JMB CONSTRUCTION LLC | B= | C | 07/20/2018 | Thermal in crawl & attic OK / verified smokes & COs throughout | RICHB | RICHB | | B= | C | 5910020 |
JMB CONSTRUCTION LLC | BSP | T | 12/29/2017 | PAID (REC#1519010) PLAN SPLICE FEE: $50 by: MICHAELA for Construction: Revise roof framing | MICHAELA | MICHAELA | | BSP | T | 5724960 |
JMB CONSTRUCTION LLC | BLA | C | 12/29/2017 | Lath okay. | COREY | COREY | | BLA | C | 5724937 |
JMB CONSTRUCTION LLC | BFR | C | 12/07/2017 | Previous items completed - training with Justin (residential addition construction) / plans reviewed onsite | RICHB | RICHB | | BFR | C | 5706639 |
JMB CONSTRUCTION LLC | BSP | P | 12/07/2017 | Training with Rich - Follow up frame inspection | JUSTINL | JUSTINL | | BSP | P | 5706636 |
JMB CONSTRUCTION LLC | BFN | C | 12/07/2017 | Stamped foundation design received / 1500 psf | RICHB | RICHB | | BFN | C | 5706633 |
JMB CONSTRUCTION LLC | BFT | P | 12/07/2017 | Still need stamped foundation design / Engineer observation for footers and interior pads received / Open hole received - 1500 PSF / No drain / 5% | JUSTINL | JUSTINL | | BFT | P | 5705818 |
JMB CONSTRUCTION LLC | BIN | R | 12/06/2017 | Need to complete BFN and BFR / missing insulation between studs at bay window at front of addition // No insulation in crawl space at time of inspection | JUSTINL | JUSTINL | | BIN | R | 5704908 |
JMB CONSTRUCTION LLC | BFR | R | 12/06/2017 | Still need to complete BFN / Need to tie balloon framed walls together at ridge and to lower walls at both front and back of addition / Need to update prints to show ledger call out for M01 trusses as well as hangers required / Missing 2x6's at drop beam attached to top flange of beam / Strap top plate above bay window at front of addition / Missing H2.5s at mono trusses in bay window / Finish nailing H2.5s at exterior wall on M01 trusses / Need to glue shims in beam pocket / Need to secure steel column to beam | JUSTINL | JUSTINL | | BFR | R | 5704904 |
JMB CONSTRUCTION LLC | BSP | T | 11/17/2017 | PAID (REC#1466620) PLAN SPLICE FEE: $50 by: MICHAELA for Construction: Revise exterior walls to 2x4 | MICHAELA | MICHAELA | | BSP | T | 5689463 |
JMB CONSTRUCTION LLC | BFR | P | 11/17/2017 | Reviewed open hole, foundation plan and foundation observations onsite - will need a copy of these prior to completing BFR / need to remove wood shim from beam pocket / 3" steel column needs anchored to pad / floor framing OK - no walls at this time / plans reviewed onsite | RICHB | RICHB | | BFR | P | 5689441 |
JMB CONSTRUCTION LLC | BFN | P | 10/26/2017 | Still need footing observation, open hole and file copy of foundation design / foundation wall dowels into existing are now epoxied / forms & reinforcement for interior pad OK / plans reviewed onsite | RICHB | RICHB | | BFN | P | 5668788 |
JMB CONSTRUCTION LLC | BFN | R | 10/25/2017 | Footing pored prior to inspection, need Eng letter of observation / Need open hole report / Need to epoxy dowels in existing foundation / All other wall re bar OK / Need foundation design for file / Need to inspect interior pad | NICK | NICK | | BFN | R | 5667025 |
P&L ELECTRIC INC. YOUR QUALITY CONNECTION | E= | C | 03/16/2018 | | GARYL | GARYL | | E= | C | 5791699 |
P&L ELECTRIC INC. YOUR QUALITY CONNECTION | E= | R | 03/14/2018 | supposes to be called in for Friday | GARYL | GARYL | | E= | R | 5788970 |
P&L ELECTRIC INC. YOUR QUALITY CONNECTION | ER | C | 12/05/2017 | living room addition | BRET | BRET | | ER | C | 5702311 |
ADVANTAGE HEATING AND COOLING | H= | C | 05/07/2018 | SEE IMAGES | JERRYF | JERRYF | | H= | C | 5836940 |
ADVANTAGE HEATING AND COOLING | H= | L | 05/03/2018 | CONTRACTOR TO CALL THIS INSPECTOR ON 5/4 BEFORE 8:30 AM | JERRYF | JERRYF | | H= | L | 5835428 |
ADVANTAGE HEATING AND COOLING | H= | P | 12/20/2017 | NEED ALL NEW DUCT WORK IN EXISTING AND NEW CRAWLSPACE INSULATED FOR VENTED CRAWLSPACE - NEED TO CLAIM ALL NEW HVAC IN NEW ADDITION ON PERMIT - IN DIRECT FURNACE AND VENT ARE OK | JERRYF | JERRYF | | H= | P | 5718254 |
ADVANTAGE HEATING AND COOLING | H= | L | 12/13/2017 | NEED ALL WORK TRANSFERRED TO L21264 - NO ACCESS | JERRYF | JERRYF | | H= | L | 5713656 |