BLACK OAK HOMES & DESIGN, INC. | B= | C | 07/16/2018 | All other required Final inspections are complete. (This is a computer generated result) | TIMOTHYS | TIMOTHYS | | B= | C | 5904240 |
BLACK OAK HOMES & DESIGN, INC. | B= | P | 07/06/2018 | Covered rear deck with no stairs - Covered rear patio - AC installed. Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | TIMOTHYS | TIMOTHYS | | B= | P | 5894853 |
BLACK OAK HOMES & DESIGN, INC. | BLA | C | 05/09/2018 | | DALE | DALE | | BLA | C | 5840463 |
BLACK OAK HOMES & DESIGN, INC. | BIN | C | 04/27/2018 | | DALE | DALE | | BIN | C | 5829965 |
BLACK OAK HOMES & DESIGN, INC. | BIN | P | 04/26/2018 | need air barrier at basement at built walls | DALE | DALE | | BIN | P | 5828948 |
BLACK OAK HOMES & DESIGN, INC. | BFR | C | 04/26/2018 | front and rear porch frame and posts ok / narrow braced wall ok / deck under porch ok | DALE | DALE | | BFR | C | 5828887 |
BLACK OAK HOMES & DESIGN, INC. | BFR | P | 04/23/2018 | need 5 2x6 post under FX truss at garage / strap narrow braced wall / strap per detail at front wall detail / 2 H.2.5T on C series trusses / isolate all t-posts / front and rear connections covered before inspection / ok to insulate | DALE | DALE | | BFR | P | 5824657 |
BLACK OAK HOMES & DESIGN, INC. | BFT | C | 04/02/2018 | Engineers observation Letter on file / Soils report on file / foundation design / 3000 psf / drain usable / float 1 1/2" / 10% grade | DALE | DALE | | BFT | C | 5804661 |
BLACK OAK HOMES & DESIGN, INC. | BFN | C | 04/02/2018 | open hole / 3000 psf / drain usable / eng. drain observation and damp proofing observation | DALE | DALE | | BFN | C | 5804659 |
BLACK OAK HOMES & DESIGN, INC. | BFD | C | 04/02/2018 | eng. observation | DALE | DALE | | BFD | C | 5804657 |
BLACK OAK HOMES & DESIGN, INC. | BFD | P | 02/14/2018 | AUTHORIZED INSPECTION BY ENGINEER | NELIDA | NELIDA | NELIDA | BFD | P | 5766032 |
BLACK OAK HOMES & DESIGN, INC. | BFT | P | 02/14/2018 | AUTHORIZED INSPECTION BY ENGINEER | NELIDA | NELIDA | NELIDA | BFT | P | 5766031 |
BLACK OAK HOMES & DESIGN, INC. | BFN | P | 02/14/2018 | AUTHORIZED INSPECTION BY ENGINEER | NELIDA | NELIDA | NELIDA | BFN | P | 5766030 |
ELECTRIC TECH INC. | E= | C | 07/03/2018 | | JOSEPH | JOSEPH | | E= | C | 5892863 |
ELECTRIC TECH INC. | E= | T | 07/02/2018 | PAID (REC#1512986): Not ready corrections not made complete re-inspection. | JOSEPH | JOSEPH | | E= | T | 5891662 |
ELECTRIC TECH INC. | E= | R | 06/26/2018 | Complete re-inspection required. Following is a partial list only. ----- N.W. basement bedroom no power. ------ GFCI protection for garage ceiling outlets. ----- Laundry receptacle test/reset on GFCI can't be behind or above the appliance. ------- Blocking in mech room. ----- Add receptacle for circulation pump. ------- Where is dedicated circuit for exterior sump pump? ------ At AC disconnect use correct insulation on EGC. ------ Can't use deck screws for light in vault. ----- No power mech room receptacle. ---- Adjust dead front on panel. ----- Caulk all exterior outlets to keep water out. --- ID circuit # 6. ----- What type of breaker is circuit 6? ----- No open bulbs allowed in clothes closets. -- Master bathroom outlet in mirror is very loose. ----- Notes: 30 amp ac | JOSEPH | JOSEPH | | E= | R | 5886423 |
