COLARELLI CONSTRUCTION, INC. | B= | C | 12/22/2017 | All other required Final inspections are complete. (This is a computer generated result) | RICHB | RICHB | | B= | C | 5720872 |
COLARELLI CONSTRUCTION, INC. | B= | P | 12/15/2017 | Interior finish complete pending other Finals. Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2), External Agency Inspection Z= by ZONING is not Completed yet (Contact: 719-385-5982), ARTISAN PIPE SYSTEMS, INC. Plumbing Final Inspection is not Completed yet. | RICHB | RICHB | | B= | P | 5714128 |
ARTISAN PIPE SYSTEMS, INC. | BSP | T | 12/05/2017 | PAID (REC#1469502) PLAN SPLICE FEE: $50 by: TCRIPPEN for Plumbing: plumbing splice 12-5-2017 | TCRIPPEN | TCRIPPEN | | BSP | T | 5703046 |
FOSTER ELECTRIC CORPORATION | BSP | P | 12/04/2017 | PLAN SPLICE: (No Fee) by: BERTHA for Electrical: Added CP-1 and removed EWC. | BERTHA | BERTHA | | BSP | P | 5701270 |
COLARELLI CONSTRUCTION, INC. | BFR | P | 11/06/2017 | Need Mechanical attached to permit / wall framing OK pending other Roughs / ceiling framing (see S-1) OK pending other Roughs / discussed accessible elements / plans reviewed onsite | RICHB | RICHB | | BFR | P | 5677512 |
FOSTER ELECTRIC CORPORATION | E= | C | 12/12/2017 | Correction complete / | ROB | ROB | | E= | C | 5709704 |
FOSTER ELECTRIC CORPORATION | E= | P | 12/08/2017 | need panel schedule | GARYL | GARYL | | E= | P | 5707502 |
FOSTER ELECTRIC CORPORATION | ER | C | 12/07/2017 | Rough in for ceiling ok / | ROB | ROB | | ER | C | 5706909 |
FOSTER ELECTRIC CORPORATION | ES | C | 11/27/2017 | Commercial Service: 200 amp UG NEW Fed From Bussed Wireway Ok to set Meter / | ROB | ROB | | ES | C | 5694128 |
FOSTER ELECTRIC CORPORATION | ES | R | 11/21/2017 | Need to remove ground wire from new service to bussed wireway----Meyers Hub at bussed gutter needs to be service rated / | ROB | ROB | | ES | R | 5691921 |
FOSTER ELECTRIC CORPORATION | ER | P | 11/09/2017 | Panel can and conduit stubs out of top ok for rough in / | ROB | ROB | | ER | P | 5680832 |
FOSTER ELECTRIC CORPORATION | ER | P | 11/06/2017 | Pipe stubbed up for floor boxes, additional switches ok--rough in ok for 107,109,110,116,117--Will need dead front GFI at accessible location or GFI breaker for Dishwasher / | ROB | ROB | | ER | P | 5677161 |
FOSTER ELECTRIC CORPORATION | ER | P | 10/27/2017 | from east wall of room 106 east to the front of store , west wall east to front of store OK to one side --- contractor has to extend floor boxes up the wall and two switches need wired | CRAIGS | CRAIGS | | ER | P | 5670171 |
FOSTER ELECTRIC CORPORATION | ESL | C | 10/27/2017 | | CRAIGS | CRAIGS | | ESL | C | 5670162 |
BRUNO'S MECHANICAL INC. | H= | C | 12/13/2017 | TAB REPORT RECEIVED - ALL OK | JERRYF | JERRYF | | H= | C | 5710827 |
BRUNO'S MECHANICAL INC. | H= | R | 12/12/2017 | NEED OUTSIDE AIR CFM STATED ON TAB REPORT PER PREVIOUS NOTES | JERRYF | JERRYF | | H= | R | 5709531 |
BRUNO'S MECHANICAL INC. | H= | R | 12/11/2017 | NEED TAB REPORT TO STATE ALL DESIGN AIRFLOW REQUIREMENTS AND OSA DESIGN AND ACTUAL OSA | JERRYF | JERRYF | | H= | R | 5708275 |
BRUNO'S MECHANICAL INC. | H= | P | 12/06/2017 | CORRECTION MADE AT PVC IN PLENUM - STILL NEED TAB REPORT | JERRYF | JERRYF | | H= | P | 5705566 |
BRUNO'S MECHANICAL INC. | H= | P | 12/01/2017 | NEED TAB REPORT AND PVC DRAIN PROTECTED DOWN TO TOP OF WALL AT RESTROOM - ATTACH TAB AND PICTURE OF CORRECTION TO NEXT INSPECTION REQUEST - REST OK | JERRYF | JERRYF | | H= | P | 5700397 |
BRUNO'S MECHANICAL INC. | HD | P | 11/13/2017 | ABOVE CEILING SA / RA AND EXHAUST OK - STILL NEED ROOF INSPECTION - VERIFY ROOF AND REMOTE INDICATORS AT FUTURE INSPECTION - NEED PVC ROOF DRAIN PROTECTED IN RA PLENUM AT FINAL | JERRYF | JERRYF | | HD | P | 5683511 |
ARTISAN PIPE SYSTEMS, INC. | P= | C | 12/06/2017 | **updated notes 12/21/17 as follows--d.f. rough in only, corrections made, see images | JOHNS | JOHNS | | P= | C | 5705428 |
ARTISAN PIPE SYSTEMS, INC. | PTO | C | 11/06/2017 | GC TO ATTACH MECH PERMIT, REVISE PLANS TO SHOW DELETING OF INDIVIDUAL VENTS AND ADDING CWV THROUGH OUT and deleting the d.f., rest ok for dwv and water. note: vtr (1) 4", cwv @ all lavs / sinks (vent for both water closets is the vtr), NEED TO CHECK WATER HTR @ FINAL, VERIFY FREEZE PRO WITH PICS @ FINAL | JOHNS | JOHNS | | PTO | C | 5677350 |
ARTISAN PIPE SYSTEMS, INC. | PB | C | 10/27/2017 | ok for test and design, WILL NEED TO REVISE PLANS @ TOP OUT TO SHOW DELETION OF VENTS AND ADDED CWV @ ALL LAVS AND SINKS, PLEASE HAVE PLUMBER ON SITE @ PTO INSPECTION
*CWV @ KIT SINK (DISPOSAL?? WILL REQUIRE A AAV IF SO, CLARIFY @ PTO) | JOHNS | JOHNS | | PB | C | 5669589 |