VANTAGE HOMES CORP. | B= | C | 07/09/2018 | final OK pending other finals | DANE | DANE | | B= | C | 5895985 |
VANTAGE HOMES CORP. | B= | P | 07/06/2018 | insulation certificate received / CO alarm installed OK -- Schedule a new Building Final when above items are complete. | DANE | DANE | | B= | P | 5895545 |
VANTAGE HOMES CORP. | B= | P | 07/03/2018 | need to upload insulation certificate / need CO alarm outside of master / full finished basement / no decks -- Schedule a new Building Final when above items are complete. | DANE | DANE | | B= | P | 5892343 |
VANTAGE HOMES CORP. | BIN | C | 04/24/2018 | | DANE | DANE | | BIN | C | 5825626 |
VANTAGE HOMES CORP. | BFR | C | 04/23/2018 | items corrected | DANE | DANE | | BFR | C | 5824499 |
VANTAGE HOMES CORP. | BFR | R | 04/19/2018 | need to install roof vents and doors to dry in / missing lateral brace at F3 over stairs - lateral that is missing goes on vertical over hangers | DANE | DANE | | BFR | R | 5821853 |
VANTAGE HOMES CORP. | BSP | P | 03/23/2018 | narrow wall and circle A note straps OK | DANE | DANE | | BSP | P | 5797781 |
VANTAGE HOMES CORP. | BSP | P | 03/23/2018 | front and rear porch lids OK / rear porch posts OK / narrow wall OK / circle A straps OK | DANE | DANE | | BSP | P | 5797776 |
VANTAGE HOMES CORP. | BFD | C | 03/16/2018 | Engineers observation letter received | DANE | DANE | | BFD | C | 5791725 |
VANTAGE HOMES CORP. | BFN | C | 03/16/2018 | Engineer letter for foundation received -- Eufer noted | DANE | DANE | | BFN | C | 5791722 |
VANTAGE HOMES CORP. | BFT | C | 03/16/2018 | open hole received- 2000 PSF - usable - 10% / footing and foundation observation received - eufer noted / foundation design received (bearing capacity verified) | DANE | DANE | | BFT | C | 5791720 |
VANTAGE HOMES CORP. | BSP | P | 03/16/2018 | photo of drain connection | DANE | DANE | | BSP | P | 5790481 |
VANTAGE HOMES CORP. | BFD | P | 02/12/2018 | AUTHORIZED INSPECTION BY ENGINEER | RITA | RITA | RITA | BFD | P | 5763609 |
VANTAGE HOMES CORP. | BFT | P | 02/12/2018 | AUTHORIZED INSPECTION BY ENGINEER | RITA | RITA | RITA | BFT | P | 5763608 |
VANTAGE HOMES CORP. | BFN | P | 02/12/2018 | AUTHORIZED INSPECTION BY ENGINEER | RITA | RITA | RITA | BFN | P | 5763607 |
D & J QUALITY ELECTRIC INC | E= | C | 07/02/2018 | | BRET | BRET | | E= | C | 5890974 |
D & J QUALITY ELECTRIC INC | E= | T | 06/29/2018 | PAID (REC#1512469): corrections not made from previous inspection ----------- install 250.94 ---------- no power to basement smoke in northwest bedroom --------- install cover plates in master bedroom ---------- ac ok 30 amp | CRAIG | CRAIG | | E= | T | 5889976 |
D & J QUALITY ELECTRIC INC | E= | R | 06/21/2018 | install intersystem bond, bed bath breaker will not hold all kitchen receptacles hanging out of wall , island receptacles cover by stone. complete re-inspect | BRET | BRET | | E= | R | 5881635 |
D & J QUALITY ELECTRIC INC | ER | C | 04/18/2018 | Correction complete / | ROB | ROB | | ER | C | 5820712 |
D & J QUALITY ELECTRIC INC | ES | C | 04/17/2018 | Residential Underground: 150 amp service new res. | BRET | BRET | | ES | C | 5819014 |
D & J QUALITY ELECTRIC INC | ER | R | 04/17/2018 | wiring removed for framing and plumbing. #8 cu cook top and oven, #8 al a/c no mcc, no ac, | BRET | BRET | | ER | R | 5819013 |
A & Z MECHANICAL, INC. | H= | C | 06/19/2018 | Note-- finished basement. AC complete. Outside air to return. Direct vent furnace. | JEFFL | JEFFL | | H= | C | 5878343 |
A & Z MECHANICAL, INC. | HC | C | 04/16/2018 | RELEASE METER | NANCY | NANCY | | HC | C | 5818299 |
A & Z MECHANICAL, INC. | HRR | C | 04/16/2018 | | NANCY | NANCY | | HRR | C | 5818223 |
A & Z MECHANICAL, INC. | HRR | P | 04/12/2018 | NEED WATER HEATER VENT INSTALLED NOTES: FINISH BASEMENT, DIRECT VENT FURNACE, OUTSIDE AIR TO RETURN, A/C ROUGH COIL AND LINE SET. | BENH | BENH | | HRR | P | 5815801 |
L & L GAS SHOP, LLC. | HI | C | 04/05/2018 | 10LB TEST OK | BENH | BENH | | HI | C | 5809476 |
L & L GAS SHOP, LLC. | HI | P | 04/03/2018 | LOW TEST SITTING AT 9 PSI, 1 1/4" MAIN, 1 FURNACE, 1 WATER HEATER, 2 FIREPLACE, 1 COOK TOP | BENH | BENH | | HI | P | 5806626 |
TEAM PLUMBING, INC. | P= | C | 06/29/2018 | pvb installed, finished basement. | TAYLOR | TAYLOR | | P= | C | 5889638 |
TEAM PLUMBING, INC. | PTO | C | 04/06/2018 | Finished basement, irrigation, AAV master bath and basement bath lavs | SHANEN | SHANEN | | PTO | C | 5810665 |
TEAM PLUMBING, INC. | PB | C | 03/06/2018 | Correction made | SHANEN | SHANEN | | PB | C | 5781382 |
TEAM PLUMBING, INC. | PB | P | 03/05/2018 | Low test, rest OK | SHANEN | SHANEN | | PB | P | 5780262 |