HOMEOWNER | B= | C | 04/08/2021 | All other required Final inspections are complete. (This is a computer generated result) | TRENTP | TRENTP | | B= | C | 6926649 |
HOMEOWNER | B= | P | 03/17/2021 | Items corrected per photos on file. Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | TRENTP | TRENTP | | B= | P | 6901065 |
HOMEOWNER | B= | R | 03/08/2021 | Bottom stair for front porch exceeds max riser height of 7 3/4 inches / Missing code compliant address numbers on house, ensure numbers are 5 inches in height and 1/2 inch wide brushstroke / Rear deck w/out stairs, finished basement, no AC. Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | TRENTP | TRENTP | | B= | R | 6891749 |
HOMEOWNER | BE | L | 05/11/2020 | Renewed for $50.00 at 5/11/2020 7:57:12 AM (Receipt#1679315) | KIM | KIM | | BE | L | 6566618 |
HOMEOWNER | BE | C | 04/17/2019 | | JLANE | JLANE | | BE | C | 6168092 |
HOMEOWNER | BIN | C | 10/19/2018 | | LONNYS | LONNYS | | BIN | C | 5999923 |
HOMEOWNER | BFR | C | 10/19/2018 | items corrceted | LONNYS | LONNYS | | BFR | C | 5999922 |
HOMEOWNER | BFR | P | 10/03/2018 | fireblock thru-out / ok to insulate | DALE | DALE | | BFR | P | 5985136 |
HOMEOWNER | BFT | C | 10/03/2018 | Engineers observation Letter received | DALE | DALE | | BFT | C | 5985135 |
HOMEOWNER | BFN | C | 10/03/2018 | Engineers observation Letter received/ Soils report received | DALE | DALE | | BFN | C | 5985128 |
HOMEOWNER | BFD | C | 10/03/2018 | Engineers observation Letter received | DALE | DALE | | BFD | C | 5985127 |
HOMEOWNER | BFI | C | 10/03/2018 | | DALE | DALE | | BFI | C | 5985118 |
HOMEOWNER | BFR | R | 09/27/2018 | complete bft bfn bfd bfi / need straps for narrow braced wall / missing truss lateral, recheck all / no attic access / need anchor bolts within 12" of splices, thru-out / need letter for timbers, stamped / fireblock thru-out | DALE | DALE | | BFR | R | 5979477 |
HOMEOWNER | BSP | P | 01/04/2018 | narrow wall inspection-- missing straps in garage// rest okay | LUKES | LUKES | | BSP | P | 5729521 |
HOMEOWNER | BFD | P | 12/29/2017 | Spoke with homeowner on phone // OK to use engineer to do inspection with reports,open hole,soils report,ufer, and foundation insulation, and drain inspection be addressed in the letter and to be picked up by inspector at next required inspection | MATTHEWM | MATTHEWM | | BFD | P | 5725863 |
HOMEOWNER | BFN | P | 12/29/2017 | Spoke with homeowner on phone // OK to use engineer to do inspection with reports,open hole,soils report,ufer, and foundation insulation, and drain inspection be addressed in the letter and to be picked up by inspector at next required inspection | MATTHEWM | MATTHEWM | | BFN | P | 5725861 |
HOMEOWNER | BFT | P | 12/29/2017 | Spoke with homeowner on phone // OK to use engineer to do inspection with reports,open hole,soils report,ufer, and foundation insulation, and drain inspection be addressed in the letter and to be picked up by inspector at next required inspection | MATTHEWM | MATTHEWM | | BFT | P | 5725860 |
HOMEOWNER | E= | C | 05/13/2020 | | TOMC | TOMC | | E= | C | 6570692 |
HOMEOWNER | ES | C | 09/27/2018 | Residential Underground: 200-amp 3 Wire service, ok to set meter / | TOMC | TOMC | | ES | C | 5978057 |
HOMEOWNER | ER | C | 09/24/2018 | | TOMC | TOMC | | ER | C | 5974343 |
HOMEOWNER | ER | R | 09/21/2018 | add receptacles in kitchen , living room , both lower bedrooms Discussed AFCI/GFCI/TR requirements with owner. / | TOMC | TOMC | | ER | R | 5973559 |
HOMEOWNER | EUG | C | 12/15/2017 | from pole to home 40al service conductors-------- per homeowner panel on pole will be removed and straight to meter | MATTHEW | MATTHEW | | EUG | C | 5714748 |
HOMEOWNER | H= | C | 03/02/2021 | MEDIUM PRESSURE GAS APPROVED FOR THIS ADDRESS, SEE ALERTS. | NANCY | NANCY | | H= | C | 6885451 |
HOMEOWNER | H= | P | 02/26/2021 | NEED LETTER FROM BLACK HILLS APPROVING MEDIUM PRESSURE GAS FOR THIS ADDRESS. | NANCY | NANCY | | H= | P | 6882738 |
