JEFFB | JEFFB | | H= | R | 5668646 |
THE FURNACE GUY HEATING & COOLING | H= | P | 09/28/2017 | KITCHEN EXHAUST NOT YET INSTALLED AND WHAT IS CFM NOTE DIRECT VENT FURN, NO A/C | DAVIDH | DAVIDH | | H= | P | 5639394 |
SPRINGS GAS, INC. | HC | C | 08/22/2017 | OK FOR METER RELEASE | JERRYF | JERRYF | | HC | C | 5603330 |
SPRINGS GAS, INC. | HI | C | 08/22/2017 | PRESSURE TEST OK | JERRYF | JERRYF | | HI | C | 5603249 |
SPRINGS GAS, INC. | HI | R | 08/21/2017 | LOST TEST NOTE 2 F/P, 1 BBQ,C/T,FURN,W/H 1 1/4" LINE | DAVIDH | DAVIDH | | HI | R | 5602114 |
THE FURNACE GUY HEATING & COOLING | HRR | C | 08/21/2017 | DIRECT VENT FURN , NO A/C ROUGH | DAVIDH | DAVIDH | | HRR | C | 5602113 |
ALPHALETE MECHANICAL LLC | P= | C | 11/01/2017 | finished basement, no irrigation. | TAYLOR | TAYLOR | | P= | C | 5673882 |
ALPHALETE MECHANICAL LLC | P= | P | 10/31/2017 | potable water certificate sent to scanning. | TAYLOR | TAYLOR | | P= | P | 5671773 |
ALPHALETE MECHANICAL LLC | P= | R | 10/25/2017 | no water, re- inspect all, note: need potable water certificate. | TAYLOR | TAYLOR | | P= | R | 5666957 |
ALPHALETE MECHANICAL LLC | PTO | C | 08/23/2017 | correction made. | TAYLOR | TAYLOR | | PTO | C | 5604683 |
ALPHALETE MECHANICAL LLC | PTO | P | 08/15/2017 | need freeze protection in garage at shower trap, rest ok, finished basement, aav at basement lav, check water service connections in mech room by final. | TAYLOR | TAYLOR | | PTO | P | 5596431 |
PARAMOUNT HOMES COMPANY | PWO | C | 07/10/2017 | need potable water certificate by final, note: check sleeve through foundation wall by PTO inspection. | TAYLOR | TAYLOR | | PWO | C | 5559140 |
ALPHALETE MECHANICAL LLC | PB | C | 07/07/2017 | need PWO inspection. | TAYLOR | TAYLOR | | PB | C | 5557427 |