HERNANDEZ CONSTRUCTION SERVICES, INC. | B= | C | 02/23/2018 | All other required Final inspections are complete. (This is a computer generated result) | RICHB | RICHB | | B= | C | 5773153 | HERNANDEZ CONSTRUCTION SERVICES, INC. | B= | P | 02/06/2018 | B= requested by accident - should have been H= (met with Contractor) - building inspections not required for this scope of work. Additional Inspections Required (computer generated): CHILLER SYSTEM SERVICE, INC. Mechanical Final Inspection is not Completed yet. | RICHB | RICHB | | B= | P | 5758080 | ELI'S ELECTRICAL LLC | E= | C | 12/28/2017 | BLDG - 2109 units A - M ( skip I ) 15 amp a/c units BLDG - 2111 units A - M ( skip I ) 15 amp a/c units BLDG - 2113 units A - M ( skip I ) 15 amp a/c units | TOMC | TOMC | | E= | C | 5724033 | CHILLER SYSTEM SERVICE, INC. | H= | C | 02/23/2018 | 2109 - UNIT: D - INSTALL COMPLETE 2111 - UNIT: B - INSTALL COMPLETE | MARKB | MARKB | | H= | C | 5773152 | CHILLER SYSTEM SERVICE, INC. | H= | P | 02/22/2018 | 2109 - UNITS: D - STILL NEED CORRECTION. B - INSTALL COMPLETE. 2111 - UNITS: B - STILL NEED CORRECTION. A,G,D - INSTALL COMPLETE 2113 - UNITS: A,D,G,M - INSTALL COMPLETE. | MARKB | MARKB | | H= | P | 5771210 | CHILLER SYSTEM SERVICE, INC. | H= | P | 02/14/2018 | 2109 - UNITS: D, B, - NO INSPECTION. A - INSTALL COMPLETE 2111 - UNITS: A, B, G - NO INSPECTION. D - STILL NEED CORRECTIONS. J - INSTALL COMPLETE 2113 - UNITS: A - ADDRESS FURNACE VENT. G - ADDRESS CONDENSATE. D, M - NO INSPECTION. K - INSTALL COMPLETE | MARKB | MARKB | | H= | P | 5765363 | CHILLER SYSTEM SERVICE, INC. | H= | P | 02/09/2018 | 2113 - UNITS: D - ADDRESS FURNACE VENT. M - LACKS PROPER DUCT TRANSITION. A, G, K - NO ACCESS. B, C, E, F, H, J, L - INSTALL COMPLETE. | MARKB | MARKB | | H= | P | 5762119 | CHILLER SYSTEM SERVICE, INC. | H= | P | 02/08/2018 | 2109 - UNITS: D - ADDRESS FURNACE VENT. A, B - STILL NEED CORRECTIONS. M - INSTALL COMPLETE. 2111 - UNITS: A, B, D, G, J - STILL NEED CORRECTIONS. E, F, K, L, M - INSTALL COMPLETE. | MARKB | MARKB | | H= | P | 5760646 | CHILLER SYSTEM SERVICE, INC. | H= | P | 02/07/2018 | ROOF - PERMANENTLY LABEL CONDENSERS FOR UNITS SERVED. 2109 - UNITS: A, B, D,M - STILL NEED CORRECTIONS. G, H - INSTALL COMPLETE. 2111 - UNITS: A, B, D, E, F, G, J, K, L, M - STILL NEED CORRECTIONS. C, H - INSTALL COMPLETE.
| MARKB | MARKB | | H= | P | 5759431 | CHILLER SYSTEM SERVICE, INC. | H= | P | 02/02/2018 | 2109 - UNITS: A, B, M - ADDRESS FURNACE VENT. D - NO ACCESS. G - FINISH LINESET INSULATION. H - FIRE CAULK STAT WIRE HOLE. C, E, F, J, K, L - INSTALL COMPLETE | MARKB | MARKB | | H= | P | 5755803 | CHILLER SYSTEM SERVICE, INC. | H= | P | 01/26/2018 | 2111: UNITS: A, B, D, G, H, J, L - ADDRESS FURNACE VENT AND LIFT WATER HEATER UP ON APPROVED MATERIALS FOR CONDENSATE. C - NEED PROPER DUCT TRANSITION TO COIL AND LIFT WATER HEATER FOR CONDENSATE. E, F, K, M - LIFT UP WATER HEATER FOR CONDENSATE. ---NO ROOF INSPECTION AT THIS TIME--- ---STILL NEED INSPECTIONS ON 2109 & 2113--- | MARKB | MARKB | | H= | P | 5748830 | CHILLER SYSTEM SERVICE, INC. | HSP | R | 12/06/2017 | ONLY LOOKED AT UNIT #L - NEED TO CONSULT WITH CHIEF INSPECTOR ABOUT HOW A/C IS INSTALLED IN BUILDING, Note Added 12/7/17: After discussion with Chief mechanical inspector, plans will need to be brought back into the building department and reviewed by construction plan review for penetrations through rated assemblies. | MARKB | MARKB | | HSP | R | 5705331 |
|
|