HOMEOWNER | H= | P | 02/16/2021 | SEAL FURNACE TO FILTER BOX ALL SIDES / NEED TO SEE MANTLE INSTALLED TO VERIFY CLEARANCES / NEED 2 LB LETTER FROM BLACK HILLS UPLOADED TO PERMIT / NOTE / FINISHED BASEMENT / OUTSIDE AIR WITH DAMPER TO FURNACE RETURN / DIRECT VENT FURNACE / NO A/C / | GREGV | GREGV | | H= | P | 6870927 |
HOMEOWNER | HC | C | 09/07/2018 | RELEASE METER | BILLS | BILLS | | HC | C | 5958262 |
HOMEOWNER | HRR | C | 09/07/2018 | BY FINAL: CONFIRM 2LB LETTER FROM BLACK HILLS ENERGY NOTE: FINISHED BASEMENT, DIRECT VENT FURNACE, NO A/C, OUTSIDE AIR TO RETURN DUCT | BILLS | BILLS | | HRR | C | 5958246 |
HOMEOWNER | HRR | P | 09/06/2018 | DUCT DESIGN DOES NOT MATCH WHAT IS ON FILE. HOMEOWNER SAID HE HAD A NEW ONE SPLICED YESTERDAY BUT I DID NOT SEE IT. WILL CHECK WITH PLAN REVIEW IN MORNING. THE FOLLOWING CORRECTIONS NEED TO BE MADE: THERE ARE 4 SUPPLY CONNECTIONS IN THE BASEMENT THAT NEED MECHANICAL FASTENERS, THE DRYER VENT NEEDS NAIL PROTECTION IN 4 PLACES. THE GAS STUB IN THE DINING AREA IS STUBBED FOR A FUTURE FIREPLACE. THE HOME OWNER WILL PULL SEPARATE PERMIT FOR THAT AT THAT TIME. | KYLEW | KYLEW | | HRR | P | 5957544 |
HOMEOWNER | HRR | R | 04/17/2018 | Multiple ducts undersized. Mechanically fasten and seal all ducts in basement. Install 3rd fireplace. Frame around b-vents and above fireplace on upper level. Install all exhaust fans and vents. Install dryer vent. Stopped inspection. Re-inspect all. | DUSTINS | DUSTINS | | HRR | R | 5818685 |
HOMEOWNER | HO | C | 03/22/2018 | 60# test ok. note: 1 1/4" blk to poly at 260' to home, tracer wire installed with poly pipe. | PAULO | PAULO | | HO | C | 5796937 |
HOMEOWNER | HI | C | 03/22/2018 | NEED TO VERIFY AT FINAL FOR A 2# SYSTEM. 10# test ok. note: 1 1/4" main at 70' to 1- furnace, 1- water heater, 1- cook top, 3- fire places and 1- BBQ. | PAULO | PAULO | | HI | C | 5796673 |
HOMEOWNER | HO | P | 03/13/2018 | completion pending approval of listed tape to underground piping (CONTRACTOR TO VERIFY AND SHOW LISTED AND APPROVED (INSTALLATIONS) WRAP FOR PROTECTION TO CONNECTIONS FOR UNDERGROUND PIPE CONNECTIONS). 60# test ok. note: 1 1/4" blk to poly at 260' to home, tracer wire installed with poly pipe. | PAULO | PAULO | | HO | P | 5787583 |
HOMEOWNER | P= | C | 02/04/2021 | Potable water certificate received | MALYNDA | MALYNDA | | P= | C | 6859488 |
HOMEOWNER | P= | P | 12/03/2020 | Still need potable water certificate, rest ok, images viewed | MALYNDA | MALYNDA | | P= | P | 6795116 |
HOMEOWNER | P= | P | 11/02/2020 | Cannot use accordian fitting under kitchen sink, need 3 hammer arrestors (dishwasher and washer box), need potable water certificate, rest ok Note: pvb installed | MALYNDA | MALYNDA | | P= | P | 6761059 |
HOMEOWNER | PE | C | 10/14/2019 | Last courtesy extension. Future extensions will be $50 each. | NELIDA | NELIDA | | PE | C | 6366783 |
HOMEOWNER | PTO | C | 09/04/2018 | corrections made | JOSEPHD | JOSEPHD | | PTO | C | 5954320 |
HOMEOWNER | PTO | P | 07/20/2018 | need to test water pipe, need to anchor both basement floor flanges, need to use proper transition at hdpe pipe at well tank,(can check that at final), rest ok note: finished basement(2 baths finished), irrigation stub, test caps on roof | JOSEPHD | JOSEPHD | | PTO | P | 5909497 |
HOMEOWNER | PWO | C | 12/06/2017 | need potable water certification by final | JOSEPHD | JOSEPHD | | PWO | C | 5705011 |
HOMEOWNER | PB | C | 09/12/2017 | Note:washer box stack tied into 3" under slab.No water in at this point. | CRADE | CRADE | | PB | C | 5623439 |
HOMEOWNER | PB | P | 09/11/2017 | Need to tie in washer box stack to 3" and re test. | CRADE | CRADE | | PB | P | 5621895 |
HOMEOWNER | XMS | T | 09/05/2018 | PAID (REC#1534183) PLAN SPLICE FEE: $50 by: JUSTINC for Mechanical: Revised duct design and heatloss calculations for as-built conditions | JUSTINC | JUSTINC | | XMS | T | 5955202 |