GOEBEL CONSTRUCTION, INC | B= | C | 01/19/2018 | | SHAUN | SHAUN | | B= | C | 5743253 |
GOEBEL CONSTRUCTION, INC | BLA | C | 11/30/2017 | Weep screed to be a minimum of 4" above ground can check at final | SHAUN | SHAUN | | BLA | C | 5698504 |
GOEBEL CONSTRUCTION, INC | BIN | C | 11/27/2017 | | BRIANB | BRIANB | | BIN | C | 5694804 |
GOEBEL CONSTRUCTION, INC | BFR | C | 11/27/2017 | corrections okay / partial finished basement / no deck | BRIANB | BRIANB | | BFR | C | 5694800 |
GOEBEL CONSTRUCTION, INC | BFR | P | 11/21/2017 | portal wall header needs sheathing nailed off / portal header missing straps / nail off strap at top plate break rear of garage common wall / missing 2nd TBE6 at T2 truss over front door / remove float blocks / OK to insulate | LONNYS | LONNYS | | BFR | P | 5692361 |
GOEBEL CONSTRUCTION, INC | BSP | P | 10/30/2017 | front porch lid and post okay | BRIANB | BRIANB | | BSP | P | 5671555 |
GOEBEL CONSTRUCTION, INC | BFD | C | 10/05/2017 | gravity out fall okay | SHAUN | SHAUN | | BFD | C | 5646302 |
GOEBEL CONSTRUCTION, INC | BFD | P | 10/03/2017 | Drain around habitable // Drain not tied in or gravity out fall | SHAUN | SHAUN | | BFD | P | 5644108 |
GOEBEL CONSTRUCTION, INC | BFN | C | 10/03/2017 | All paperwork on file- Soils open hole 2,000 psf // Drain design habitable // Foundation and footing observation // Eufer noted // Foundation design | SHAUN | SHAUN | | BFN | C | 5644107 |
GOEBEL CONSTRUCTION, INC | BFT | C | 10/03/2017 | All paperwork on file- Soils open hole 2,000 psf // Drain design habitable // Foundation and footing observation // Eufer noted // Foundation design | SHAUN | SHAUN | | BFT | C | 5644106 |
GOEBEL CONSTRUCTION, INC | BFT | P | 09/08/2017 | AUTHORIZED INSPECTION BY ENGINEER | NELIDA | NELIDA | NELIDA | BFT | P | 5620116 |
GOEBEL CONSTRUCTION, INC | BFN | P | 09/08/2017 | AUTHORIZED INSPECTION BY ENGINEER | NELIDA | NELIDA | NELIDA | BFN | P | 5620115 |
A N' M ELECTRIC | E= | C | 01/18/2018 | | CRAIG | CRAIG | | E= | C | 5741936 |
A N' M ELECTRIC | E= | R | 01/05/2018 | circuit 15 needs to be a combo afci, install connector back of 2 gang bell box at front of house-------- no a/c | MATTHEW | MATTHEW | | E= | R | 5730585 |
A N' M ELECTRIC | ES | C | 11/17/2017 | Residential Overhead: 200 amp 3w new res meter is in need reseal | JOSEPH | JOSEPH | | ES | C | 5689685 |
A N' M ELECTRIC | ER | C | 11/17/2017 | Finished basement --------- 10/3 ------- 6/3 cu ---------- UFER is not ir --------- No vac | JOSEPH | JOSEPH | | ER | C | 5689457 |
A N' M ELECTRIC | EUG | C | 11/01/2017 | 3/w 4/0 al | CRAIG | CRAIG | | EUG | C | 5673877 |
MICK HEATING & SHEET METAL CO. | H= | C | 01/08/2018 | ALTERED NOTES ON 1/18/18 HEAT FINAL OK. REST OK 550 CFM HOOD IN KITCHEN, 6'' OSA TO RETURN, HI AND LOW GRILLS TO MECH ROOM | RICKR | RICKR | | H= | C | 5731957 |
MICK HEATING & SHEET METAL CO. | H= | P | 01/03/2018 | need the following-- combustion air to mechanical room, damper to range hood exhaust duct termination, support to water heater vent. 2# letter from gas purveyor for elevated pressure. (what are the cfm's to the range hood?). rest ok. note: finished basement, 6" outside air to return, direct vent furnace, a/c rough only- no line set, no mantel. | PAULO | PAULO | | H= | P | 5727799 |
MICK HEATING & SHEET METAL CO. | HC | C | 11/20/2017 | RELEASE METER | PAULO | PAULO | | HC | C | 5690698 |
MICK HEATING & SHEET METAL CO. | HRR | C | 11/20/2017 | corrections made. note: finished basement, 6" outside air to return, direct vent furnace, a/c rough and line set, duct design. | PAULO | PAULO | | HRR | C | 5690693 |
MICK HEATING & SHEET METAL CO. | HRR | P | 11/17/2017 | need the following-- R.A. at entry per plans, seal 4" and 6" S.A. joints above soffit, undersized S.A. to office. rest ok. note: finished basement, 6" outside air to return, direct vent furnace, a/c rough and line set, duct design. | PAULO | PAULO | | HRR | P | 5688765 |
DAVIS GAS SHOP INC | HI | C | 11/14/2017 | NEEDED BY COMPLETION OF HRR INSPECTION-- INSTALL REGULATOR ON MANIFOLD. NEEDED BY FINAL-- 2# LETTER FROM GAS PURVEYOR. note: 10# test ok. #25 csst at 70' to manifold on medium pressure. 3/4" manifold at 40' to 1- furnace, 1- water heater and 1- fire place. | PAULO | PAULO | | HI | C | 5685206 |
PACIFIC PLUMBING, INCORPORATED | P= | C | 01/17/2018 | note: finished basement, potable water certification to scanning | JOSEPHD | JOSEPHD | | P= | C | 5740001 |
PACIFIC PLUMBING, INCORPORATED | PTO | C | 11/14/2017 | note: finished basement, cwv RH master lav, LH vtr, vtr (4) | JOSEPHD | JOSEPHD | | PTO | C | 5684774 |
HOMEOWNER | PWO | C | 10/18/2017 | need certificate of potable water by final | TED | TED | | PWO | C | 5659826 |
PACIFIC PLUMBING, INCORPORATED | PB | C | 10/12/2017 | corrections made | JOSEPHD | JOSEPHD | | PB | C | 5653247 |
PACIFIC PLUMBING, INCORPORATED | PB | R | 10/11/2017 | low test DWV, no water in at this time | JOSEPHD | JOSEPHD | | PB | R | 5651690 |