POULSON CONSTRUCTION, INC. | B= | C | 03/16/2018 | IRC unit number 17M33419 / State sticker number 32832 / West and north decks under separate permit L36604 / Unfinished upstairs/attic space // Unfinished basement | SHAUN | SHAUN | | B= | C | 5791358 |
POULSON CONSTRUCTION, INC. | BFR | C | 03/16/2018 | Items completed / Garage frame okay | SHAUN | SHAUN | | BFR | C | 5791323 |
POULSON CONSTRUCTION, INC. | BTD | C | 03/16/2018 | Items completed | SHAUN | SHAUN | | BTD | C | 5791321 |
POULSON CONSTRUCTION, INC. | B= | P | 03/16/2018 | Beam pocket letter -- Schedule a new Building Final when above items are complete. | SHAUN | SHAUN | | B= | P | 5790723 |
POULSON CONSTRUCTION, INC. | BFR | P | 02/02/2018 | slider in AC construction calls for 2 kings e.e. -- still need to see garage framing | SCOTTS | SCOTTS | | BFR | P | 5755709 |
POULSON CONSTRUCTION, INC. | BTD | P | 02/02/2018 | isolate posts in basement/pin posts -- provide detail for beam pocket change -- marriage line ok | SCOTTS | SCOTTS | | BTD | P | 5755705 |
POULSON CONSTRUCTION, INC. | BSP | P | 01/31/2018 | Front porch frame okay | SHAUN | SHAUN | | BSP | P | 5753172 |
POULSON CONSTRUCTION, INC. | BSP | R | 01/29/2018 | Front porch fame inspection -- Plans call for 2- 1/4" x 4 1/2" Simpson SDS screws 16" o.c. at ledger connection | SHAUN | SHAUN | | BSP | R | 5750263 |
POULSON CONSTRUCTION, INC. | BFD | C | 11/29/2017 | | SCOTTS | SCOTTS | | BFD | C | 5697044 |
POULSON CONSTRUCTION, INC. | BFN | C | 11/29/2017 | | SCOTTS | SCOTTS | | BFN | C | 5697038 |
POULSON CONSTRUCTION, INC. | BFT | C | 11/28/2017 | open ex on file | SCOTTS | SCOTTS | | BFT | C | 5695338 |
POULSON CONSTRUCTION, INC. | BFN | P | 11/27/2017 | foundation observation on file/eufer noted -- complete BFT | SCOTTS | SCOTTS | | BFN | P | 5693948 |
POULSON CONSTRUCTION, INC. | BFT | P | 11/27/2017 | footing observation on file-- still need open ex | SCOTTS | SCOTTS | | BFT | P | 5693946 |
POULSON CONSTRUCTION, INC. | BFN | P | 11/21/2017 | provide engineering observations | SCOTTS | SCOTTS | | BFN | P | 5691246 |
POULSON CONSTRUCTION, INC. | BFT | P | 11/21/2017 | provide engineering observations | SCOTTS | SCOTTS | | BFT | P | 5691245 |
POULSON CONSTRUCTION, INC. | BFD | P | 11/21/2017 | provide engineering -- remove debris and concrete spoils from excavation -- drains to sump -- damp proofing ok | SCOTTS | SCOTTS | | BFD | P | 5691238 |
POULSON CONSTRUCTION, INC. | BFT | P | 11/20/2017 | AUTHORIZED INSPECTION BY ENGINEER | TERRI | TERRI | TERRI | BFT | P | 5690141 |
POULSON CONSTRUCTION, INC. | BFN | P | 11/20/2017 | AUTHORIZED INSPECTION BY ENGINEER | TERRI | TERRI | TERRI | BFN | P | 5690140 |
ELK CREEK ELECTRICAL COMPANY LLC | E= | C | 03/08/2018 | 30 amp a/c | TOMC | TOMC | | E= | C | 5783696 |
ELK CREEK ELECTRICAL COMPANY LLC | E= | R | 03/02/2018 | wire a/c,need wr rated exterior recepts on garage,need lamps for basement stairways to verify 3-way switching,protect wire in garage and basement,open j-box in basement | TIMA | TIMA | | E= | R | 5778750 |
ELK CREEK ELECTRICAL COMPANY LLC | ER | C | 02/23/2018 | unfinished basement and garage --- ok | TOMC | TOMC | | ER | C | 5773095 |
