SC SCOTT CONSTRUCTION CONSULTING, L.L.C. | B= | C | 07/19/2018 | unfinished basement, deck in, no stairs | DALE | DALE | | B= | C | 5908735 |
SC SCOTT CONSTRUCTION CONSULTING, L.L.C. | BSP | P | 05/21/2018 | eng. on file for 3 2x10 and 1 2x12 at deck joist on file | DALE | DALE | | BSP | P | 5850325 |
SC SCOTT CONSTRUCTION CONSULTING, L.L.C. | BSP | P | 05/18/2018 | lath on deck ok | DALE | DALE | | BSP | P | 5849934 |
SC SCOTT CONSTRUCTION CONSULTING, L.L.C. | BSP | P | 05/17/2018 | plan calls for 3-2x12 joist south side | DALE | DALE | | BSP | P | 5847405 |
SC SCOTT CONSTRUCTION CONSULTING, L.L.C. | BIN | C | 04/18/2018 | | DAKOTAB | DAKOTAB | | BIN | C | 5820117 |
SC SCOTT CONSTRUCTION CONSULTING, L.L.C. | BFR | C | 04/13/2018 | eng. received for header at service door and basement window trimmers at rear | DALE | DALE | | BFR | C | 5817175 |
SC SCOTT CONSTRUCTION CONSULTING, L.L.C. | BLA | C | 04/06/2018 | Lath okay | TRENTP | TRENTP | | BLA | C | 5810753 |
SC SCOTT CONSTRUCTION CONSULTING, L.L.C. | BSP | P | 03/29/2018 | 2 post to beam south end of deck ok | DALE | DALE | | BSP | P | 5802915 |
SC SCOTT CONSTRUCTION CONSULTING, L.L.C. | BSP | P | 03/09/2018 | rear deck posts and lid OK | LONNYS | LONNYS | | BSP | P | 5784948 |
SC SCOTT CONSTRUCTION CONSULTING, L.L.C. | BSP | P | 03/09/2018 | narrow braced wall OK | LONNYS | LONNYS | | BSP | P | 5784945 |
SC SCOTT CONSTRUCTION CONSULTING, L.L.C. | BSP | R | 03/07/2018 | FRONT PORCH AND REAR DECK INSPECTION -- need to role block rear deck lid trusses / rear deck cover posts missing ST18 straps / rear deck posts and framing OK / front porch posts and lid OK | LONNYS | LONNYS | | BSP | R | 5782873 |
SC SCOTT CONSTRUCTION CONSULTING, L.L.C. | BSP | R | 03/07/2018 | NARROW BRACED WALL - need to 3" grid pattern full height of header / missing anchor bolts | LONNYS | LONNYS | | BSP | R | 5782854 |
SC SCOTT CONSTRUCTION CONSULTING, L.L.C. | BFD | C | 01/19/2018 | Drain around habitable // Tied in to sump // Damp proofing okay | SHAUN | SHAUN | | BFD | C | 5743279 |
SC SCOTT CONSTRUCTION CONSULTING, L.L.C. | BFI | C | 01/19/2018 | 24" R10 okay | SHAUN | SHAUN | | BFI | C | 5743278 |
SC SCOTT CONSTRUCTION CONSULTING, L.L.C. | BFN | C | 01/19/2018 | Footing and Foundation observations on file // Soils and open hole 1,500 psf // Foundation design 1,500 psf // Drain around habitable // Isolate, Float // Drain design | SHAUN | SHAUN | | BFN | C | 5743272 |
SC SCOTT CONSTRUCTION CONSULTING, L.L.C. | BFT | C | 01/19/2018 | Footing and Foundation observations on file // Soils and open hole 1,500 psf // Foundation design 1,500 psf // Drain around habitable // Isolate, Float // Drain design | SHAUN | SHAUN | | BFT | C | 5743269 |
SC SCOTT CONSTRUCTION CONSULTING, L.L.C. | BFT | P | 12/13/2017 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFT | P | 5711094 |
SC SCOTT CONSTRUCTION CONSULTING, L.L.C. | BFN | P | 12/13/2017 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFN | P | 5711093 |
FIRST RATE ELECTRICAL SERVICES, INC. | EP | C | 07/09/2018 | 100 amp 4/w to sub panel ok | CRAIG | CRAIG | | EP | C | 5896923 |
