HL CUSTOM HOMES, LLC | B= | C | 01/25/2018 | | NATHAN | NATHAN | | B= | C | 5747304 |
HL CUSTOM HOMES, LLC | B= | R | 01/04/2018 | need frame completed, CO detectors needed per code, last rise at bottom of stairs over 7 3/4", need address posted on home, need permit for front porch landing/deck attached to house. | NATHAN | NATHAN | | B= | R | 5728947 |
HL CUSTOM HOMES, LLC | BFR | P | 11/01/2017 | need beam splice plate and weld, engineer letter uploaded for floor frame. | NATHAN | NATHAN | | BFR | P | 5672996 |
HL CUSTOM HOMES, LLC | BIN | C | 11/01/2017 | rim corrected | NATHAN | NATHAN | | BIN | C | 5672895 |
HL CUSTOM HOMES, LLC | BIN | R | 10/31/2017 | Need rim insulated at floor. Need frame items completed. Training with Parker. | NATHAN | NATHAN | | BIN | R | 5672623 |
HL CUSTOM HOMES, LLC | BFR | P | 10/26/2017 | need letter for floor, beam splice and post, add shims to header over entry door, okay to insulate | NATHAN | NATHAN | | BFR | P | 5667818 |
HL CUSTOM HOMES, LLC | BFR | R | 10/25/2017 | need engineer letter for floor joists all new, nail all floor joist hangers, support rim at west side foundation, remove float blocks, need bearing over entry door, missing attic access. | NATHAN | NATHAN | | BFR | R | 5666749 |
HL CUSTOM HOMES, LLC | BFR | R | 10/24/2017 | doors are locked and no one present with call ahead. | NATHAN | NATHAN | | BFR | R | 5664824 |
HL CUSTOM HOMES, LLC | BSP | T | 10/23/2017 | PAID (REC#1461154) ADDITIONAL PLAN REVIEW TIME: $50 From: BPHILLIPS Provided engineering for structural modifications. | BPHILLIPS | BPHILLIPS | | BSP | T | 5664103 |
BEE ELECTRIC LLC | E= | C | 12/05/2017 | | BRET | BRET | | E= | C | 5704383 |
BEE ELECTRIC LLC | E= | R | 12/01/2017 | open box next to furnace, open lamp closet under stairs, add strap to mast, use lag bolts not deck screws to strap mast, secure gec to ground rods to structure- tripping hazard | BRET | BRET | | E= | R | 5699907 |
BEE ELECTRIC LLC | ES | C | 11/16/2017 | Residential Overhead: 100 amp 3/w ---- needs connections at the mast and the meter has been painted over | CRAIGS | CRAIGS | | ES | C | 5687011 |
BEE ELECTRIC LLC | ES | R | 11/15/2017 | Residential Overhead: myers hub not service rated --- need #4 from nipple bond bushing to the ground bar -- send pictures --- 100 amp 3/w | CRAIGS | CRAIGS | | ES | R | 5685822 |
BEE ELECTRIC LLC | ER | C | 10/18/2017 | corrections made | GARYL | GARYL | | ER | C | 5658925 |
BEE ELECTRIC LLC | ER | R | 10/17/2017 | install range box for range and dryer, add smoke c/o outside bedroom, add 2 receptacle on 13 foot wall space at stairwell to basement. | BRET | BRET | | ER | R | 5657432 |
BEE ELECTRIC LLC | ER | R | 10/16/2017 | COMPLETE re-inspection, should be a trip fee! 1) need notch plates, 2) broken nm in 2 places, 3)flat nm stapled on edge in several areas, 4) grounds not tied down in several boxes | GARYL | GARYL | | ER | R | 5656128 |
ROCKY MOUNTAIN CLIMATE INC. | H= | C | 01/03/2018 | CORRECT SIZE GRILLES INSTALLED | BILLS | BILLS | | H= | C | 5727534 |
ROCKY MOUNTAIN CLIMATE INC. | H= | P | 01/02/2018 | HIGH / LOW GRILLES ARE NOT LARGE ENOUGH FOR 100000 TOTAL BTU LOAD - REST OK | JERRYF | JERRYF | | H= | P | 5726514 |
ROCKY MOUNTAIN CLIMATE INC. | HC | C | 11/06/2017 | RELEASE METER | JEFFB | JEFFB | | HC | C | 5677074 |
ROCKY MOUNTAIN CLIMATE INC. | HI | C | 11/06/2017 | 10 LB TEST IS OK. | JEFFB | JEFFB | | HI | C | 5677071 |
ROCKY MOUNTAIN CLIMATE INC. | HRR | C | 10/27/2017 | EXHAUST FANS OK, VENT CHASE OK, | BILLS | BILLS | | HRR | C | 5669069 |
ROCKY MOUNTAIN CLIMATE INC. | HI | P | 10/10/2017 | LOW TEST . NOTES: 1" MAIN, 1- FURNACE, 1- WATER HEATER. | LIDO | LIDO | | HI | P | 5649948 |
ROCKY MOUNTAIN CLIMATE INC. | HRR | P | 10/10/2017 | MISSING THE EXHAUST FAN AND EXHAUST VENT IN THE UPSTAIRS BATHROOM AND BASEMENT BATHROOM, WIRE IS TOUCHING B-VENT MAIN LEVEL AND CHASE IS NOT FRAMED OUT FOR B-VENT , BASEMENT FLOOR PLAN IS NOT PER SKETCH I WILL NOTIFY BUILDING. ( ADDED TO NOTES 10/1/17 DO NOT NEED HEAT CALCS ) . NOTES : FINISHED BASEMENT, 6" OUTSIDE AIR TO R/A. | LIDO | LIDO | | HRR | P | 5649947 |
DMB PLUMBING SERVICES INC. | P= | C | 01/04/2018 | no irrigation | JOHNS | JOHNS | | P= | C | 5728361 |
DMB PLUMBING SERVICES INC. | PTO | C | 10/02/2017 | GC NEEDS TO ATTACH ELEC AND MECH PERMITS, rest ok. note: vtr (3), aav @ washer box in wall above with louvered panel @ final, finished bsmnt, no irrigation stub, NEED TO CHECK WATER HEATER, EXPANSION DEVICE, AND EJECTOR PIT FINAL CONNECTIONS @ FINAL | JOHNS | JOHNS | | PTO | C | 5641692 |
DMB PLUMBING SERVICES INC. | PB | C | 09/12/2017 | ok. bsmnt base into ejector pit, water sleeved through foundation | JOHNS | JOHNS | | PB | C | 5622690 |