CLAYTON PROPERTIES GROUP II, INC. | B= | C | 07/06/2018 | | SCOTTS | SCOTTS | | B= | C | 5895204 |
CLAYTON PROPERTIES GROUP II, INC. | B= | P | 07/05/2018 | pin posts in basement -- window in basement incomplete -- unfinished basement/no deck -- Schedule a new Building Final when above items are complete. | SCOTTS | SCOTTS | | B= | P | 5893618 |
CLAYTON PROPERTIES GROUP II, INC. | BIN | C | 07/05/2018 | energy rating on file | SCOTTS | SCOTTS | | BIN | C | 5893359 |
CLAYTON PROPERTIES GROUP II, INC. | BFR | C | 04/26/2018 | corrections complete | SCOTTS | SCOTTS | | BFR | C | 5828307 |
CLAYTON PROPERTIES GROUP II, INC. | BFN | C | 04/26/2018 | foundation design on file | SCOTTS | SCOTTS | | BFN | C | 5827762 |
CLAYTON PROPERTIES GROUP II, INC. | BFR | R | 04/24/2018 | complete BFN/ missing coil strap and post on porch side of triple girder/can not see shear plate nailing | SCOTTS | SCOTTS | | BFR | R | 5825492 |
CLAYTON PROPERTIES GROUP II, INC. | BFR | T | 04/19/2018 | PAID (REC#1495655): house insulated prior to ok to insulate/can not see shear wall sill plates nailed down per schedule -- still missing coil straps per plan on T01X/HTS on porch wall/2nd H2.5 @ T02's rear wall //update// complete BFN | SCOTTS | SCOTTS | | BFR | T | 5821544 |
CLAYTON PROPERTIES GROUP II, INC. | BFR | R | 04/17/2018 | not dried in/missing windows -- nail down sill plates per schedule -- missing CS on ee of T01X -- missing 2nd H2.5 and HTS16's on porch wall -- missing 2nd H2.5 along T02A's/D's -- HHUS410 substituted for HUC410 w/titen screws -- isolate posts in basement -- missing 2x post at landing strap | SCOTTS | SCOTTS | | BFR | R | 5818919 |
CLAYTON PROPERTIES GROUP II, INC. | BFD | P | 04/17/2018 | provide foundation design/complete BFN -- engineering observations on file | SCOTTS | SCOTTS | | BFD | P | 5818514 |
CLAYTON PROPERTIES GROUP II, INC. | BFT | C | 04/17/2018 | soils report on file | SCOTTS | SCOTTS | | BFT | C | 5818513 |
CLAYTON PROPERTIES GROUP II, INC. | BFR | P | 04/17/2018 | structural set on file | SCOTTS | SCOTTS | | BFR | P | 5818407 |
CLAYTON PROPERTIES GROUP II, INC. | BIN | P | 04/16/2018 | Qualified third party energy inspection documentation must be presented at time of final building (B=) inspection | INTERNET | INTERNET | | BIN | P | 5818335 |
CLAYTON PROPERTIES GROUP II, INC. | BSP | P | 04/05/2018 | correction complete | SCOTTS | SCOTTS | | BSP | P | 5808615 |
CLAYTON PROPERTIES GROUP II, INC. | BSP | R | 03/23/2018 | hold down right side of garage door has 4"+ of spall/missing concrete at corner -- porch and post ok | SCOTTS | SCOTTS | | BSP | R | 5797418 |
CLAYTON PROPERTIES GROUP II, INC. | BSP | P | 03/23/2018 | structural set on file | SCOTTS | SCOTTS | | BSP | P | 5797113 |
CLAYTON PROPERTIES GROUP II, INC. | BFI | P | 02/12/2018 | AUTHORIZED INSPECTION BY ENGINEER | NELIDA | NELIDA | NELIDA | BFI | P | 5763624 |
CLAYTON PROPERTIES GROUP II, INC. | BFN | P | 02/12/2018 | AUTHORIZED INSPECTION BY ENGINEER | NELIDA | NELIDA | NELIDA | BFN | P | 5763623 |
J2D ELECTRIC, INC. | E= | C | 06/07/2018 | correction made | RANDY | RANDY | | E= | C | 5867998 |
J2D ELECTRIC, INC. | E= | R | 06/06/2018 | breaker #3 will not hold ----- see rough notes on ufer | TOMC | TOMC | | E= | R | 5866487 |
