CHALLENGER BUILDING, LLC | B= | C | 06/06/2018 | All other required Final inspections are complete. (This is a computer generated result) | SHAUN | SHAUN | | B= | C | 5866826 | CHALLENGER BUILDING, LLC | B= | P | 05/31/2018 | . Additional Inspections Required (computer generated): External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: City Engineering Inspections 719-385-5977). | SHAUN | SHAUN | | B= | P | 5860940 | CHALLENGER BUILDING, LLC | BIN | C | 04/30/2018 | | DALE | DALE | | BIN | C | 5830680 | CHALLENGER BUILDING, LLC | BFR | C | 04/27/2018 | eng. on file for post caps | DALE | DALE | | BFR | C | 5829069 | CHALLENGER BUILDING, LLC | BFR | P | 04/24/2018 | porch post caps are still BC4, need LPC4's / okay to insulate | BOBF | BOBF | | BFR | P | 5825838 | CHALLENGER BUILDING, LLC | BFR | P | 04/20/2018 | Tighten anchor bolts along perimeter of home // missing draftstop at main level bath tub // Need draft at both concealed space where Flex airduct is located (upstairs rec area) // Post cap at front porch still needs to be corrected. | NOAH | NOAH | | BFR | P | 5823023 | CHALLENGER BUILDING, LLC | BFT | C | 03/28/2018 | Engineers observation Letter on file / Soils report on file / 2000 psf / no drain required / 10% grade | DALE | DALE | | BFT | C | 5800807 | CHALLENGER BUILDING, LLC | BFN | C | 03/28/2018 | Engineers observation Letter on file / Eufer OK / Foundation design on file / | DALE | DALE | | BFN | C | 5800803 | CHALLENGER BUILDING, LLC | BSP | P | 03/27/2018 | complete bft bfn / narrow braced wall on exterior ok, check at frame interior sheathed at frame / porch post caps call for LPC4 has BC4 | DALE | DALE | | BSP | P | 5799806 | CHALLENGER BUILDING, LLC | BFI | C | 03/05/2018 | 2" foam insulation OK | DAKOTAB | DAKOTAB | | BFI | C | 5779838 | CHALLENGER BUILDING, LLC | BFD | P | 02/13/2018 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFD | P | 5763960 | CHALLENGER BUILDING, LLC | BFI | P | 02/13/2018 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFI | P | 5763961 | CHALLENGER BUILDING, LLC | BFT | P | 02/13/2018 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFT | P | 5763959 | CHALLENGER BUILDING, LLC | BFN | P | 02/13/2018 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFN | P | 5763958 | FOUNTAIN VALLEY ELECTRICAL, LLC | E= | C | 05/29/2018 | 30 amp a/c | RANDY | RANDY | | E= | C | 5858119 | FOUNTAIN VALLEY ELECTRICAL, LLC | E= | R | 05/25/2018 | house locked at 3:10 | RANDY | RANDY | | E= | R | 5856686 | FOUNTAIN VALLEY ELECTRICAL, LLC | ER | C | 04/19/2018 | 1-#6al, 2-10, irreversible ufer, slab, no vac, a/c stub | RANDY | RANDY | | ER | C | 5821872 | FOUNTAIN VALLEY ELECTRICAL, LLC | ES | C | 04/19/2018 | Residential Underground: 200 amp 3/w new res | RANDY | RANDY | | ES | C | 5821855 | COMFORT CONTROL, INC. | H= | C | 05/29/2018 | NOTE: OUTSIDE AIR TO FURNACE RETURN, 8" HIGH COMBUSTION AIR FROM VENTILATED ATTIC TO MECHANICAL ROOM, A/C INSTALLED. | DUSTINS | DUSTINS | | H= | C | 5857689 | COMFORT CONTROL, INC. | H= | P | 04/19/2018 | Duct leakage report received. | DUSTINS | DUSTINS | | H= | P | 5821036 | COMFORT CONTROL, INC. | HC | C | 04/18/2018 | RELEASE METER | LIDO | LIDO | | HC | C | 5820362 | COMFORT CONTROL, INC. | HRR | C | 04/18/2018 | Need duct leakage report by final . NOTES: 6" OUTSIDE AIR TO RETURN AIR , HIGH COMBUSTION AIR , AC COIL AND LINE SET ROUGH . | LIDO | LIDO | | HRR | C | 5820348 | L & L GAS SHOP, LLC. | HI | C | 04/05/2018 | 10 lb test ok. Notes-- 1'' main.. 1 furnace.. 1 water heater.. 1 fireplace.. | JEFFL | JEFFL | | HI | C | 5809369 | TEAM PLUMBING, INC. | P= | C | 05/30/2018 | PVB installed | CALE | CALE | | P= | C | 5859023 | TEAM PLUMBING, INC. | PTO | C | 04/17/2018 | corrections made | JOHNS | JOHNS | | PTO | C | 5819543 | TEAM PLUMBING, INC. | PTO | P | 04/16/2018 | low test @ mech room floor drain vent @ attic, need to strap this vent line as well, need removable and operable clearance @ t&p line, t&p to discharge 1 1/2" above flood level rim of the drain pan, strap per code vertical pex drops behind water htr, nail pro @ uppr hall bath vent and drain lines as well as hot line @ the tub and mstr shwr cold pex line, rest ok. note: vtr (3), slab, irrigation stub, tempering @ water htr | JOHNS | JOHNS | | PTO | P | 5818338 | TEAM PLUMBING, INC. | PB | C | 03/15/2018 | | CALE | CALE | | PB | C | 5790268 |
|
|