HOMEOWNER | B= | C | 05/09/2018 | All other required Final inspections are complete. (This is a computer generated result) | LONNYS | LONNYS | | B= | C | 5840235 |
HOMEOWNER | B= | P | 02/12/2018 | . Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2), External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: City Engineering Inspections 719-385-5977), External Agency Inspection Z= by ZONING is not Completed yet (Contact: 719-385-5982). | LONNYS | LONNYS | | B= | P | 5763121 |
HOMEOWNER | B= | P | 01/31/2018 | address needs to be posted / finished basement / walkout deck with stairs / deck OK / retaining wall under 48" / deck OK from previous inpsection -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2), External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: City Engineering Inspections 719-385-5977), External Agency Inspection Z= by ZONING is not Completed yet (Contact: 719-385-5982). | LONNYS | LONNYS | | B= | P | 5752712 |
HOMEOWNER | BSP | P | 10/02/2017 | Check deck frame at final for all hardware to be nailed / Retaining wall exceeds 48" from grade to grade at west side of house - check at final - May require retaining wall permit or update foundation design to show retaining wall (UPDATE: upon further review - Since retaining wall is not part of foundation, retaining wall will require separate permit) JL | JUSTINL | JUSTINL | | BSP | P | 5641818 |
HOMEOWNER | BIN | C | 10/02/2017 | ESR report received - spray foam insulation has R-20 Value - Requires ignition barrier - Check for exposed spray foam in un-finished area at final | JUSTINL | JUSTINL | | BIN | C | 5641806 |
HOMEOWNER | BLA | C | 10/02/2017 | Lath OK | JUSTINL | JUSTINL | | BLA | C | 5641803 |
HOMEOWNER | BIN | P | 09/21/2017 | Need ES Report for spray foam used in wall cavities to verify acceptability and R-value / all else OK | RICHB | RICHB | | BIN | P | 5633317 |
HOMEOWNER | BFR | C | 09/15/2017 | Frame & draftstopping OK / plans reviewed electronically - truss calcs onsite | RICHB | RICHB | | BFR | C | 5627583 |
HOMEOWNER | BSP | P | 09/08/2017 | Porch lid sheathing - 7/16" LP FlameBlock nailing OK / plans reviewed electronically | RICHB | RICHB | | BSP | P | 5620326 |
HOMEOWNER | BSP | P | 09/06/2017 | Front porch framing OK / rear deck posts OK / plans reviewed electronically | RICHB | RICHB | | BSP | P | 5617949 |
HOMEOWNER | BSP | T | 08/18/2017 | PAID (REC#1450990) PLAN SPLICE FEE: $50 by: TCRIPPEN for Mechanical: mechanical splice 8-18-17 | TCRIPPEN | TCRIPPEN | | BSP | T | 5599870 |
HOMEOWNER | BSP | P | 08/02/2017 | Piers okay | SHAUN | SHAUN | | BSP | P | 5583156 |
HOMEOWNER | BSP | P | 08/01/2017 | 9 piers back side of house // Scribe inside of pier forms for friction | SHAUN | SHAUN | | BSP | P | 5582306 |
HOMEOWNER | BFI | C | 07/21/2017 | | BERTW | BERTW | | BFI | C | 5571820 |
HOMEOWNER | BFD | C | 07/21/2017 | | BERTW | BERTW | | BFD | C | 5571816 |
HOMEOWNER | BFN | C | 07/21/2017 | | BERTW | BERTW | | BFN | C | 5571813 |
HOMEOWNER | BFT | C | 07/21/2017 | | BERTW | BERTW | | BFT | C | 5571812 |
HOMEOWNER | BFN | R | 07/20/2017 | Need completed footing //Observation report on file date okay // 1,500 psf // Eufer noted | SHAUN | SHAUN | | BFN | R | 5570415 |
HOMEOWNER | BFT | R | 07/20/2017 | Work prior to permit, Call chief John Welton to resolve issue | SHAUN | SHAUN | | BFT | R | 5570414 |
