CAMPBELL HOMES LTD. | B= | C | 07/02/2018 | Items corrected | TIMOTHYS | TIMOTHYS | | B= | C | 5890815 |
CAMPBELL HOMES LTD. | B= | P | 06/28/2018 | need CO alarm outside of upper floor bedrooms / need minimum 6'8" head room at stairs to basement / full finished basement - no decks -- Schedule a new Building Final when above items are complete. | DANE | DANE | | B= | P | 5888622 |
CAMPBELL HOMES LTD. | BFD | C | 06/28/2018 | all paperwork on file / drain inspected on 3/6 | DANE | DANE | | BFD | C | 5888602 |
CAMPBELL HOMES LTD. | BFN | C | 06/28/2018 | all paperwork on file | DANE | DANE | | BFN | C | 5888597 |
CAMPBELL HOMES LTD. | BIN | C | 04/24/2018 | | DAKOTAB | DAKOTAB | | BIN | C | 5825917 |
CAMPBELL HOMES LTD. | BFR | C | 04/24/2018 | Items corrected | DAKOTAB | DAKOTAB | | BFR | C | 5825916 |
CAMPBELL HOMES LTD. | BFN | C | 04/24/2018 | Foundation design received | DAKOTAB | DAKOTAB | | BFN | C | 5825902 |
CAMPBELL HOMES LTD. | BIN | R | 04/20/2018 | Need to complete BFN and BFD -- No inspection performed | DAKOTAB | DAKOTAB | | BIN | R | 5823142 |
CAMPBELL HOMES LTD. | BFR | P | 04/20/2018 | Still need to strap both top plates to header over fireplace -- Other items corrected | DAKOTAB | DAKOTAB | | BFR | P | 5823114 |
CAMPBELL HOMES LTD. | BFN | P | 04/20/2018 | Engineer letter for foundation received -- Still need foundation design | DAKOTAB | DAKOTAB | | BFN | P | 5823113 |
CAMPBELL HOMES LTD. | BFT | C | 04/20/2018 | Engineer letter for footing received -- Open hole received -- 2000 PSF - Drain usable - 10% | DAKOTAB | DAKOTAB | | BFT | C | 5823110 |
CAMPBELL HOMES LTD. | BSP | R | 04/17/2018 | Duplicate inspection request | DAKOTAB | DAKOTAB | | BSP | R | 5819085 |
CAMPBELL HOMES LTD. | BFR | P | 04/17/2018 | Still need open hole and foundation engineering -- OK to insulate -- Missing MTS12 at front of BG1 in garage per engineer letter -- Strap both top plates to header at fireplace -- Missing solid blocking in basement at cantilever | DAKOTAB | DAKOTAB | | BFR | P | 5819078 |
CAMPBELL HOMES LTD. | BSP | P | 04/13/2018 | Still need all foundation engineering -- Front porch post and lid OK -- Narrow braced wall OK | DAKOTAB | DAKOTAB | | BSP | P | 5816468 |
CAMPBELL HOMES LTD. | BFD | R | 03/06/2018 | Need open hole and foundation engineering -- Drain is usable to street -- Damp proofing OK | DAKOTAB | DAKOTAB | | BFD | R | 5781230 |
CAMPBELL HOMES LTD. | BFN | P | 02/12/2018 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFN | P | 5762907 |
CAMPBELL HOMES LTD. | BFT | P | 02/12/2018 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFT | P | 5762908 |
POSITIVE ELECTRIC, LLC | E= | C | 06/18/2018 | 20 amp a/c | RANDY | RANDY | | E= | C | 5877062 |
POSITIVE ELECTRIC, LLC | ES | C | 04/13/2018 | Residential Underground: 150 amp 3/w new res | RANDY | RANDY | | ES | C | 5816175 |
POSITIVE ELECTRIC, LLC | ER | C | 04/13/2018 | 3-#8al, irreversible ufer, finished basement, no vac, a/c stub | RANDY | RANDY | | ER | C | 5816174 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | C | 05/31/2018 | High/low transfer grills to mechanical room. . AC rough line set. Finished basement. Outside air to return. | JEFFL | JEFFL | | H= | C | 5860605 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HC | C | 04/17/2018 | RELEASE METER | BILLS | BILLS | | HC | C | 5818453 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | C | 04/17/2018 | | BILLS | BILLS | | HRR | C | 5818452 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | P | 04/16/2018 | BASEMENT BATH EXHAUST FLEX IS SEPARATED ON BOTH SIDES OF THE SUPPLY DUCT IT CROSSES OVER, MARKED ON FRAMING BELOW WITH BLACK ARROWS. REMOVE JOIST BLOCKING AT RETURN AIR BAY AT BOTTOM OF STAIRS, MARKED WITH BLACK EX'S AND ARROWS | BILLS | BILLS | | HRR | P | 5818171 |
SPRINGS GAS, INC. | HI | C | 04/11/2018 | 10 lb test ok. Notes-- 1 1/4'' main.. 1 furnace.. 1 water heater.. 1 range.. 1 fireplace.. | JEFFL | JEFFL | | HI | C | 5813688 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | P | 04/10/2018 | Bath exhaust not complete in basement. Notes-- finished basement. AC rough line set. Outside air to return. | JEFFL | JEFFL | | HRR | P | 5812652 |
SPRINGS CUSTOM PLUMBING, INC. | P= | C | 06/15/2018 | Ok, finished basement, no irrigation. | DANR | DANR | | P= | C | 5876269 |
SPRINGS CUSTOM PLUMBING, INC. | PTO | C | 04/10/2018 | corrections made | JOSEPHD | JOSEPHD | | PTO | C | 5813317 |
SPRINGS CUSTOM PLUMBING, INC. | PTO | P | 04/09/2018 | changed to PTO inspection, water turned off to all fixtures at manifold, need nail protection at master lav bottom plate, rest ok note: finished basement, aav @ basement lav, wet bar | JOSEPHD | JOSEPHD | | PTO | P | 5811270 |
SPRINGS CUSTOM PLUMBING, INC. | PB | C | 03/14/2018 | | JOSEPHD | JOSEPHD | | PB | C | 5789033 |