ELECTRIC TECH INC. | ER | C | 04/17/2018 | | JOSEPH | JOSEPH | | ER | C | 5819638 |
ELECTRIC TECH INC. | EUG | C | 04/16/2018 | | JOSEPH | JOSEPH | | EUG | C | 5817958 |
ELECTRIC TECH INC. | ES | C | 04/16/2018 | Residential Underground: 200 amp 3w new res ok to set meter | JOSEPH | JOSEPH | | ES | C | 5817957 |
ELECTRIC TECH INC. | ER | R | 04/16/2018 | Exhaust fans missing. ----------- Add outlet 1st floor corner of railing. ---------- Add light & receptacle in vault ---------- Notes: UFER is not IR -------- 120 volt central vac ------------ 10/3 ---- 6/3 cu | JOSEPH | JOSEPH | | ER | R | 5817956 |
COLORADO SPRINGS HEATING & COOLING SOLUTIONS, LLC | H= | C | 06/29/2018 | | NANCY | NANCY | | H= | C | 5889879 |
COLORADO SPRINGS HEATING & COOLING SOLUTIONS, LLC | H= | P | 06/28/2018 | CONDENSER NOT THREE INCHES ABOVE GRADE, PAD AND LINESET BURIED UNDER DIRT. PROVIDE FIREPLACE INSTALLATION INSTRUCTIONS, NEED TO VERIFY MANTLE CLEARANCE. CAP OR CONNECT GAS FLEX TO RANGE. NOTE: FINISHED BASEMENT. LOUVER DOOR TO MECHANICAL ROOM. OUTSIDE AIR TO FURNACE RETURN. A/C INSTALLED. DIRECT VENT FURNACE. | NANCY | NANCY | | H= | P | 5888483 |
DAVIS GAS SHOP INC | HO | C | 05/18/2018 | 10LB TEST OK. 75' OF 1 1/4" POLY PIPE WITH TRACER WIRE | BILLS | BILLS | | HO | C | 5849432 |
COLORADO SPRINGS HEATING & COOLING SOLUTIONS, LLC | HC | C | 04/20/2018 | RELEASE METER | RANDYB | RANDYB | | HC | C | 5822940 |
COLORADO SPRINGS HEATING & COOLING SOLUTIONS, LLC | HRR | C | 04/20/2018 | NOTES: Finished basement. Outside air to furnace return. Direct vent furnace. A/C Rough coil and line-set. | RANDYB | RANDYB | | HRR | C | 5822938 |
COLORADO SPRINGS HEATING & COOLING SOLUTIONS, LLC | HI | C | 04/19/2018 | 10 LB test ok. | DUSTINS | DUSTINS | | HI | C | 5821770 |
COLORADO SPRINGS HEATING & COOLING SOLUTIONS, LLC | HRR | P | 04/19/2018 | Supply air for basement bathroom needs dropped to faming. Need additional support in mechanical room for furnace vent per manufacturers installation instructions by final. NOTE: Outside air to furnace return, direct vent furnace, A/C rough coil and line set only, finished basement. | DUSTINS | DUSTINS | | HRR | P | 5821760 |
COLORADO SPRINGS HEATING & COOLING SOLUTIONS, LLC | HI | R | 04/18/2018 | Low test. 1 1/4" main. 1- furnace, 2- water heater, 1- range, 1- fireplace. | DUSTINS | DUSTINS | | HI | R | 5820390 |
COLORADO SPRINGS HEATING & COOLING SOLUTIONS, LLC | HRR | R | 04/18/2018 | Electric wire touching fire place vent. Some panning in basement is water damaged. Need furnace installation manual on site. Seal all return air penetrations in basement. More? Stopped inspection, re-inspect all. | DUSTINS | DUSTINS | | HRR | R | 5820383 |
BM PLUMBING INC | P= | C | 06/21/2018 | corrections made | JOSEPHD | JOSEPHD | | P= | C | 5881859 |
BM PLUMBING INC | P= | P | 06/20/2018 | toilet in LH basement bath loose, leak at 3" clean out in utility room, rest ok note: finished basement | JOSEPHD | JOSEPHD | | P= | P | 5880180 |
BM PLUMBING INC | PTO | C | 04/12/2018 | note: finished basement(2 bathrooms), aav @ both basement bath lavs, wet bar, laundry tub, | JOSEPHD | JOSEPHD | | PTO | C | 5815167 |
BM PLUMBING INC | PB | C | 03/02/2018 | | JOSEPHD | JOSEPHD | | PB | C | 5778740 |