CLAYTON PROPERTIES GROUP II, INC. | B= | C | 06/13/2018 | All other required Final inspections are complete. (This is a computer generated result) | SCOTTS | SCOTTS | | B= | C | 5873485 |
CLAYTON PROPERTIES GROUP II, INC. | B= | P | 06/12/2018 | unfinished basement/no deck. Additional Inspections Required (computer generated): External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: City Engineering Inspections 719-385-5977). | SCOTTS | SCOTTS | | B= | P | 5871895 |
CLAYTON PROPERTIES GROUP II, INC. | BIN | C | 06/12/2018 | energy rating on file | SCOTTS | SCOTTS | | BIN | C | 5871205 |
CLAYTON PROPERTIES GROUP II, INC. | BFR | C | 04/19/2018 | | SCOTTS | SCOTTS | | BFR | C | 5821023 |
CLAYTON PROPERTIES GROUP II, INC. | BFN | C | 04/19/2018 | foundation design on file | SCOTTS | SCOTTS | | BFN | C | 5821022 |
CLAYTON PROPERTIES GROUP II, INC. | BFR | R | 04/18/2018 | complete BFN -- frame corrections complete | SCOTTS | SCOTTS | | BFR | R | 5820421 |
CLAYTON PROPERTIES GROUP II, INC. | BFD | P | 04/17/2018 | provide foundation design/complete BFN -- engineering observations on file | SCOTTS | SCOTTS | | BFD | P | 5818519 |
CLAYTON PROPERTIES GROUP II, INC. | BFN | R | 04/17/2018 | provide foundation design | SCOTTS | SCOTTS | | BFN | R | 5818516 |
CLAYTON PROPERTIES GROUP II, INC. | BFT | C | 04/17/2018 | soils report on file | SCOTTS | SCOTTS | | BFT | C | 5818515 |
CLAYTON PROPERTIES GROUP II, INC. | BFR | R | 04/16/2018 | Missing window (not dried in ) // Tighten anchor bolts in garage // Missing roll blocking next to garage door // Missing (2) 2X4 stub post at girder end // foam and firestop // Rolling blocking corner of master bedroom // missing H2.5 above above window in kitchen // Missing nails in LUS28 at box out in basement ledger side // Missing roll blocking both beams in basement // nail down sill plates per shear schedule // Complete shear wall transfer detail 14 | NOAH | NOAH | | BFR | R | 5818225 |
CLAYTON PROPERTIES GROUP II, INC. | BSP | P | 04/16/2018 | inspection request changed to BSP / site specific framing on file / still need to perform frame inspection | LONNYS | LONNYS | | BSP | P | 5817324 |
CLAYTON PROPERTIES GROUP II, INC. | BIN | P | 04/16/2018 | Qualified third party energy inspection documentation must be presented at time of final building (B=) inspection | INTERNET | INTERNET | | BIN | P | 5817314 |
CLAYTON PROPERTIES GROUP II, INC. | BSP | P | 04/02/2018 | nail down sill plates per shear schedule -- install shear transfer on garage common wall per detail 14 -- hold downs and porch/post ok | SCOTTS | SCOTTS | | BSP | P | 5805363 |
CLAYTON PROPERTIES GROUP II, INC. | BFI | P | 02/12/2018 | AUTHORIZED INSPECTION BY ENGINEER | NELIDA | NELIDA | NELIDA | BFI | P | 5763643 |
CLAYTON PROPERTIES GROUP II, INC. | BFN | P | 02/12/2018 | AUTHORIZED INSPECTION BY ENGINEER | NELIDA | NELIDA | NELIDA | BFN | P | 5763642 |
J2D ELECTRIC, INC. | E= | C | 06/08/2018 | 25 amp a/c OK | CRAIGS | CRAIGS | | E= | C | 5868770 |
J2D ELECTRIC, INC. | ES | C | 04/12/2018 | Residential Underground: 150-amp 3 Wire service, ok to set meter / | TOMC | TOMC | | ES | C | 5815631 |
J2D ELECTRIC, INC. | ER | C | 04/12/2018 | 150 ---- 3 - #8 , no mcc , no central vac , irreversible ufer , unfinished basement | TOMC | TOMC | | ER | C | 5815596 |
COMFORT CONTROL, INC. | H= | C | 06/11/2018 | NOTES: UNFINISHED BASEMENT (4 SUPPLY 1 RETURN 1 FUTURE EXHAUST, OUTSIDE AIR TO FURNACE RETURN, DIRECT VENT FURNACE, A/C INSTALLED | MATTM | MATTM | | H= | C | 5870102 |
COMFORT CONTROL, INC. | HC | C | 04/13/2018 | RELEASE METER | BENH | BENH | | HC | C | 5817163 |
COMFORT CONTROL, INC. | HRR | C | 04/13/2018 | | BENH | BENH | | HRR | C | 5817148 |
BLUE FLAME GAS COMPANY, INC. | HI | C | 04/11/2018 | 10# test ok. note: 1" main at 90' to 1- furnace, 1- water heater and 1- fire place. | PAULO | PAULO | | HI | C | 5814594 |
COMFORT CONTROL, INC. | HRR | P | 04/11/2018 | need clearance to combustibles from fire place vent. note: unfinished basement, outside air to return, direct vent furnace, indirect vent water heater, a/c rough and line set. | PAULO | PAULO | | HRR | P | 5814593 |
B & L PLUMBING, INC. | P= | C | 05/29/2018 | unfinished basement, 3/4'' pvb installed | TED | TED | | P= | C | 5857670 |
B & L PLUMBING, INC. | PTO | C | 04/09/2018 | unfinished basement, sprinkler stub | TED | TED | | PTO | C | 5811669 |
B & L PLUMBING, INC. | PB | C | 03/09/2018 | | CALE | CALE | | PB | C | 5785111 |