LAURIA BUILDERS & LAND, LLC. | B= | C | 04/12/2018 | finished basement, no deck, slab | DALE | DALE | | B= | C | 5815912 |
LAURIA BUILDERS & LAND, LLC. | B= | R | 04/11/2018 | locked at 2:54 | DALE | DALE | | B= | R | 5814435 |
LAURIA BUILDERS & LAND, LLC. | B= | P | 04/10/2018 | need ladder at attic access -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | DALE | DALE | | B= | P | 5812817 |
LAURIA BUILDERS & LAND, LLC. | BIN | C | 01/10/2018 | | BRIANB | BRIANB | | BIN | C | 5734642 |
LAURIA BUILDERS & LAND, LLC. | BFR | C | 01/10/2018 | corrections okay / garage portal wall corrections okay | BRIANB | BRIANB | | BFR | C | 5734641 |
LAURIA BUILDERS & LAND, LLC. | BLA | C | 01/10/2018 | | BRIANB | BRIANB | | BLA | C | 5734640 |
LAURIA BUILDERS & LAND, LLC. | BFR | P | 01/08/2018 | missing VTCR clips 48" OC over framing in garage / missing 1 ing EE east master bath window / fireplace cantilever calls for 2 Ks and 2 Ts EE / cut access to over framing in front bed dormer / secure post to beam and beam to pad in S basement bathroom / secure post to beam east side of stairs / missing 3 A note ST22s at SE corner / OK to insulate | LONNYS | LONNYS | | BFR | P | 5732158 |
LAURIA BUILDERS & LAND, LLC. | BSP | P | 12/15/2017 | missing 1000lb strap at garage portal wall header - can check at frame inspection / portal wall fastening okay / front and rear porch lid - posts okay | BRIANB | BRIANB | | BSP | P | 5714249 |
LAURIA BUILDERS & LAND, LLC. | BFD | C | 11/20/2017 | drain installed habitable to sump pit / damp proof okay | BRIANB | BRIANB | | BFD | C | 5690387 |
LAURIA BUILDERS & LAND, LLC. | BFN | C | 11/20/2017 | Engineers observation Letter on file / Eufer OK / Foundation design on file / Soils report on file / 2000 psf / habitable drain | BRIANB | BRIANB | | BFN | C | 5690386 |
LAURIA BUILDERS & LAND, LLC. | BFT | C | 11/20/2017 | Engineers observation Letter on file | BRIANB | BRIANB | | BFT | C | 5690377 |
LAURIA BUILDERS & LAND, LLC. | BFT | P | 10/27/2017 | AUTHORIZED INSPECTION BY ENGINEER | RITA | RITA | RITA | BFT | P | 5669423 |
LAURIA BUILDERS & LAND, LLC. | BFN | P | 10/27/2017 | AUTHORIZED INSPECTION BY ENGINEER | RITA | RITA | RITA | BFN | P | 5669422 |
LONGHORN ELECTRIC, INC. | E= | C | 04/03/2018 | | JOSEPH | JOSEPH | | E= | C | 5806172 |
LONGHORN ELECTRIC, INC. | E= | R | 04/02/2018 | Garage wall receptacles missing GFCI protection. --------- Notes: 25 amp ac unit | JOSEPH | JOSEPH | | E= | R | 5805695 |
LONGHORN ELECTRIC, INC. | ES | C | 01/03/2018 | Residential Underground: 200 amp 3w new res meter in need reseal | JOSEPH | JOSEPH | | ES | C | 5727775 |
LONGHORN ELECTRIC, INC. | ER | C | 01/03/2018 | Finished basement -------- No vac ------- 10/3 -------- UFER is ir | JOSEPH | JOSEPH | | ER | C | 5727749 |
LONGHORN ELECTRIC, INC. | EUG | C | 12/18/2017 | | JOSEPH | JOSEPH | | EUG | C | 5716119 |
ARROW HAWK HEATING, LLC | H= | C | 04/09/2018 | note: partial finished basement, outside air to return, direct vent furnace, a/c complete, mantel ok, 400 CFM on range hood. | PAULO | PAULO | | H= | C | 5810925 |
MJB PLUMBING AND HEATING, INC | H= | C | 04/06/2018 | note: partial finished basement, outside air to return, direct vent furnace, a/c complete, mantel ok. | PAULO | PAULO | | H= | C | 5810399 |
MJB PLUMBING AND HEATING, INC | HI+ | C | 04/06/2018 | gas line ok. note: added 20' of 1/2" blk to dryer. note: 1 1/4" main at 120' to 1- furnace, 1- water heater, 1- range, 1- fire place and 1- dryer. | PAULO | PAULO | | HI+ | C | 5810384 |
MJB PLUMBING AND HEATING, INC | H= | P | 04/04/2018 | leak on gas line at T to dryer. WHAT ARE THE CFM TO THE RANGE HOOD? note: partial finished basement, outside air to return, direct vent furnace, a/c complete, mantel ok. | PAULO | PAULO | | H= | P | 5807840 |
MJB PLUMBING AND HEATING, INC | HI+ | R | 04/04/2018 | leak at T to dryer. | PAULO | PAULO | | HI+ | R | 5807837 |
ARROW HAWK HEATING, LLC | H= | P | 03/28/2018 | need an HI+ permit for added gas line to dryer (gas line to dryer is all exposed). WHAT ARE THE CFM TO THE RANGE HOOD? note: partial finished basement, outside air to return, direct vent furnace, a/c complete, mantel ok. | PAULO | PAULO | | H= | P | 5801463 |
MJB PLUMBING AND HEATING, INC | HC | C | 01/05/2018 | RELEASE METER | PAULO | PAULO | | HC | C | 5730201 |
MJB PLUMBING AND HEATING, INC | HI | C | 01/05/2018 | 10# test ok. note: 1 1/4" main at 120' to 1- furnace, 1- water heater, 1- range and 1- fire place. | PAULO | PAULO | | HI | C | 5730186 |
ARROW HAWK HEATING, LLC | HRR | C | 12/29/2017 | FINISHED BASEMENT, A/C ROUGH, OUTSIDE AIR TO RETURN, EQUIPMENT MATCHES PLAN | RICKR | RICKR | | HRR | C | 5725028 |
MJB PLUMBING AND HEATING, INC | P= | C | 04/06/2018 | correction made | JOSEPHD | JOSEPHD | | P= | C | 5810616 |
MJB PLUMBING AND HEATING, INC | P= | P | 04/04/2018 | need expansion tank, need to seal lid for ejector pit rubber piece at vent loose, need fall protection at pit, support water main by ejector pit, rest ok note: partial finished basement, | JOSEPHD | JOSEPHD | | P= | P | 5807831 |
MJB PLUMBING AND HEATING, INC | PTO | C | 01/04/2018 | note: finished basement, vtr, caps on roof | JOSEPHD | JOSEPHD | | PTO | C | 5728847 |
MJB PLUMBING AND HEATING, INC | PB | C | 11/29/2017 | | JOSEPHD | JOSEPHD | | PB | C | 5697301 |