HOMEOWNER | B= | C | 10/05/2020 | Handrail height correction photo on file | TRENTP | TRENTP | | B= | C | 6728893 |
HOMEOWNER | B= | P | 10/02/2020 | Handrail height for handrail at basement stairs is to be between 34 and 38 inches, inspector observed handrail height at 31 inches / Unfinished basement, rear deck w/out stairs -- Schedule a new Building Final when above items are complete. | TRENTP | TRENTP | | B= | P | 6728110 |
HOMEOWNER | BE | L | 09/24/2020 | Renewed for No Fee at 9/24/2020 3:24:54 PM PAID 1716009 | JANE | JANE | | BE | L | 6718687 |
HOMEOWNER | BE | L | 08/29/2018 | Renewed at 8/29/2018 10:50:37 AM | BERTW | BERTW | | BE | L | 5949347 |
HOMEOWNER | BIN | C | 11/14/2017 | corrections okay / photos on file | BRIANB | BRIANB | | BIN | C | 5684138 |
HOMEOWNER | BIN | P | 11/13/2017 | missing air barrier at both main floor bath tub exterior walls | BRIANB | BRIANB | | BIN | P | 5682582 |
HOMEOWNER | BFR | C | 11/09/2017 | all frame corrections okay / unfinished basement | BRIANB | BRIANB | | BFR | C | 5681149 |
HOMEOWNER | BSP | T | 11/07/2017 | PAID (REC#1464443) PLAN SPLICE FEE: $50 by: SHELLEY for Construction: Clarified beam bearing for floor in framed wall; removed BC6 from 6x6 columns in 3 locations. | SHELLEY | SHELLEY | | BSP | T | 5679267 |
HOMEOWNER | BFR | P | 11/07/2017 | missing BC6 caps at all 6x6 columns / missing strap at plate break rear bedroom / missing 2 H25s at AE1 truss at master closet / missing single H25 at master bath tub / firestop and clean out B-vent chase / need letter for beam sitting on 3 (2x6) and all beam bearing points in lieu of beam pockets / missing float spikes at min 32" OC below stairs / upon further inspection stamped letter on file for broken truss correction / need to inspect truss corrections | LONNYS | LONNYS | | BFR | P | 5678913 |
HOMEOWNER | BLA | C | 11/02/2017 | lath completed and ok over garage portal wall | LONNYS | LONNYS | | BLA | C | 5674565 |
HOMEOWNER | BLA | R | 10/30/2017 | lath is still incomplete at the garage walls | BRIANB | BRIANB | | BLA | R | 5671590 |
HOMEOWNER | BSP | P | 10/30/2017 | front and rear porch corrections okay / garage portal wall corrections okay / per approved plan splice dated 10/25/17 | BRIANB | BRIANB | | BSP | P | 5671583 |
HOMEOWNER | BSP | T | 10/25/2017 | PAID (REC#1461786) PLAN SPLICE FEE: $50 by: SHELLEY for Construction: revised portal frame and hold-downs at porches | SHELLEY | SHELLEY | | BSP | T | 5667377 |
HOMEOWNER | BLA | R | 10/24/2017 | MSTI 48 Strap to outside of portal walls // Panel splice needs to be within 24" of center // Missing HTS20's both sides of back porch // Missing LSTA16's x 2 left side of front porch, HTS20's Right side of front porch // Missing all STHD 14 hold downs at portal | SHAUN | SHAUN | | BLA | R | 5665353 |
HOMEOWNER | BLA | R | 10/23/2017 | cancelled by the homeowner per email received / no inspection performed | BRIANB | BRIANB | | BLA | R | 5663499 |
HOMEOWNER | BLA | R | 10/20/2017 | front and rear porch lids and the garage portal wall have been covered with lath prior to inspection / need to expose and provide access to inspect the garage portal wall per details on sheet S3 of the approved design and front - rear covered porch lid framing - trusses and all connections | BRIANB | BRIANB | | BLA | R | 5662336 |
HOMEOWNER | BFT | C | 07/24/2017 | | JUSTINL | JUSTINL | | BFT | C | 5573127 |
HOMEOWNER | BFD | C | 07/24/2017 | Open hole received | JUSTINL | JUSTINL | | BFD | C | 5573125 |
HOMEOWNER | BFT | P | 07/21/2017 | Engineer observation for footer on file / Still need open hole paperwork and drain design | JUSTINL | JUSTINL | | BFT | P | 5571320 |
HOMEOWNER | BFN | C | 07/21/2017 | Engineer observation for foundation on file / Foundation design on file - 1500 PSF / Eufer noted | JUSTINL | JUSTINL | | BFN | C | 5571317 |
HOMEOWNER | BFD | P | 07/20/2017 | Still need all foundation paperwork / Drain is habitable to daylight at SW and to sump pit / Damp proofing OK | JUSTINL | JUSTINL | | BFD | P | 5570362 |
HOMEOWNER | BFN | R | 07/20/2017 | No letter attached - Still need all foundation paperwork | JUSTINL | JUSTINL | | BFN | R | 5570359 |
HOMEOWNER | BFT | R | 07/20/2017 | No letter attached - Still need all foundation paperwork | JUSTINL | JUSTINL | | BFT | R | 5570358 |
HOMEOWNER | BFT | P | 07/19/2017 | AUTHORIZED INSPECTION BY ENGINEER | TERRI | TERRI | TERRI | BFT | P | 5569384 |
