SOLID ROCK CONSTRUCTION, LLC | B= | C | 08/01/2018 | handrail and guardrails installed. | NATHAN | NATHAN | | B= | C | 5920233 |
SOLID ROCK CONSTRUCTION, LLC | B= | R | 07/31/2018 | need all guardrails completed at deck and entry / remaining items and areas okay. Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2). | NATHAN | NATHAN | | B= | R | 5919494 |
SOLID ROCK CONSTRUCTION, LLC | BFR | C | 07/30/2018 | Welding report on file | NICK | NICK | | BFR | C | 5917368 |
SOLID ROCK CONSTRUCTION, LLC | BFR | P | 07/18/2018 | Need Welding report / Welding report being uploaded does not have address of work inspected, also welding stamp is out of date / All framing OK pending welding report | NICK | NICK | | BFR | P | 5906927 |
SOLID ROCK CONSTRUCTION, LLC | BSP | P | 06/18/2018 | ADDITIONAL PLAN REVIEW TIME: (No Fee) From: BECKYA Revised floor framing for Deck | BECKYA | BECKYA | | BSP | P | 5877694 |
SOLID ROCK CONSTRUCTION, LLC | BIN | C | 05/18/2018 | Insulation OK / Check crawl space at final / Need frame complete | NICK | NICK | | BIN | C | 5849410 |
SOLID ROCK CONSTRUCTION, LLC | BFR | P | 05/18/2018 | Need welding report for steel to beam at back porch / Need to install steel for front porch / All other framing items complete | NICK | NICK | | BFR | P | 5849407 |
SOLID ROCK CONSTRUCTION, LLC | BFR | P | 05/16/2018 | Need to install anchor bolts with in 12" of sill plate breaks throughout / Need to splice plans to show new floor framing design / Need Eng for brackets used for beams in place of steel post on approved plans / Temp stairs installed at time of inspection / Need to inspect all exterior porches and decks / OK to insulate | NICK | NICK | | BFR | P | 5846630 |
SOLID ROCK CONSTRUCTION, LLC | BSP | P | 03/28/2018 | Portal frame wall for garage OK / All interior and exterior sheer walls OK per plans / Interior embedded hold down straps OK per detail A | NICK | NICK | | BSP | P | 5801854 |
SOLID ROCK CONSTRUCTION, LLC | BFI | C | 02/07/2018 | 2" rigid 30" deep | NATHAN | NATHAN | | BFI | C | 5759855 |
SOLID ROCK CONSTRUCTION, LLC | BFD | C | 02/07/2018 | drain is usable to daylight SE corner | NATHAN | NATHAN | | BFD | C | 5759848 |
SOLID ROCK CONSTRUCTION, LLC | BFN | C | 02/07/2018 | Engineers observation Letter on file / Eufer OK / Foundation design on file / Soils report on file / | NATHAN | NATHAN | | BFN | C | 5759065 |
SOLID ROCK CONSTRUCTION, LLC | BFT | C | 02/07/2018 | Engineers observation Letter on file / Soils report on file / | NATHAN | NATHAN | | BFT | C | 5759063 |
SOLID ROCK CONSTRUCTION, LLC | BFD | P | 02/07/2018 | drain to be around habitable or storage area, open excavation uploaded. | NATHAN | NATHAN | | BFD | P | 5759057 |
D & J QUALITY ELECTRIC INC | E= | C | 07/30/2018 | | BRIAN | BRIAN | | E= | C | 5918134 |
D & J QUALITY ELECTRIC INC | E= | P | 07/27/2018 | steamer disco and cb to small, all outside outlets need gfci, move HWH disco for proper clearance, dining rm outlets and cb not working, floor heat in master bath and lower bath have grd fault, master bed has several outlets out, attach FA permit to building permit, ------------------------30 amp a/c,60 amp hot tub prewire, many landscape spare circuits thru out exterior blanked off, | JOHNN | JOHNN | | E= | P | 5916431 |
D & J QUALITY ELECTRIC INC | ES | C | 06/15/2018 | Residential Underground: 300 AMP 3-W NEW RES---OK TO SET METER---- | BRIAN | BRIAN | | ES | C | 5876704 |
D & J QUALITY ELECTRIC INC | ER | C | 05/11/2018 | NOTES--NO CV---FINISHED BASEMENT----FIRE ALARM INSTALLED ---NEED PERMIT PULLED--- | BRIAN | BRIAN | | ER | C | 5842162 |
D & J QUALITY ELECTRIC INC | ER | R | 05/09/2018 | deck: remove 8 cans and #8cu nm cable where exposed to rain, will this area be completely dried in on final? master bath: middle sink needs outlet with in 3', FA not installed yet, FA contractor has to attach to permit and get rough inspection, --------------------------basement 100 amp sub panel,ok, no mcc, did not look 2 main panels,rev ufer, floor heat in bath rms, | JOHNN | JOHNN | | ER | R | 5839592 |
A & Z MECHANICAL, INC. | H= | C | 07/27/2018 | 10" barometric to mechanical for kitchen hood, 6" osa to furnace return, both furnaces are direct vented through roof, water heater is electric. 1- a/c. | MARK | MARK | | H= | C | 5916641 |
A & Z MECHANICAL, INC. | HC | C | 05/14/2018 | RELEASE METER | MARK | MARK | | HC | C | 5844512 |
A & Z MECHANICAL, INC. | HRR | C | 05/14/2018 | All corrections made. | MARK | MARK | | HRR | C | 5844166 |
A & Z MECHANICAL, INC. | HRR | P | 05/10/2018 | Need nail protection for furnace vents main level Bath area. Gas fireplace vent lacks clearance at wood. Note: Finished basement, 2- matching furnaces with direct vent systems. 1 barometric damper, 1- osa to return. 1- a/c coil and line set rough | MARK | MARK | | HRR | P | 5841464 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | HI | C | 04/23/2018 | 10 lb test ok, 1 1/4 main, 2 furnaces, 1 fireplace, 1 range, 1 barbecue, note: electric water heater. | TAYLOR | TAYLOR | | HI | C | 5824658 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | P= | C | 07/26/2018 | rp @ mech | JOHNS | JOHNS | | P= | C | 5914772 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | PTO | C | 04/23/2018 | finished basement, aav's at both sinks in kitchen, laundry sink, K.C. drain at crawl space, check water heater, meter, mixing valve for master tub, and steam generator by final. | TAYLOR | TAYLOR | | PTO | C | 5824661 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | PB | C | 02/20/2018 | | TAYLOR | TAYLOR | | PB | C | 5769766 |
SOLID ROCK CONSTRUCTION, LLC | XBS | T | 05/17/2018 | PAID (REC#1501110): PLAN SPLICE FEE: $50 by: SHELLEY for Construction: Floor framing changes. | SHELLEY | SHELLEY | | XBS | T | 5847545 |