HOMEOWNER | BFI | R | 07/20/2017 | Foundation insulation okay 2" x 24" deep R-10 // Need completed footing | SHAUN | SHAUN | | BFI | R | 5570413 |
HOMEOWNER | BFD | R | 07/20/2017 | Drain usable // Water proofing okay // Drain open to back of house // Need completed footing | SHAUN | SHAUN | | BFD | R | 5570411 |
HOMEOWNER | BFN | P | 07/19/2017 | Ok to use engineer to do inspections with letters of observation and all soils reports to be picked up by inspector @ Drain inspection/RBD will do the drain inspection?Spoke with owner on phone | BERTW | BERTW | | BFN | P | 5568761 |
HOMEOWNER | BFT | P | 07/19/2017 | Ok to use engineer to do inspections with letters of observation and all soils reports to be picked up by inspector @ Drain inspection/RBD will do the drain inspection?Spoke with owner on phone | BERTW | BERTW | | BFT | P | 5568759 |
POSITIVE ELECTRIC, LLC | E= | C | 01/30/2018 | | JOHNN | JOHNN | | E= | C | 5751389 |
POSITIVE ELECTRIC, LLC | E= | R | 01/22/2018 | need access to hood connection, oven disco: connector loose, strap flex or shorten, missing outlet per spacing basement,near under stair closet, rev ufer needs to be accessible, led driver not installed,-------------------------40 amp,a/c,ok | JOHNN | JOHNN | | E= | R | 5743888 |
POSITIVE ELECTRIC, LLC | ES | C | 09/14/2017 | Residential Underground: 200-amp 3 Wire service, ok to set meter, new res, | JOHNN | JOHNN | | ES | C | 5625673 |
POSITIVE ELECTRIC, LLC | ER | C | 09/14/2017 | rough,ok---------------------------100 amp sub panel in basement,rev ufer under panel, | JOHNN | JOHNN | | ER | C | 5625664 |
HOMEOWNER | HSP | C | 05/08/2018 | | BILLS | BILLS | | HSP | C | 5838315 |
THE FURNACE GUY HEATING & COOLING | H= | C | 01/24/2018 | direct vent equip , finished basement, a/c complete | DAVIDH | DAVIDH | | H= | C | 5746856 |
THE FURNACE GUY HEATING & COOLING | HC | C | 09/14/2017 | RELEASE METER | DAVIDH | DAVIDH | | HC | C | 5626144 |
THE FURNACE GUY HEATING & COOLING | HRR | C | 09/14/2017 | BY FINAL NEED BACK DRAFT DAMPER OR MOTORIZED DAMPER IN OSA REST OK NOTE FINISHED BASEMENT DIRECT VENT EQUIP | DAVIDH | DAVIDH | | HRR | C | 5626138 |
CORNERSTONE PLUMBING INC | HI | C | 09/13/2017 | CORRECTIONS MADE NOTE 1 1/4" LINE 1 FURN,W/H,BBQ F/P AND 2 DRYERS | DAVIDH | DAVIDH | | HI | C | 5624576 |
CORNERSTONE PLUMBING INC | HI | R | 09/12/2017 | 10 LB TEST OK BOTH DRYERS NEEDS WALL PLATES AND NAIL PROTECTION INSTALLED . TURN NAIL PLATE FOR BBQ.AND DRYERS REMOVE STRAPPING DOWN WALL TO BOTH DRYERS. | DAVIDH | DAVIDH | | HI | R | 5623601 |
CORNERSTONE PLUMBING INC | P= | C | 01/23/2018 | RP installed, finished basement. | TAYLOR | TAYLOR | | P= | C | 5744941 |
CORNERSTONE PLUMBING INC | P= | P | 01/18/2018 | set tub/ shower temps, need to inspect bar sink and master bath, need drain down at RP. | TAYLOR | TAYLOR | | P= | P | 5741244 |
CORNERSTONE PLUMBING INC | PTO | C | 09/14/2017 | corrections made. | TAYLOR | TAYLOR | | PTO | C | 5625685 |
CORNERSTONE PLUMBING INC | PTO | P | 09/13/2017 | install water lines for basement laundry sink, low test DWV at powder bath, rest ok, finished basement, aav's at powder lav and all sinks in basement ( minus laundry sink ). | TAYLOR | TAYLOR | | PTO | P | 5624363 |
CORNERSTONE PLUMBING INC | PB | C | 08/01/2017 | | TAYLOR | TAYLOR | | PB | C | 5582247 |