ASPEN VIEW HOMES, LLC | B= | C | 02/22/2018 | Correction complete | JUSTINL | JUSTINL | | B= | C | 5771736 |
ASPEN VIEW HOMES, LLC | B= | R | 02/20/2018 | Missing tempered glass at at master bath tub // Unfinished basement / Rear deck / AC | JUSTINL | JUSTINL | | B= | R | 5769540 |
ASPEN VIEW HOMES, LLC | BIN | C | 01/08/2018 | | DALE | DALE | | BIN | C | 5731381 |
ASPEN VIEW HOMES, LLC | BFR | C | 01/08/2018 | | DALE | DALE | | BFR | C | 5731375 |
ASPEN VIEW HOMES, LLC | BIN | R | 01/04/2018 | canceled by contractor | DALE | DALE | | BIN | R | 5729013 |
ASPEN VIEW HOMES, LLC | BFR | P | 01/04/2018 | canceled by contractor | DALE | DALE | | BFR | P | 5729012 |
ASPEN VIEW HOMES, LLC | BFR | P | 01/02/2018 | No plans on site // MO1 truss in garage missing h2.5 above 3rd stall // Missing nails in LUS26 hanger in garage, truss MO1A // Raised platform in garage missing 1 2X4 for LVL bearing // Need pad isolation in garage for post // Main level (2) sections where joist are 24" OC // Need to strap at plate break at living room where LS90 is above double 2X6 // Master bedroom missing LUS 26 at JO1B // Securely fasten posts in basement to pads // Need pad isolation (1) post in basement.
| NOAH | NOAH | | BFR | P | 5726549 |
ASPEN VIEW HOMES, LLC | BSP | P | 12/27/2017 | plot plan does not show deck | DALE | DALE | | BSP | P | 5723221 |
ASPEN VIEW HOMES, LLC | BSP | P | 12/06/2017 | narrow braced wall, porch frame and post ok | DALE | DALE | | BSP | P | 5704818 |
ASPEN VIEW HOMES, LLC | BFD | C | 11/06/2017 | Tie in to underdrain complete / | DALE | DALE | | BFD | C | 5677777 |
ASPEN VIEW HOMES, LLC | BFT | C | 11/06/2017 | Engineers observation Letter on file / | DALE | DALE | | BFT | C | 5676948 |
ASPEN VIEW HOMES, LLC | BFN | C | 11/06/2017 | Engineers observation Letter on file / Eufer OK / Foundation design on file / Soils report on file / 2000 psf / drain to habitable / float 1 1/2" / 10% grade / drain to street / overexcavation observation | DALE | DALE | | BFN | C | 5676944 |
ASPEN VIEW HOMES, LLC | BFT | P | 10/12/2017 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFT | P | 5653915 |
ASPEN VIEW HOMES, LLC | BFN | P | 10/12/2017 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFN | P | 5653914 |
PEAK ELECTRIC INC. | E= | C | 02/07/2018 | no a/c | TIMA | TIMA | | E= | C | 5759547 |
PEAK ELECTRIC INC. | ER | C | 12/28/2017 | #8 AL to oven/range / 1 - #14 multiwire circuit / No Cent Vac / Unfinished Basement / | TIMA | TIMA | | ER | C | 5724326 |
PEAK ELECTRIC INC. | ES | C | 12/27/2017 | Residential Underground: 200 amp 3/w new res. needs meter set | TIMA | TIMA | | ES | C | 5723015 |
PEAK ELECTRIC INC. | ER | R | 12/27/2017 | add recept 6' on stairway wall at front entry,wire can light in master bath | TIMA | TIMA | | ER | R | 5723014 |
PEAK ELECTRIC INC. | EUG | C | 12/04/2017 | | TIMA | TIMA | | EUG | C | 5701311 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | C | 02/16/2018 | | MARK | MARK | | H= | C | 5767707 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | P | 02/15/2018 | Missing toe kick in kitchen, wires on B vent, missing T&P drain pipe. Note: Unfinished basement, a/c,osa. | MARK | MARK | | H= | P | 5766804 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HC | C | 12/28/2017 | RELEASE METER | DUSTINS | DUSTINS | | HC | C | 5724453 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | C | 12/28/2017 | | DUSTINS | DUSTINS | | HRR | C | 5724452 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | P | 12/27/2017 | B-vent lacks clearance to combustibles on main level. Rest ok. BY FINAL: Outside air cap needs a screen in it. B-vent needs clearance from wires in basement. NOTES: Outside air to furnace return, unfinished basement, no A/C. | DUSTINS | DUSTINS | | HRR | P | 5723588 |
MD SERVICE PLUMBING, INC. | HI | C | 12/15/2017 | 10 lb test ok. Note: 1" main. Furnace and water heater only. | MARK | MARK | | HI | C | 5714314 |
MD SERVICE PLUMBING, INC. | P= | C | 02/13/2018 | Correction made. | DANR | DANR | | P= | C | 5764436 |
MD SERVICE PLUMBING, INC. | P= | P | 02/08/2018 | Need trap guard mechanical room floor drain, rest ok, pvb installed, unfinished basement. | DANR | DANR | | P= | P | 5761217 |
MD SERVICE PLUMBING, INC. | PTO | C | 12/18/2017 | Test k. Note: 2 - VTR, sprinkler stub, unfinished basement AAV lav. | DANR | DANR | | PTO | C | 5715460 |
MD SERVICE PLUMBING, INC. | PB | C | 11/14/2017 | Corrections made | CALE | CALE | | PB | C | 5684580 |
MD SERVICE PLUMBING, INC. | PB | P | 11/13/2017 | Lost test / rest ok | CALE | CALE | | PB | P | 5682905 |
MD SERVICE PLUMBING, INC. | PB | R | 11/09/2017 | Lost Test / Re-Bed bathroom group Note: Water under footer | CALE | CALE | | PB | R | 5680851 |