ASPEN VIEW HOMES, LLC | B= | C | 08/21/2018 | corrections okay / training with PPRBD inspector Chuck | BRIANB | BRIANB | | B= | C | 5940897 |
ASPEN VIEW HOMES, LLC | B= | P | 08/07/2018 | window sill at (2) front basement bedroom windows exceed 44" off of the finished floor / finished basement / no deck -- Schedule a new Building Final when above items are complete. | BRIANB | BRIANB | | B= | P | 5926431 |
ASPEN VIEW HOMES, LLC | BLA | C | 06/14/2018 | | BRIANB | BRIANB | | BLA | C | 5875288 |
ASPEN VIEW HOMES, LLC | BIN | C | 06/06/2018 | | BRIANB | BRIANB | | BIN | C | 5866486 |
ASPEN VIEW HOMES, LLC | BFR | C | 06/06/2018 | corrections okay | BRIANB | BRIANB | | BFR | C | 5866469 |
ASPEN VIEW HOMES, LLC | BFR | P | 06/04/2018 | missing sheathing at interior side of garage portal wall per letter on file / finished basement / no deck installed / okay to insulate | BRIANB | BRIANB | | BFR | P | 5863591 |
ASPEN VIEW HOMES, LLC | BFR | R | 05/31/2018 | cancelled onsite by Aspen View superintendent Derek | BRIANB | BRIANB | | BFR | R | 5860592 |
ASPEN VIEW HOMES, LLC | BSP | P | 05/23/2018 | letter for garage portal wall on file | BRIANB | BRIANB | | BSP | P | 5852980 |
ASPEN VIEW HOMES, LLC | BSP | R | 05/01/2018 | single car portal wall does not meet min. width requirements per portal wall details / front porch lid and posts okay | BRIANB | BRIANB | | BSP | R | 5832504 |
ASPEN VIEW HOMES, LLC | BFD | C | 04/05/2018 | tie into under drain complete - photo on file / foundation inspections completed | BRIANB | BRIANB | | BFD | C | 5808265 |
ASPEN VIEW HOMES, LLC | BFN | C | 04/05/2018 | Engineers observation Letter on file / Eufer OK / Foundation design on file / Soils report on file / 2000 psf / drain habitable space / tie into under drain complete - photo on file | BRIANB | BRIANB | | BFN | C | 5808263 |
ASPEN VIEW HOMES, LLC | BFT | C | 04/05/2018 | Engineers observation Letter on file | BRIANB | BRIANB | | BFT | C | 5808258 |
ASPEN VIEW HOMES, LLC | BFD | P | 04/04/2018 | need all foundation paperwork / need to verify drain tie in to street / drain is usable to street - damp proofing OK | LONNYS | LONNYS | | BFD | P | 5808018 |
ASPEN VIEW HOMES, LLC | BFN | P | 02/12/2018 | AUTHORIZED INSPECTION BY ENGINEER | MATTHEWM | MATTHEWM | MATTHEWM | BFN | P | 5763549 |
ASPEN VIEW HOMES, LLC | BFT | P | 02/12/2018 | AUTHORIZED INSPECTION BY ENGINEER | MATTHEWM | MATTHEWM | MATTHEWM | BFT | P | 5763550 |
PEAK ELECTRIC INC. | E= | C | 07/19/2018 | 20 AMP a/c OK | CRAIGS | CRAIGS | | E= | C | 5908541 |
PEAK ELECTRIC INC. | ES | C | 05/18/2018 | Residential Underground: 200-amp 3 Wire service, ok to set meter / | ROB | ROB | | ES | C | 5849212 |
PEAK ELECTRIC INC. | ER | C | 05/18/2018 | #8 AL to oven/range / 10-2 to A/C / 10-3 to Dryer / 1 - #14 multiwire circuit / Finished Basement /Non- Irreversible UFER connection / No Cent Vac / | ROB | ROB | | ER | C | 5849210 |
COMFORT CONTROL, INC. | H= | C | 07/30/2018 | NOTE; LOUVER DOOR TO MECHANICAL ROOM, A/C COMPLETE | TREVORH | TREVORH | | H= | C | 5918418 |
COMFORT CONTROL, INC. | H= | P | 07/27/2018 | Furnace vent is disconnected at double wall elbow. Notes-- finished basement. AC rough coil and line set. Outside air to return. | JEFFL | JEFFL | | H= | P | 5917055 |
COMFORT CONTROL, INC. | HC | C | 05/21/2018 | RELEASE METER | JEFFL | JEFFL | | HC | C | 5851546 |
COMFORT CONTROL, INC. | HRR | C | 05/21/2018 | **Matching furnace or updated equipment certificate needed by final**. Notes-- Finished basement. AC rough coil and line set. Outside air to return. | JEFFL | JEFFL | | HRR | C | 5851545 |
MD SERVICE PLUMBING, INC. | HI | C | 05/18/2018 | 10 lb TEST OK . NOTES: 1" MAIN, 1- FIREPLACE , 1- FURNACE, 1- WATER HEATER. | LIDO | LIDO | | HI | C | 5849653 |
MD SERVICE PLUMBING, INC. | P= | C | 07/24/2018 | correction made | TED | TED | | P= | C | 5912475 |
MD SERVICE PLUMBING, INC. | P= | P | 07/23/2018 | could not test master and 1st floor hall showers, glass walls being installed, rest ok, note: finished basement, laundry sink rough only, 3/4'' pvb installed | TED | TED | | P= | P | 5910550 |
MD SERVICE PLUMBING, INC. | PTO | C | 05/09/2018 | finished basement, 2- basement bathrooms, both basement lavs aav, aav bar sink, sprinkler stub | TED | TED | | PTO | C | 5839828 |
MD SERVICE PLUMBING, INC. | PB | C | 04/11/2018 | ok, water under footer | TED | TED | | PB | C | 5813975 |