FIRST RATE ELECTRICAL SERVICES, INC. | E= | C | 07/09/2018 | | CRAIG | CRAIG | | E= | C | 5896918 |
FIRST RATE ELECTRICAL SERVICES, INC. | ES | C | 04/05/2018 | Residential Underground: 200 - amp 3 Wire service, ok to seal meter / | CRAIG | CRAIG | | ES | C | 5809313 |
FIRST RATE ELECTRICAL SERVICES, INC. | ES | R | 04/04/2018 | Unable to identify location of utility meter. ------------- Notes: Rest of 200 amp service good. | JOSEPH | JOSEPH | | ES | R | 5807478 |
FIRST RATE ELECTRICAL SERVICES, INC. | ER | C | 04/04/2018 | Unfinished basement ------- UFER is ir ------ 2224 ser to floated sub panel good ---- 2 - 10/3 ----- 6/3 al ----- No vac | JOSEPH | JOSEPH | | ER | C | 5807463 |
FIRST RATE ELECTRICAL SERVICES, INC. | EUG | C | 04/04/2018 | Saw direct burial splices in trench | JOSEPH | JOSEPH | | EUG | C | 5807462 |
REGIONAL HEATING AND AIR CONDITIONING, INC. | H= | C | 07/18/2018 | NOTE: UNFINISHED BASEMENT, DIRECT VENT FURNACE, A/C ROUGH COIL AND LINESET, OUTSIDE AIR TO RETURN DUCT | BILLS | BILLS | | H= | C | 5906452 |
REGIONAL HEATING AND AIR CONDITIONING, INC. | H= | P | 07/11/2018 | Still awaiting 2LB approval letter. Furnace manufacturer requires minimum 4" tall standpipe from T fitting at condensate drain piping per page 20 fig. 14. Cap suction line @ coil.Protect wiring entering furnace cabinet serving basement. NOTES: Unfinished basement 6 supplies, 2 returns, 1 transfer in stairwell. Outside air to main furnace return. 1- Direct vent furnace. A/C Rough coil and line-set to main furnace. | RANDYB | RANDYB | | H= | P | 5899562 |
REGIONAL HEATING AND AIR CONDITIONING, INC. | HRR | C | 04/10/2018 | NOTES: UNFINISHED BASEMENT, DIRECT VENT FURNACE, OUTSIDE AIR TO RETURN, A/C ROUGH COIL AND LINE SET | BENH | BENH | | HRR | C | 5813334 |
DAVIS GAS SHOP INC | HC | C | 03/15/2018 | RELEASE METER FOR 2LB SYSTEM THANKS | BENH | BENH | | HC | C | 5813335 |
DAVIS GAS SHOP INC | HI | C | 03/15/2018 | NEED 2LB LETTER BY FINAL AND REGULATOR IN PLACE, 10 LB TEST OK, 1" MAIN, 2 FURNACE, 2 WATER HEATERS 1 COOK TOP, 1 BBQ | BENH | BENH | | HI | C | 5790467 |
CHEYENNE PLUMBING & HEATING, INC. | P= | C | 07/18/2018 | note: unfinished basement, potable water certification sent to scanning, backflow for yard hydrant in utility room | JOSEPHD | JOSEPHD | | P= | C | 5906632 |
CHEYENNE PLUMBING & HEATING, INC. | PTO | C | 03/20/2018 | correction made | JOSEPHD | JOSEPHD | | PTO | C | 5793812 |
CHEYENNE PLUMBING & HEATING, INC. | PTO | P | 03/16/2018 | low test at powder room dwv, rest ok note: need to support pex from well and yard hydrant on wall by final, unfinished basement, backflow for yard hydrant at well tank in basement, running trap for laundry tub in garage at ceiling in utility room, mixing valve in LH master lav, aav in utility room LH side | JOSEPHD | JOSEPHD | | PTO | P | 5791063 |
HOMEOWNER | PWO | C | 03/09/2018 | note: backflow for yard hydrant at well tank, need potable water certification by final | JOSEPHD | JOSEPHD | | PWO | C | 5784915 |
CHEYENNE PLUMBING & HEATING, INC. | PB | C | 01/26/2018 | | SHANEN | SHANEN | | PB | C | 5749095 |