J2D ELECTRIC, INC. | ES | C | 04/05/2018 | Residential Underground: 150-amp 3 Wire service, ok to set meter / ---- NOTE ----- see rough comments on ufer | TOMC | TOMC | | ES | C | 5809225 |
J2D ELECTRIC, INC. | ER | C | 04/05/2018 | 150 --- 3 - #8 , no mcc , no central vac , unfinished basement ---- NOTE --- need concrete patch around ufer removed for inspection or engineer letter by final | TOMC | TOMC | | ER | C | 5809219 |
J2D ELECTRIC, INC. | ES | R | 04/04/2018 | Residential Underground: need to see ufer connection where mudded in | TOMC | TOMC | | ES | R | 5807589 |
J2D ELECTRIC, INC. | ER | R | 04/04/2018 | wires and boxes hanging outside walls in laundry and master closet , notch plate at bottom of stairs | TOMC | TOMC | | ER | R | 5807575 |
COMFORT CONTROL, INC. | H= | C | 07/03/2018 | | JEFFB | JEFFB | | H= | C | 5892455 |
COMFORT CONTROL, INC. | H= | P | 06/11/2018 | BASEMENT RETURN IS UNDERSIZED | MATTM | MATTM | | H= | P | 5869976 |
COMFORT CONTROL, INC. | H= | P | 06/01/2018 | CONDENSER PAD NEEDS TO BE SUPPORTED WITH CEMENT BLOCKS, PRESSURE TREATED 4X4, ETC., SECURE CONDENSATE DRAIN LINE, RETURN AIR IN BASEMENT IS UNDERSIZED, WATER HEATER VENT TERMINATION NEEDS SCREEN (SEE PAGE 32 FIGURE 32), NEED MANUFACTURE APPROVED VENT TERMINATION FOR FURNACE (SEE PAGE 61 FIGURE 52), NEED TO CONSULT WITH SENIOR MECHANICAL INSPECTOR ABOUT DRYER VENT, KITCHEN EXHAUST NEEDS TO BE COMPLETED OR CAPPED AND SEALED IN AN APPROVED MANNER NOTES: UNFINISHED BASEMENT (7 SUPPLY 1 RETURN 1 CAPPED FUTURE EXHAUST), OUTSIDE AIR TO FURNACE RETURN, A/C INSTALLED, DIRECT VENT FURNACE | MATTM | MATTM | | H= | P | 5862141 |
COMFORT CONTROL, INC. | HC | C | 04/16/2018 | RELEASE METER | DUSTINS | DUSTINS | | HC | C | 5818316 |
COMFORT CONTROL, INC. | HRR | C | 04/16/2018 | | DUSTINS | DUSTINS | | HRR | C | 5818315 |
COMFORT CONTROL, INC. | HRR | P | 04/13/2018 | INSULATE OUTSIDE AIR IN WALL ON MAIN LEVEL | BENH | BENH | | HRR | P | 5817167 |
COMFORT CONTROL, INC. | HRR | P | 04/11/2018 | need proper support to all ducts in attic. note: unfinished basement, outside air to return, direct vent furnace, indirect vent water heater, a/c rough and line set. | PAULO | PAULO | | HRR | P | 5814583 |
BLUE FLAME GAS COMPANY, INC. | HI | C | 04/04/2018 | 10LB test ok. 3/4" main line max out 1 furnace and 1 water heater | JEFFL | JEFFL | | HI | C | 5808109 |
COMFORT CONTROL, INC. | HRR | R | 03/29/2018 | Duct design not matching home. Furnace undersized by 20,000 BTU's. NOTES: Unfinished basement. Outside air to furnace return through roof. Direct vent furnace. A/C Rough coil and line-set. | RANDYB | RANDYB | | HRR | R | 5802283 |
B & L PLUMBING, INC. | P= | C | 06/11/2018 | correction made | TED | TED | | P= | C | 5870465 |
B & L PLUMBING, INC. | P= | P | 06/08/2018 | aav @ kitchen to be in vertical postion, uploaded image to complete, rest ok. note: pvb ok | JOHNS | JOHNS | | P= | P | 5869369 |
B & L PLUMBING, INC. | PTO | C | 03/30/2018 | unfinished basement, sprinkler stub | TED | TED | | PTO | C | 5803948 |
B & L PLUMBING, INC. | PB | C | 03/08/2018 | ok, water under footer | TED | TED | | PB | C | 5783766 |