HOMEOWNER | B= | C | 06/18/2018 | finished basement, deck in, no stairs | DALE | DALE | | B= | C | 5877635 |
HOMEOWNER | B= | R | 06/15/2018 | need to complete BFR and BIN / upstairs bedrooms missing CO detector in hall / graspable hand rail to basement needs to be continuous from nose of top riser to nose of bottom riser / upon further inspection - insulation missing air barrier in mechanical room | LONNYS | LONNYS | | B= | R | 5876097 |
HOMEOWNER | BIN | P | 06/15/2018 | status changed to partial / need to complete BFR | LONNYS | LONNYS | | BIN | P | 5876076 |
HOMEOWNER | BFR | P | 06/15/2018 | status changed to partial / upon further inspection deck post caps need to be installed in pairs on both end posts | LONNYS | LONNYS | | BFR | P | 5876065 |
HOMEOWNER | BSP | P | 06/12/2018 | deck piers ok | DALE | DALE | | BSP | P | 5871270 |
HOMEOWNER | BSP | R | 06/11/2018 | 3 deck piers not on plans, has 2 outside 12", middle 18" piers | DALE | DALE | | BSP | R | 5870994 |
HOMEOWNER | BLA | C | 04/20/2018 | lath OK / no patios poured at time of inspection | LONNYS | LONNYS | | BLA | C | 5822975 |
HOMEOWNER | BFR | P | 04/09/2018 | picture of post connection on file / still need to inspect deck framing | LONNYS | LONNYS | | BFR | P | 5811009 |
HOMEOWNER | BIN | P | 04/06/2018 | insulation OK pending BFR | LONNYS | LONNYS | | BIN | P | 5809895 |
HOMEOWNER | BFR | P | 04/06/2018 | need to connect post in rear master suit to foundation - may upload picture / still need to inspect deck framing / received truss fix for A6 | LONNYS | LONNYS | | BFR | P | 5809894 |
HOMEOWNER | BFR | P | 03/30/2018 | need steel column under FG1 at rear bedroom / FHA plate at over bored top plate at master bath / 2 HTS16 at EG3 at garage / install roof jack at garage b-vent / porch frame and post ok / no deck at this time | DALE | DALE | | BFR | P | 5803954 |
HOMEOWNER | BSP | P | 03/29/2018 | foam is for holes in floor, fireblock has not been done
| DALE | DALE | | BSP | P | 5802977 |
HOMEOWNER | BFD | C | 12/11/2017 | Drain is usable and daylights northwest and northeast corners of foundation -- Damp proofing OK | DAKOTAB | DAKOTAB | | BFD | C | 5708840 |
HOMEOWNER | BIN | C | 12/07/2017 | 2" R10 OK at walkout | LONNYS | LONNYS | | BIN | C | 5706191 |
HOMEOWNER | BFT | C | 12/05/2017 | stamped open hole received | LONNYS | LONNYS | | BFT | C | 5702681 |
HOMEOWNER | BFN | C | 12/05/2017 | stamped open hole received / foundation OK / ufer verified / bearing capacity verified / NEED TO INSPECT DECK PIERS | LONNYS | LONNYS | | BFN | C | 5702675 |
HOMEOWNER | BFT | P | 11/27/2017 | footings okay// foundation design on file// feild copy of open hole on file// 5000 psf// still need stamped copy of open hole | LUKES | LUKES | | BFT | P | 5694697 |
HOMEOWNER | E= | C | 05/31/2018 | | BRET | BRET | | E= | C | 5861219 |
HOMEOWNER | EP | C | 05/29/2018 | 100 amp 4/w to sub panel ok | CRAIG | CRAIG | | EP | C | 5858135 |
HOMEOWNER | E= | R | 05/29/2018 | install inter system bonding terminal ---------- gfi all kitchen plugs that includes island plugs ------- island plugs to low needs to be 6" from bottom of counter top --------- gfi all plugs in mech room ------------ in use cover in back of house up side down --------- install test lights in garage door plugs ----------- ground metal boxes in well disconnect and island ----------- in sub panel circuit 7 won' t trip ----------- sub panel ok | CRAIG | CRAIG | | E= | R | 5858134 |