HOMEOWNER | BFN | P | 07/19/2017 | AUTHORIZED INSPECTION BY ENGINEER | TERRI | TERRI | TERRI | BFN | P | 5569383 |
HOMEOWNER | E= | C | 09/25/2020 | E= OK ----- A/C PRE-WIRE ----- | GREGM | GREGM | | E= | C | 6720480 |
BRASIER ELECTRIC, INC. | ES | C | 10/24/2017 | Residential Underground: 200 amp 3w new res meter in need reseal | JOSEPH | JOSEPH | | ES | C | 5665677 |
BRASIER ELECTRIC, INC. | ER | C | 10/24/2017 | Unfinished basement -------- UFER is not ir -------- 2 - 6/3 cu ------ 10/3 ------ 2 - 14/4 ------ No vac | JOSEPH | JOSEPH | | ER | C | 5665671 |
HOMEOWNER | EUG | C | 07/31/2017 | 4/0 urd | RANDY | RANDY | | EUG | C | 5580933 |
HOMEOWNER | H= | C | 10/01/2020 | CORRECTIONS MADE / NOTE: UNFINISHED BASEMENT, A/C ROUGH COIL AND LINE SET, OUTSIDE AIR TO RETURN DUCT /
| GREGV | GREGV | | H= | C | 6726072 |
HOMEOWNER | H= | P | 09/25/2020 | STILL NEED 2LB LETTER FROM BLACK HILLS ENERGY, NEED GAS RISER AT HOUSE LABELED AS MEDIUM PRESSURE, LABEL NEEDS TO BE YELLOW WITH BLACK WRITING, NOTE: UNFINISHED BASEMENT, A/C ROUGH COIL AND LINE SET, OUTSIDE AIR TO RETURN DUCT / | GREGV | GREGV | | H= | P | 6719508 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | P | 08/30/2018 | NEED 2LB LETTER FROM BLACK HILLS ENERGY, NEED GAS RISER AT HOUSE LABELED AS MEDIUM PRESSURE, LABEL NEEDS TO BE YELLOW WITH BLACK WRITING, NEED RETURN AIR PATHWAY AT ALL BEDROOMS EXCEPT MASTER SUITE, PLUG COIL CONDENSATE DRAIN PORT, BVENT IS MISSING STORM COLLAR AND NEEDS TO BE A MINIMUM OF 12" ABOVE ROOF LINE. NOTE: UNFINISHED BASEMENT, A/C ROUGH COIL AND LINESET, OUTSIDE AIR TO RETURN DUCT | BILLS | BILLS | | H= | P | 5950962 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | R | 03/01/2018 | not ready, no access (locked) to home. (WILL NEED MEDIUM PRESSURE STICKERS ON BOTH ANODELESS RISERS, 2# LETTER FROM GAS PURVEYOR). | PAULO | PAULO | | H= | R | 5777842 |
HOMEOWNER | HO | C | 11/21/2017 | 10LB TEST OK. 122 FEET OF SDR-11 3/4 INCH POLY PIPE WITH TRACER WIRE | BILLS | BILLS | | HO | C | 5692356 |
HOMEOWNER | HC | C | 11/06/2017 | RELEASE METER | PAULO | PAULO | | HC | C | 5677904 |
HOMEOWNER | HRR | C | 11/06/2017 | corrections made. note: unfinished basement, 6" outside air to return, a/c rough and line set, duct design. | PAULO | PAULO | | HRR | C | 5677902 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | P | 11/02/2017 | need the following-- missing S.A. toe kick in kitchen, framing complete around b-vent on main level, complete or plug open gas lines to appliances. rest ok. note: unfinished basement, 6" outside air to return, a/c rough and line set, duct design. | PAULO | PAULO | | HRR | P | 5674899 |
HOMEOWNER | HI | C | 10/13/2017 | 10 LB TEST OK. 1 INCH MAIN,, FURNACE, WATER HEATER,RANGE, AND DRYER.
| JEFFB | JEFFB | | HI | C | 5655422 |
HOMEOWNER | P= | C | 10/01/2020 | Correction made / Note / unfinished basement / No PVB / | GREGV | GREGV | | P= | C | 6726068 |
HOMEOWNER | P= | P | 09/25/2020 | Need hammer arrestor for dishwasher installed / Can not use glue on drains in under sinks in Main bathroom and Master Bathroom, slip joint only / missing escutcheon on shower head main bath / Need to caulk all escutcheons in showers / missing screws in master bath shower valve escutcheon / install T&P to water heater / Note / unfinished basement / No PVB / | GREGV | GREGV | | P= | P | 6719502 |
HOMEOWNER | P= | P | 09/10/2018 | potable water certification sent to scanning | JOSEPHD | JOSEPHD | | P= | P | 5959114 |
HOMEOWNER | P= | P | 08/30/2018 | need potable water certification, need trap guard in laundry room, rest not ready re-inspect all | JOSEPHD | JOSEPHD | | P= | P | 5951120 |
HOMEOWNER | PWO | C | 12/05/2017 | Connection to well head OK, will need potable water certificate by final | SHANEN | SHANEN | | PWO | C | 5702861 |
HOMEOWNER | PTO | C | 11/06/2017 | corrections made | JOSEPHD | JOSEPHD | | PTO | C | 5678000 |
HOMEOWNER | PTO | P | 11/03/2017 | R&R santee on its back at right master lav, re-grade horizontal vent at hall bath, support PEX and PVC per code, water pipe under sized, rest OK, unfinished basement | SHANEN | SHANEN | | PTO | P | 5676381 |
HOMEOWNER | PWO | P | 09/15/2017 | under ground water line only, well has not been drilled at this time, will need to see line connect at well head, will also need certificate of potable water | TED | TED | | PWO | P | 5627496 |