ELK CREEK ELECTRICAL COMPANY LLC | ES | C | 01/25/2018 | Residential Overhead: 200 amp 3w new res. ok to set meter ------- Inspected up to line side of service disconnect. -------------- UFER is not ir, located in basement | JOSEPH | JOSEPH | | ES | C | 5747298 |
ELK CREEK ELECTRICAL COMPANY LLC | EUG | C | 01/10/2018 | 3 wire URD from pole to home 4 wire URD from home to out-building. | JOSEPH | JOSEPH | | EUG | C | 5734193 |
MILLER HEATING & AIR CONDITIONING, INC. | H= | C | 03/15/2018 | unfinished basement | TED | TED | | H= | C | 5790315 |
MILLER HEATING & AIR CONDITIONING, INC. | HRR | C | 03/15/2018 | correction made | TED | TED | | HRR | C | 5790309 |
MILLER HEATING & AIR CONDITIONING, INC. | HRR | P | 03/14/2018 | need the following-- seal water heater vent at collar per manufactures installations, secure condensate drain to water heater. note: unfinished basement, outside air to return, direct vent furnace, indirect vent water heater, a/c complete. | PAULO | PAULO | | HRR | P | 5788394 |
MILLER HEATING & AIR CONDITIONING, INC. | HRR | R | 03/12/2018 | complete fireplace venting, need 4 feet clearance under opening window to furnace vent outlet, complete water outlet venting, need water heater install paper work, install manufacture vent connection at water heater (not a furnco coupling ), run water heater condensate drain, broken supply in basement ceiling in kitchen area, note: unfinished basement, a/c installed, outside air to return | TED | TED | | HRR | R | 5786662 |
NASRALLAH PLUMBING & HEATING, INC. | HO | C | 01/29/2018 | 10# test ok. note: 1/2" poly at 60' to home, tracer wire installed. L.P. | PAULO | PAULO | | HO | C | 5749949 |
SPRINGS GAS, INC. | HI | C | 01/26/2018 | 10# test ok. note: 1 1/4" main at 80' to 1- furnace, 1- tank less water heater, 1- cook top and 1- fire place. | PAULO | PAULO | | HI | C | 5748610 |
AFAB PLUMBING LLC | P= | C | 03/13/2018 | unfinished basement | TED | TED | | P= | C | 5787751 |
AFAB PLUMBING LLC | PTO | C | 03/13/2018 | correction made | TED | TED | | PTO | C | 5787741 |
AFAB PLUMBING LLC | P= | R | 03/12/2018 | see pto note | TED | TED | | P= | R | 5786672 |
AFAB PLUMBING LLC | PTO | R | 03/12/2018 | install aav on basement lav riser, note: unfinished basement | TED | TED | | PTO | R | 5786639 |
AFAB PLUMBING LLC | P= | P | 03/12/2018 | certificate of potable water in images | TED | TED | | P= | P | 5785637 |
POULSON CONSTRUCTION, INC. | PWO | C | 02/22/2018 | 1 line run from well into house basement through wall, 2 lines run from basement out to old pressure pit connecting to yard hydrants, at final will need backflow protection on these 2 lines, will need certificate of potable water | TED | TED | | PWO | C | 5771913 |
AFAB PLUMBING LLC | PB | C | 11/29/2017 | Test ok. Note Sewage ejector, no water under footer. | DANR | DANR | | PB | C | 5696963 |
POULSON CONSTRUCTION, INC. | XMS | T | 01/31/2018 | PAID (REC#1750200): PLAN SPLICE FEE: $50 by: JUSTINC for Mechanical: splice to remove upper level from conditioned space | JUSTINC | JUSTINC | | XMS | T | 5753493 |