HOMEOWNER | ES | C | 04/18/2018 | Residential Underground: 200 amp 3w new res meter in need reseal | JOSEPH | JOSEPH | | ES | C | 5820166 |
HOMEOWNER | ES | R | 04/09/2018 | Residential Underground: remove temp panel -------- service lateral to short | CRAIG | CRAIG | | ES | R | 5811083 |
HOMEOWNER | ER | C | 03/29/2018 | Finished basement --------- UFER is not ir --------- 2224 ser to sub (CHECK SUB AT FINAL) --------- 2 - 10 /3 ----- 6/3 al ---------- No vac | JOSEPH | JOSEPH | | ER | C | 5802656 |
MILLER HEATING & AIR CONDITIONING, INC. | H= | C | 06/13/2018 | | DUSTINS | DUSTINS | | H= | C | 5873539 |
MILLER HEATING & AIR CONDITIONING, INC. | H= | P | 06/12/2018 | BACK DRAFT DAMPER FOR MASTER BATH VENT STUCCO CLOSED. NEED INSTALL INSTRUCTIONS FOR FIREPLACE TO VERIFY MANTLE CLEARANCES. NOTES: OUTSIDE AIR TO RETURN, FINISHED BASEMENT, A/C ROUGH LINE SET AND COIL, HIGH/LOW GRILLES TO MECHANICAL ROOM. DUSTINS | KYLEW | KYLEW | | H= | P | 5872033 |
MILLER HEATING & AIR CONDITIONING, INC. | HC | C | 03/27/2018 | RELEASE METER | PAULO | PAULO | | HC | C | 5800500 |
MILLER HEATING & AIR CONDITIONING, INC. | HRR | C | 03/27/2018 | note: finished basement, outside air to return, indirect vent furnace, a/c rough and line set. (WATER HEATER NOT ON SITE AT THIS TIME). (BASEMENT FINISH APPROVED). | PAULO | PAULO | | HRR | C | 5800483 |
MILLER HEATING & AIR CONDITIONING, INC. | HRR | P | 03/22/2018 | duct design for full finished basement no on plans- need approved revised plans to include full basement duct design, missing S.A. in right side bedroom in basement per plans. RE INSPECT BASEMENT DUCT DESIGN. note: finished basement, outside air to return, indirect vent furnace, a/c rough and line set. (WATER HEATER NOT ON SITE AT THIS TIME). | PAULO | PAULO | | HRR | P | 5796612 |
HOMEOWNER | HI | C | 03/14/2018 | 10 lb TEST OK .( UNIT HEATER FOR GARAGE SHALL NOT TO BE OVER 118 K) NOTES: 1-1/4" MAIN 1-BBQ, 1- UNIT HEAT, 1- RANGE, 1- FIREPLACE, 1- WATER HEATER, 1- FURNACE. | LIDO | LIDO | | HI | C | 5789090 |
HOMEOWNER | P= | C | 06/15/2018 | corrections made potable water certification and pvb installed in images note: pvb installed | JOSEPHD | JOSEPHD | | P= | C | 5875424 |
HOMEOWNER | P= | P | 06/12/2018 | need potable water certification, need to mount pvb can submit photos, rest ok note: bathrooms in basement not finishing (finished up to sheet rock) | JOSEPHD | JOSEPHD | | P= | P | 5872000 |
HOMEOWNER | PTO | C | 03/15/2018 | note: finished basement, irrigation stub, check well tank connections at final, mixing valve under master lav, future wet bar, cwv @ laundry tub | JOSEPHD | JOSEPHD | | PTO | C | 5790021 |
HOMEOWNER | PWO | C | 12/19/2017 | connection at well made | JOSEPHD | JOSEPHD | | PWO | C | 5717009 |
HOMEOWNER | PWO | P | 12/14/2017 | Need to see tie-in at well head, rest OK, need potable water cert. by final | SHANEN | SHANEN | | PWO | P | 5712762 |
HOMEOWNER | PB | C | 12/11/2017 | note: pit lid cant be more than 2" below floor level or it will need an extension | JOSEPHD | JOSEPHD | | PB | C | 5709021 |
HOMEOWNER | XBS | T | 02/06/2018 | PAID (REC#1480526) PLAN SPLICE FEE: $50 by: DANM for Construction: Added 2 windows to south elevation | DANM | DANM | | XBS | T | 5758160 |
HOMEOWNER | XBS | T | 01/30/2018 | PAID (REC#1480526) PLAN SPLICE FEE: $50 by: SHELLEY for Construction: added basement finish | SHELLEY | SHELLEY | | XBS | T | 5751538 |